N L1 L
7
How to Wire Your Ceiling Fan
N
L1
L
Terminal Block
on Bracket
Fan
Wiring
220-240VAC
Household
Supply
LIVE
–
Red/Brown
Orange
NEUTRAL
–
Blue/Black
GRN/YEL–
Earth
Brown to Motor
Blue
Orange to Light
GRN/YEL
BLUE
–
To Motor N
BRN
–
To Motor L
GRN/YEL from hgr. ball
GRN/YEL from bracket
ORG
–
For Light
Figure 1
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a
licensed electrician.
NOTE: If fan or supply wires are different colors than indicated,
have this unit installed by a qualifi ed electrician.
CAUTION
To reduce the risk of fire and electrical shock, be sure
electricity is turned off before installing the wall control.
How to Wire and Operate Your CW40-220 Wall Control
NOTE: If fan or supply wires are different colors
than indicated, have this unit installed by a qualified
electrician.
1.
Installing Wall Control (Figures 1 & 2):
• With electrical power still disconnected, remove the
existing wall plate and switch.
• Make wiring connections to terminal block as shown in
Figure 1.
– One brown wire from wall control unit to red/brown
(hot supply).
– One brown wire from wall control unit to brown wire
leading to ceiling outlet box.
• Attach wall control unit to outlet box using the two
6-32 screws provided.
• Attach wall plate to the switch control front.
• Restore electrical power.
BRN
TO HOT
YEL/GRN from fan
YEL/GRN from bracket
220-240 VAC SUPPLY
(User Supplied)
Terminal Block
(on Hanger Bracket)
ORG-T
O LIGHT
BRN-T
O MOT
OR
BLUE-NEUTRAL
BRN
TO FAN
Figure 1
BLUE/BLK
(NEUTRAL)
RED/BRN
(HOT)
YEL/GRN
(EARTH)
Wall Control
(Rear View)
▲
WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not operate
fan until the blades are in place. Noise and fan damage
could result.
1.
Wiring the Fan (Figure 1):
• With electrical power still disconnected, remove the
existing wall plate and switch.
• Make wiring connections to terminal block as shown in
Figure 1.
– One green/yellow wire from hanger ball and
green/yellow wire from hanger bracket to the
terminal to green/yellow (earth/ground).
– One orange fan motor wire to the
L1
terminal to
orange (light).
– One blue fan motor wire to the
N
terminal to
blue (neutral).
– One brown fan motor wire to the
L
terminal to red/
brown (hot supply).
• Restore electrical power, after installing canopy housing
(see page 8).