14
Installation
CTI5 CONNECTION INTERFACE FOR C55 - C56 CHRONOSTATS
CTI5 interface connection to C55 or C56 chronostat.
Remove the chronostat body from the base.
Open the two knockdown slots on the chronostat body as shown in
the figure.
Snap-fasten the interface onto the chronostat. Take care to fit pro-
perly the female connector of the module onto the chronostat feet.
Fasten the thereby obtained unit onto the chronostat base.
Electric connections
If fixed installation with wiring under chase is required or if the cable
provided with jack plug is short, use another cable 3 x 0.5 mm2 with
20 m max. length. Connect one end to terminals 1 -2 - 3 of the ad-
ditional module and weld the jack plug as shown in the diagram. In
case of fixed installation only: open the knockdown area on the base
to friendly connect cables to terminal board.
Open the knockdown area
on the C55 / C56 base (for
fixed installation only)
Open the two knockdown
slots on the chronostat
Snap-fasten the module,
take care to fit the con
-
nector properly
*NOTE: NC = NOT
CONECTED
ALARM
INDICA-
TIONS
ELEC-
TRIC
CONSU-
MERS
EXTERNAL
BATTERY
POWER SUPPLY
CTI5 INTERFACE
C55 - C56 CHRO-
NOSTAT
Terminal
board
Jack plug