Fanimation MAD3250 series Скачать руководство пользователя страница 2

1.   LIMITED LIFETIME MOTOR WARRANTY - If any part of your fan motor fails, due to a defect in materials or workmanship during 
the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned
to our national service center.  Proof of purchase is required.  Customer shall be responsible for all costs incurred in the removal or 
reinstallation and shipping of the product for repairs or replacement.
2.   ONE YEAR MOTOR LABOR WARRANTY - If your fan motor fails at any time within one year from the original purchase, due to 
defects in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center.  Purchaser 
will be responsible for labor charges after this one-year period.  Customer shall be responsible for all costs incurred in the removal or 
reinstallation and shipping of the product for repairs or replacement.
3.   If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we 
will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.
4.   Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding,
tarnishing, or peeling.
5.  This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of 
heat or humidity, or as a result of any modification to the original product.
6.   All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan 
or Fanimation.
7.   Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.
8.   Under no circumstances may a fan be returned without prior authorization from Fanimation.  The receipt of purchase must ac-
company authorized returns and must be sent freight prepaid to Fanimation.  The fan to be returned must be properly packed to avoid
damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging.
9.   It is understood that any repair or replacement is the exclusive remedy available from Fanimation.  There is no other expressed or 
implied warranty.  Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and 
fitness for a particular purpose to the extent permitted by law.  Some states do not allow limitations on implied warranties.  Fanimation
will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance,
except as may otherwise be accorded by law.  This warranty gives you special legal rights and you may also have other rights that vary 
from state to state.
10. A certain amount of wobble is normal and should not be considered a problem or a defect.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

Important Safety Instructions

WARNING: To avoid fire, shock and serious personal injury, follow these instructions.

1.   Read your owner’s manual and safety information before installing your new fan.  Review the accompanying assembly diagrams.
2.   Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power 
from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a warning device, such
as a tag, to the service panel.
3.   Be careful of the fan and blades when cleaning, painting, or working near the fan.  Always turn off the power to the ceiling fan before 
servicing.
4.   Do not insert anything into the fan blades while the fan is operating.
5.   Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions

1.   To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2.   All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70-1999) and Local Codes.  The ceiling fan 
must be grounded as a precaution against possible electrical shock.  Electrical installation should be made or approved by a licensed
electrician.
3.   The fan base must be securely mounted and capable of reliably supporting at least 35 lbs.  Consult a qualified electrician if in doubt.
4.   The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
5.   Follow the recommended instructions for the proper method of wiring your ceiling fan.  If you do not have adequate electrical
knowledge or experience, have your fan installed by licensed electrician.

WARNING:

  TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS FAN MUST BE INSTALLED WITH A GENERAL USE, 

ISOLATING WALL CONTROL/ SWITCH.

WARNING:

  This product is designed to use only those parts supplied with this product and/or accessories designated specifically for 

use with this product.  Using parts and/or accessories not designated for use with this product could result in personal injury or property 
damage.

WARNING:

  To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the brackets, 

balancing the blades, or cleaning the fan.  Do not insert foreign objects in between rotating fan blades.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation. If the intentional radiator can be classified as a Class B digital device or a PC 
peripheral, then shall include the following or equivalent:

Note:

 This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna. 
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help. 

Note:

 For a Class A digital device, statements of 15. 105(a) must be included when appropriate for the device in question.

6.   Suitable for use with solid-state speed controls.

Содержание MAD3250 series

Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS The Islander Ceiling Fan Net Weight 6 37 kg 14 04 lbs Model No MAD3250 R...

Страница 2: ...f at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning devic...

Страница 3: ...w to Assemble Your Ceiling Fan 7 How to Hang Your Ceiling Fan 9 How to Wire Your Ceiling Fan 10 Installing the Canopy Housing 11 How to Operate Your Ceiling Fan 13 Assembling and Mounting the Fan Blad...

Страница 4: ...U Four wire connectors supplied WARNING Do not install or use fan if any part is damaged or missing This product is designed to use only those parts supplied with this product and or any accessories d...

Страница 5: ...gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realize...

Страница 6: ...box with brace Figure 3 Paired with a deep box this hanger is meant to span between two joists and takes the place of wooden blocking To avoid fire or shock follow all wiring instructions carefully A...

Страница 7: ...e l c e h t n g i l A r e l p u o c o t n i d o r n w o d l l a t s n I holes in the downrod with the holes in the downrod support Figure 2 3 Install the clevis pin hairpin clip and tighten set screw...

Страница 8: ...and retightened where necessary before installation Canopy Screw Cover Ceiling Canopy Motor Coupling Cover Figure 4 Figure 5 5 Reinstall the hanger ball on the downrod as follows Route the two 80 in...

Страница 9: ...ll pass through the washer safety cable loop and into the building structure Figure 9 NOTE Ceiling support cable cannot be secured to junction box only it must be directly secured to ceiling joist or...

Страница 10: ...Ground Listed Outlet Box Household Supply Black Wire from Supply Black Wire from Fan x 3 WIRE CONNECTORS HARDWARE USED NOTE If you feel that you do not have enough electrical wiring knowledge or expe...

Страница 11: ...and Mounting the Fan Blades Do not connect fan blades until the fan is completely installed Installing the fan with blades assembled may result in damage to the fan blades CAUTION x 10 3 16 24 x 10 m...

Страница 12: ...ure the screws with lockwashers securing the blade holders to the fan motor hub are tight and that the blade holders are properly seated Figure 16 Figure 17 Switch Housing Cup Assembly 3 Disassemble t...

Страница 13: ...remote away from excessive heat or humidly Figure 21 NOTE Receiver in controllers system features an automatic learning function There are no frequency switches on the receiver unit The receiver will...

Страница 14: ...dium low speed IV medium speed V medium high speed VI high speed Button This button turns the fan off Reverse button This button is to control fan direction The button is to control light Infinite lig...

Страница 15: ...EO 3 Canopy 1 DQJHU UDFNHW 6FUHZ VVHPEO CDQRS 6FUHZ RYHU VVHPEO 4 0RWRU RXSOHU RYHU VVHPEO 5 0RWRU VVHPEO 6 ODGH ROGHU RYHU 6HW 7 ODGH ROGHU 6HW 8 9 10 6ZLWFK RXVLQJ DS VVVHPEO Remote Hand Held ADR1 6...

Страница 16: ...NOTE The illustration shown is not to scale or its actual parts configuration may var y Exploded View Illustration 16 MAD3250 3 4 5 6 9 7 11 8 1 10 2 12...

Страница 17: ...ommended choose an alternative control method 6 Tighten screws securely 3 FAN WOBBLES EXCESSIVELY 1 Setscrew and nut in downrod support is loose 2 Setscrew in downrod hanger ball assembly is loose 3 S...

Страница 18: ...Copyright 2014 Fanimation 2014 03 V 01 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Страница 19: ...Ventilador de techo Peso neto 6 37 kg 14 04 lb MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES Modelo N MAD3250 The Islander R...

Страница 20: ...onales Para evitar posibles descargas el ctricas aseg rese de que la electricidad est desconectada en la caja de fusibles antes de realizar 1 la instalaci n el ctrica y no haga funcionar el ventilador...

Страница 21: ...os no permiten limitaciones sobre las garant as impl citas Fanimation no se har responsable por da os accidentales resultantes o especiales derivados del uso o el rendimiento del producto o en conjunc...

Страница 22: ...los conocimientos el ctricos necesarios contrate a un electricista autorizado para instalar el ventilador LD FDMD GH GLVWULEXFLyQ HO FWULFD ORV FRQHFWRUHV GH OD FDMD GHEHQ VHU GHO WLSR UHTXHULGR SRU H...

Страница 23: ...tinuaci nlepresentamosalgunassugerencias para asegurar un rendimiento eficiente del producto Selecci n del lugar de montaje adecuado Los ventiladores de techo se deben instalar en el centro de la habi...

Страница 24: ...a autorizado ADVERTENCIA Apagar el interruptor de pared no es suficiente Para evitar posibles descargas el ctricas aseg rese de que la electricidad est desconectada en la caja de fusibles principal an...

Страница 25: ...os orificios del soporte del mismo Figura 2 3 Instale el pasador y el pasador de horquilla y apriete los tornillos de fijaci n El pasador y el pasador de horquilla deben estar instalados correctamente...

Страница 26: ...Se deben revisar todos los tornillos de fijaci n y volver a ajustarlos cuando sea necesario antes de realizar la instalaci n Figura 5 5 Vuelva a colocar la semiesfera en el barral como se indica a con...

Страница 27: ...la leng eta de la abrazadera para colgar Figura 10 NOTA el cable de soporte para techo no se puede asegurar solamente a la caja de conexiones se debe asegurar directamente a la viga de techo o miembro...

Страница 28: ...ue todas las conexiones est n ajustadas incluida la conexi n a tierra y que no haya conductores desnudos visibles en los conectores excepto el conductor con conexi n a tierra No opere el ventilador ha...

Страница 29: ...NOTA Encontrar que la pala del ventilador viene empaquetada en su propio envoltorio de cart n y que las sujeciones de las palas y la bolsa del hardware vienen en la caja del ventilador Cubierta del so...

Страница 30: ...los tres tornillos del soporte ubicado en la parte inferior de la unidad del motor Afloje levemente los otros dos tornillos Instale la unidad de la placa de luz en el soporte utilizando las dos ranur...

Страница 31: ...de aprendizaje autom tico No hay interruptores de frecuencia en la unidad del receptor El receptor ya que se escanear autom ticamente la frecuencia desde el mando a distancia si se realiza cualquier c...

Страница 32: ...ON es la selecci n regulable de luz y debe ser utilizada con todas las bombillas menos con las bombillas CFL La selecci n D es la encender solo la luz sin la funci n de regulaci n y debe ser utilizada...

Страница 33: ...ho Podr an da ar el motor o las aspas y ocasionar posibles descargas el ctricas SE RECOMIENDA veri car peri dicamente que los tornillos que sujetan los soportes de aspas al buje del motor est n bien a...

Страница 34: ...zas Destornillador Phillips de 4 Antes de desechar los materiales de embalaje aseg rese de haber extra do todas las piezas Inserte los C DIGOS DE ACABADO consulte el n mero de modelo del ventilador qu...

Страница 35: ...3 4 5 6 9 7 11 8 1 10 2 12 35 MAD3250 NOTA la ilustraci n que se muestra no est hecha a escala y su con guraci n real puede variar Ilustraci n del Despiece...

Страница 36: ...no son recomendables Escoja un m todo de control alternativo 6 Ajuste bien los tornillos 3 EL VENTILADOR OSCILA EN EXCESO 1 El tornillo de fijaci n y la tuerca del soporte de barral est n flojos 2 El...

Страница 37: ...014 Fanimation 2014 03V 01 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fan...

Отзывы: