How to Assemble Your Ceiling Fan

Pin

Setscrew

Hanger

Ball

Figure 1

1. 

Remove the Hanger Ball by loosening the setscrew 

in the Hanger Ball until the ball falls freely down the 
Downrod. (Figure 1)  Remove the Pin from the Downrod, 
then remove the Hanger Ball.  Retain the Pin and Hanger 
Ball for reinstallation in Step 5.

2. 

The fan comes with brown, blue, orange and green/

yellow 80˝ wires. Separate & untwist the three wires and 
safety cable. Route the wires through the downrod.

NOTE:  You will be using either the 6˝ downrod supplied with 
your fan or an optional downrod purchased separately.

3.

 Loosen the two setscrews in the Downrod Support.  Align 

the Clevis Pin holes in the Downrod with the holes in the 
Downrod Support.  Install the Clevis Pin and secure with 
the Hairpin Clip. (Figure 3)  Be sure to push the straight 
leg of the hairpin clip through the hole near the end of the 
clevis pin until the curved portion of the hairpin clip snaps 
around the clevis pin.  The hairpin clip must be properly 
installed to prevent the clevis pin from working loose. Pull 
on the Downrod to make sure the clevis pin is properly 
installed.

4. 

Route wires through Motor Coupling Cover, Canopy 

(with Canopy Screw Cover) on fan shown with open side 
facing up. (Figure 3)

5. 

Reinstall the Hanger Ball (Figure 1) on the Downrod 

as follows.  Route the three 80˝ wires and cable through 
the Hanger Ball.  Position the Pin through the two holes 
in the Downrod and align the Hanger Ball so the Pin is 
captured in the groove in the top of the Hanger Ball.  Pull 
the Hanger Ball up tight against the pin. 

Securely tighten 

the setscrew in the Hanger Ball.  A loose setscrew 
could create fan wobble.

6. 

While pulling up on the hanger ball, securely tighten the 

two setscrews with nuts in the downrod support. Slide the 
Motor Coupling Cover down on top of the motor housing.
(Figures 2 & 3)

7. 

Before installing fan, measure up approximately 6-9 

inches above top of Downrod/Hanger Ball Assembly.  Cut 
off excess wire and strip back insulation ½˝ from end of 
wire.

8. 

All set screws must be checked and retightened where 

necessary before installation.

9.

 You have now completed the upper assembly of your 

new ceiling fan.  You can now proceed with the hanging 
and the electrical wiring of your fan.

Clevis Pin

Motor
Coupling
Cover

Figure 2

Figure 3

Hairpin Clip

Downrod 

Support

WARNING

It is critical that the clevis pin in the downrod support 
is properly installed and the setscrews are securely 
tightened.  Failure to verify that the pin and setscrews 
are properly installed could result in the fan falling.

Setscrew (2)

Reverse 

Switch

5

Содержание The Zonix FP4620 220 Series

Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP4620 220 The Zonix Ceiling Fan Net Weight 9 07 kg 20 lbs ...

Страница 2: ...t vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or a defect LIMITED LIFETIME WARRANTY Extends to the original purchaser of a Fanimation Fan Important Safety Instructions WARNING To avoid fire shock and serious personal injury follow these instructions Table of Contents Unpacking Instructions 3 Energy Efficient Use of Ceiling Fans 4 Electric...

Страница 3: ...ew Cover Motor Coupling Cover Adapter Plate Lower Cover Assembly Wood Blades 3 CW40 220 Wall Control Adapter Plate Hardware Bags Fan Motor Assembly Lower Cover Assembly Downrod Hanger Ball Assembly Hanger Bracket One Phillips head screwdriver One stepladder One blade screwdriver One wire stripper Three wire connectors supplied Ceiling Canopy Blade Set Hardware bags 3 16 24 x 15 mm blade to motor h...

Страница 4: ...n doubt Electrical and Structural Requirements Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure efficient product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the flo...

Страница 5: ... Cover on fan shown with open side facing up Figure 3 5 Reinstall the Hanger Ball Figure 1 on the Downrod as follows Route the three 80 wires and cable through the Hanger Ball Position the Pin through the two holes in the Downrod and align the Hanger Ball so the Pin is captured in the groove in the top of the Hanger Ball Pull the Hanger Ball up tight against the pin Securely tighten the setscrew i...

Страница 6: ...gure 2 Outlet Box Hanger Bracket Outlet Box Hanger Bracket Screw 2 Supplied with Outlet Box Tab Downrod Hanger Ball Assembly WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible shock do not pinch wires between the downrod hanger ball assembly and the hanger bracket 1 Securely attach the hanger bracket to the outle...

Страница 7: ...ed brown hot supply One brown wire from wall control unit to brown wire leading to ceiling outlet box Attach wall control unit to outlet box using the two 6 32 screws provided Attach wall plate to the switch control front Restore electrical power BRN TO HOT YEL GRN from fan YEL GRN from bracket 220 240 VAC SUPPLY User Supplied Terminal Block on Hanger Bracket ORG TO LIGHT BRN TO MOTOR BLUE NEUTRAL...

Страница 8: ... the Canopy Housing Figure 1a Figure 1b NOTE This step is applicable after the necessary wiring is completed WARNING To avoid possible fire or shock make sure that the electrical wires are completely inside the canopy housing and not pinched between the housing and the ceiling 1 Loosen the two shoulder screws in the Hanger Bracket 2 Securely attach the Canopy Housing over the shoulder screws Figur...

Страница 9: ...ttach the Switch Cup Support Plate to the support flange by rotating plate and properly positioning screws in key slots Install fourth screw in remaining hole Fully tighten all four screws Figure 5 Figure 4 Fan Blade Figure 2 Washer Head Screw with Fiber Washer 3 per blade INSTALLATION NOTE Do not connect fan blades until the fan is completely installed Installing the fan with blades assembled may...

Страница 10: ...fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish CAUTION Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of electrical shock Blade Cleaning Periodic light dustin...

Страница 11: ...h other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not recommended choose an alternative control method 6 Tighten lock nuts securely 7 Tighten set screw securely 3 FAN WOBBLES EXCESSIVELY 1 Setscrew in downrod support is loose 2 Setscrew in...

Страница 12: ...or Assembly AMA4620 220 7 Switch Cup Cover Assembly with Flat Head Screws 3 AP462010 8 Blade Set 3 AP442007 9 Wall Control CW40 220 10 Hardware Bag Containing HDWFP4620 Blade Balance Kit BALKT HDWHW4620 Wire Connectors 4 Blade Mounting Hardware Bag Containing HDWBM4620 3 16 24 x 15 mm Washer Head Screw 10 Fiber Washers 10 Phillips Screwdriver 4 How To Order Parts When ordering repair parts always ...

Страница 13: ...Zonix Model FP4620 220 Exploded View 1 3 4 2a 2b 2c 2d 2 7 NOTE The illustration shown is not to scale or its actual configuration may vary Product parts are subject to change without notice Figure 1 8 10 9 13 ...

Страница 14: ...Copyright 2008 Fanimation 2009 04 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com ...