Far East Europe CEFT54 Скачать руководство пользователя страница 18

WATER ON TOP COOKING RANGE (NATURAL GAS)

 

FAR EAST EUROPE LTD 

 

Service logbook 

Page 6 of 6 

 

16.

 

This guarantee is not transferable; if ownership of the cooker is transferred to another party or the 
cooker is moved to different premises, the guarantee is immediately voided. If a request for warranty or 
guarantee work is presented by a party or for a location other than that originally invoiced by Far East, 
Far East shall not be liable to that party. 

17.

 

 This guarantee is only applicable to cookers built after August 2012. 

18.

 

The cooker must be installed within the United Kingdom. Cookers installed in other countries will receive 
a 12 month parts only warranty only from Far East. 

19.

 

Only English language text in documentation and received in communications from us has legal standing. 
Any translations where provided and wherever human or computer generated are provided for 
convenience only and are not legally binding. Corresponds that Far East receives in languages other than 
English we may take to have legal standing and/or contractual agreement and obligation where no 
English translation has been provided by the sender. 

Содержание CEFT54

Страница 1: ...September 2015 Installations instructions and user guide Installation and user guide Water on Top Wok Cooking Range Natural Gas EUROPE LTD...

Страница 2: ...essary for the conversion The CEFT wok cooker can be supplied in several different configurations ranging from 5 front rings and 4 rear rings CEFT54 down to 1 single ring only with no rear burner CEFT...

Страница 3: ...1 cm depth It is important not to disturb the air combustion admission nor the combustion products evacuation of this appliance It is the kitchen supervisor s responsibility to warn users of this app...

Страница 4: ...er position Full Rate 15 55 21 90 kW 930 1470 BACK BURNER POSITIONS 2 Bar Burner Teknigas Full Rate 10 30 kW 2 Bar Burner Far East Full Rate 10 30 kW FRONT BURNER POSITIONS 3 Bar Burner Teknigas Full...

Страница 5: ...Spide r Reduced Rate 9 80 1 32 54 JP12 Phoenix 12 jet Full Rate 19 60 66 900 1 2 1 2 JP12 Phoenix 12 jet Reduced Rate 7 20 1 2 1 2 JP21 Phoenix 21 jet Full Rate 21 90 74 700 1 0 1 0 JP21 Phoenix 21 j...

Страница 6: ...urner pressure is reading 15 0 mbar For an ungoverned appliance ensure the correct nominal inlet pressure After setting the governor it must be sealed immediately and may not be adjusted by the user F...

Страница 7: ...UROPE LTD Installation instructions and user guide Page 6 of 10 COOKER DIMENSIONS 1370 35 930 340 410 N B 1 Therm 100 000 BTU hr 100 ft hr 1 000 BTU hr 1 Cu ft Incoming Main Normal Meter Size 1 5 550...

Страница 8: ...Replace the removable burners shelves etc in accordance with the drawing Connect the potable cold water supply to the spray rail and tap connect gas and waste pipe o The connection to potable cold wat...

Страница 9: ...ned to the ON position All pilot lights must be lit at all times The pilots should be lit even if the burner is not being used TURNING OFF THE BURNERS FOR SHORT PERIOD WHILST COOKING Turn the tap hand...

Страница 10: ...sive particles should not be used as the stainless steel will become damaged Items such as drip trays and burners can be removed for cleaning and should be replaced in reverse order making sure that t...

Страница 11: ...ugh cleaning program should ensure optimum performance and trouble free operation SERVICE CHECK We recommend that a Gas Safe registered engineer check the appliance at least every 12 months There is a...

Страница 12: ...st Europe Ltd No use may be made of its contents other than that expressly authorised Information correct at time of print subject to change without prior notice Guarantee and warranty and only applic...

Страница 13: ...rmocouples and 1x custom sized allen key for adjusting the valve handles These should be installed used by suitably qualified persons only COOKER DATA Model _______________ Serial No _______________ G...

Страница 14: ...siness name ______________________ Gas Safe Cert No ___________ SERVICE FOUR TO BE COMPLETED WITHIN 12 MONTHS OF PREVIOUS SERVICE I hereby confirm that the appliance has been serviced in accordance wi...

Страница 15: ...E NINE TO BE COMPLETED WITHIN 12 MONTHS OF PREVIOUS SERVICE I hereby confirm that the appliance has been serviced in accordance with the service checklist Date of service _____ _____ ______ Engineer s...

Страница 16: ...ICE FOURTEEN TO BE COMPLETED WITHIN 12 MONTHS OF PREVIOUS SERVICE I hereby confirm that the appliance has been serviced in accordance with the service checklist Date of service _____ _____ ______ Engi...

Страница 17: ...ediately void if any other party performs work on your cooker without our written consent 8 Any faults or defects must be reported to Far East within 3 working days of coming to the attention of the p...

Страница 18: ...is only applicable to cookers built after August 2012 18 The cooker must be installed within the United Kingdom Cookers installed in other countries will receive a 12 month parts only warranty only f...

Страница 19: ...INTENTIONALLY BLANK...

Страница 20: ...st Europe Ltd No use may be made of its contents other than that expressly authorised Information correct at time of print subject to change without prior notice Guarantee and warranty and only applic...

Отзывы: