FAR AV-6 Скачать руководство пользователя страница 4

FUNDAMENTAL ACOUSTIC RESEARCH

 

OWNERS MANUAL AV-6(C) 

4

 

 

TECHNICAL DESCRIPTION 

 

 

AV-6(C) 

Sensitivity dB 

SPL 

 

Maximum pressure level (2 cabinets @ 1 m) 

120 

 

 

 

Frequency Range 

Hz 

 

± 3 dB 

 

45-22000 

Low pass section 

 

 

Crossover frequency 

 

3500 Hz 24 dB/Octave 

Control 

 

-1dB/flat/+1dB/+2dB 

High pass section 

 

 

Crossover frequency 

 

6500 Hz 24 dB/Octave 

Control 

 

-3dB/-2dB/-1dB/flat/+1dB/+2dB 

Band pass filter 

 

20-20000 Hz 6 dB/Octave 

Limiter 

 

(on/off) +2dB 

 

 

 

Components  

 

Woofer 

 

21 cm / 8 inch 

Tweeter soft dome 

 

1 inch 

Содержание AV-6

Страница 1: ...FUNDAMENTAL ACOUSTIC RESEARCH OWNER S MANUAL ACTIVE MONITOR AV 6 C...

Страница 2: ...is owner s manual and use your speaker only in accordance with its instruction CONTENTS Applications 2 Installation 3 Technical description 4 Technical drawing 7 8 Fine frequency tuning 9 Limiter func...

Страница 3: ...cord immediately and consult an authorized FAR dealer Using the unit under such condition may cause a fire or shock hazard Installation Mains Attach the plug to the IEC socket And connect it to the m...

Страница 4: ...s 1 m 120 Frequency Range Hz 3 dB 45 22000 Low pass section Crossover frequency 3500 Hz 24 dB Octave Control 1dB flat 1dB 2dB High pass section Crossover frequency 6500 Hz 24 dB Octave Control 3dB 2dB...

Страница 5: ...TAL ACOUSTIC RESEARCH OWNERS MANUAL AV 6 C 5 Listening position cm 50 120 Amplifier Specifications Power PEAK W Tweeter Power 100 Woofer Power 180 Power NOMINAL W Tweeter Power 8 Ohm 70 Woofer Power 4...

Страница 6: ...Power bandwidth 20 25000 Hz Slew rate 35 V s SN ratio 100 dB Distortion Intermodulation 0 01 Total 0 05 Input Sensitivity 0 dB Impedance 10 kOhm Connectors Input symmetric XLR Jack Link XLR Remote RJ...

Страница 7: ...FUNDAMENTAL ACOUSTIC RESEARCH OWNERS MANUAL AV 6 C 7 TECHNICAL DRAWING...

Страница 8: ...z dB 0 200 500 5 8k 3 Hz dB TV CURVE TV MAINS FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE OF FUSE CAUTION REMOTE LINK Hz LOW PASS FILTER 0 dB Hz HIGH PASS FILTER dB 2...

Страница 9: ...es Figure 2 High pass section settings The dipswitch can be set to one of the six dB level positions for an optimum high frequencies setting Positions available 3 2 1 flat 1 2 dB Figure 1 high frequen...

Страница 10: ...on or off position using the dip switch on the rear panel Figure 3 limiter switch The overload LED indicates whether or not the limiter is in operation LED comes Red when the limiter is not in use Ora...

Страница 11: ...e That the remote control is not on mute position or 80 dB positions Sound is heard stronger from one side That the remote control is not on one side only That both level controls on the rear are corr...

Страница 12: ...identical to those perceived by the final users PRESET CURVES ACADEMY ACADEMY CURVE 0 10k 3 Hz dB 0 200 500 5 8k 3 Hz dB TV CURVE TV REMOTE LINK Figure 5 preset curves For the sound engineer this soun...

Страница 13: ...mall bad speaker in addition as you generally can see on the consoles The sound colour will obviously be the same as you use the same speaker for both curves The only one position will ensure you to h...

Страница 14: ...d of the curve you are working with Each led will light green Use the flat switch to work in flat frequency curve The led will light green Use the mute switch and the sound will be muted You can conne...

Отзывы: