35
status. After changed, the status would be kept.
Initial Value is Monostable
Switch-On Duration
Door unlocking time for Monostable mode only. If the time is up, the
door would be locked automatically. Initial Value is 5 seconds.
Enable Card Reader
Enable or disable card reader for RFID cards.
Card Reader
Working Mode
Set ID card stats:
Normal: This is the work mode, after the slot card can to open the door.
Card Issuing: This is the issuing mode, after the slot card can to add ID
cards.
Card Revoking: This is the revoking mode, after the slot card can to
delete ID cards.
Card Reader HF
Card Data Reverse
Set the HF card data reverse order, the default value is automatic. You
can set it up when the card display is not consistent with the card
number.
Card Reader LF Card
Effective Data
The LF Card Effective Data, the default value is automatic.
Wiegand Data
Reverse
Set Wiegand Data Reverse, the default value is automatic.
Enable Access Table
Disable remote password implementations for all calls to open doors;
Enable remote password to open the door after calling only by access
guard
Limit Talk Duration
If enabled, calls would be forced ended after talking time is up.
Talk Duration
The call will be ended automatically when time up. Initial Value is 120
seconds
Calling Password
Remote door unlocking password. Initial Value is “*”.
Description
Device description displayed on IP scanning tool software. Initial Value
is “i33V IP Door Phone”.
Enable Open Log
Server
Enable or disable to connect with log server
Address of Open Log
Server
Log server address(IP or domain name)
Port of Open Log
Server
Log server port (0-65535) , Initial Value is 514.
Door Unlock
Indication
Indication tone for door unlocked. There are 3 type of tone: silent/short
beeps/long beeps.
Switch Mode
Monostable: there is only one fixed action status for door unlocking.
Bistable: there are two actions and statuses, door unlocking and door
locking. Each action might be triggered and changed to the other