Ethernet interface: standard RJ45 interface, 10/100M adaptive, it is recommended
to use five or five types of network cable
Description
Serial number
Two sets of short-circuit input detection interfaces: for connecting switches, infrared
probes, door magnets, vibration sensors and other input devices
Short circuit output 1: drive / short circuit output configurable
Short-circuit output 2: corresponding to the short-circuit input interface, login device
webpage setting, can be connected to the electric lock, alarm device, etc.
Wiegand interface
Two sets of door magnetic detection
Temperature control power interface: 12V/1A input
Power interface: 12V/1A input
JP1 jumper
ծ
JP1 Jumper
There are two modes for power supply of electric-lock as shown in the picture below.
(The default is “Passive Mode:”).
Passive Mode:
When the electric-lock starting current is more than 12V/500mA, need to use the
external drive mode, the electric lock interface for short circuit output control.
Active Mode :
When the electric-lock starting current is less than 12V/500mA, can use the internal
drive mode, the electric lock interface is 12V DC output.
+VNQFSJOQBTTJWFNPEF
+VNQFSJOBDUJWFNPEF
CN2
CN3
CN16
CN17
CN19
CN4