IMPORTANT  SAFETY  INSTRUCTIONS

When using an electrical appliance, basic precautions should always be
followed, including the following.

                                         READ ALL INSTRUCTIONS

                        BEFORE USING THIS VACUUM CLEANER

WARNING -

 To reduce the risk of fire, electric shock or injury:

1. Do not leave the vacuum cleaner when plugged in. Unplug it from the outlet
    when not in use and before servicing.

2. Do not use outdoors or on wet surfaces.

3. Do not allow it to be used as a toy. Close attention is necessary when used
    by or near children or infirmed persons.

4. Use only as described in this manual. Use only the manufacturer's
    recommended attachments.

5. Do not use with a damaged cord or plug. If the vacuum cleaner is not working 
    as it should, or if it has been dropped, damaged, left outdoors or dropped into 
    water, return to FANTOM at 178 West Service Rd., Champlain, NY 12919.

6. Do not pull or carry by the cord, use the cord as a handle, close a door on the
    cord, or pull the cord around sharp edges or corners. Do not run the vacuum
    cleaner over the cord. Keep the cord away from heated surfaces.

7. Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.

8. Do not handle the plug or the vacuum cleaner with wet hands.

9. Do not put any objects into the openings. Do not use with any opening
    blocked: keep free of dust, lint, hair and anything that may reduce air flow.

10. Keep hair, loose clothing, fingers and all the parts of your body away from

    openings and moving parts.

11. Do not pick up anything that is burning or smoking, such as cigarettes,

    matches or hot ashes.

12. Do not use without dust compartment and filters in place.

13. Turn off all controls before unplugging.

14. Use extra care when cleaning on stairs.

15. Do not use to pick up flammable or combustible liquids such as gasoline, or

    use in areas where they may be present.

1

1

1

Содержание FM740

Страница 1: ...OF EACH PART PREPARATIONS BEFORE USE USING THE VACUUM CLEANER USING THE ATTACHMENTS EMPTYING THE DUST COMPARTMENT CLEANING THE FILTERS CLEANING THE SECONDARY FILTERS CLEARING BLOCKAGES AND CLEANING TH...

Страница 2: ...st Service Rd Champlain NY 12919 6 Do not pull or carry by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the vacuum cleaner over...

Страница 3: ...cleaner allow all metal parts to cool first 24 Always place foot on handle release when adjusting the handle position 25 If the supply cord of this appliance is damaged it must only be replaced by FA...

Страница 4: ...t the voltage specified on name plate Crevice Tool Release Button FRONT REAR Fork Handle Filter Cover Cord Storage Hooks Wand Power Cord Plug Plug shown in figure may differ from actual plug attached...

Страница 5: ...osition The handle screw has been installed for shipping purposes Remove the screw before inserting handle Insert the handle as shown in the illustration Insert the screw that you removed Be sure scre...

Страница 6: ...rewind the power cord INSERTING THE POWER CORD PLUG Plug shown in figure may differ from actual plug attached to unit for your area Upper Cord Storage Hook Plug Side Clip Holder Mount Hose Holder WARN...

Страница 7: ...l back on the handle until it releases from its upright position Upright position The handle is normally locked in this position for storage or when using the attachments Push the handle forward until...

Страница 8: ...ng brush To detach the dusting brush from the upholstery tool Press the tabs on the brush downward to remove it To reattach the dusting brush to the upholstery tool Insert the front of the upholstery...

Страница 9: ...e power cord from the wall outlet before cleaning Empty the dust compartment when contents reach the MAX mark Push the release button to remove the dust compartment Press the release lever to open the...

Страница 10: ...drop or damage the main filter and prefilter Clean the main filter and prefilter with a soft bristled brush and rinse with cold water Allow both items to dry completely Caution Do not use a hard brist...

Страница 11: ...yer to dry it Do not operate the vacuum without the sub filter Be sure the filter is dry and properly installed Failure to do so could result in electrical shock personal injury or motor failure CLEAN...

Страница 12: ...e is still blocked the suction force will be weak If the hose still appears to be blocked Set the vacuum cleaner to the parallel position and turn it over Remove the lower hose joint from the lower su...

Страница 13: ...n the screws to remove the lens 3 When removing the headlight lamp be careful not to pull on the headlight lamp wiring 4 Remove the lamp by pushing it gently in the direction of the arrow and then tur...

Страница 14: ...e refer to page 15 Lift out the agitator assembly and then remove the flat belt from the motor shaft and the agitator pulley Place a new flat belt onto the motor shaft and pulley Holding two ends of t...

Страница 15: ...ate refer to page 15 Lift out the agitator assembly and then remove the agitator assembly as shown Place the flat belt onto the pulley of the new agitator assembly Place the agitator assembly into the...

Страница 16: ...trated REATTACHING THE BOTTOM PLATE Insert the projection on the bottom place into the groove on the nozzle head and set the bottom plate in place Push the bottom plate as shown 4 Turn the vacuum over...

Страница 17: ...t compartment is full The suction hose is blocked The nozzle head is blocked The filters main filter pre filter and the secondary filters are dirty The agitator is dirty The motor does not operate whe...

Страница 18: ......

Отзывы: