background image

.

Table of Contents

Unpacking Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical and Structural Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Wiring and Control Options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
How to Set and Operate Your C24 Hand-held Remote. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
How to Set and Operate Your C25 Wireless Wall Control  . . . . . . . . . . . . . . . . . . . . . . . . . 6
Hanger Options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Hanging the Fan  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring Your Ceiling Fan - Hanger Canopy Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wiring Your Ceiling Fan - Hanger Eye Bolt Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
How to Install Your Light Kit - LK27 (Optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Installing the Shades. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
How to Change Your Light Bulbs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Exploded-View Drawing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

1.   LIMITED LIFETIME MOTOR WARRANTY - If any part of your fan motor fails, due to a defect in materials or workmanship during 
the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned 
to our national service center.  Proof of purchase is required.  Customer shall be responsible for all costs incurred in the removal or 
reinstallation and shipping of the product for repairs or replacement.
2.   ONE YEAR MOTOR LABOR WARRANTY - If your fan motor fails at any time within one year from the original purchase, due to 
defects in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center.  Purchaser 
will be responsible for labor charges after this one-year period.  Customer shall be responsible for all costs incurred in the removal or 
reinstallation and shipping of the product for repairs or replacement.
3.   If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we 
will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.
4.   Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding, 
tarnishing, or peeling.
5.  This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of 
heat or humidity, or as a result of any modification to the original product.
6.   All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan 
or Fanimation.
7.   Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.
8.   Under no circumstances may a fan be returned without prior authorization from Fanimation.  The receipt of purchase must ac-
company authorized returns and must be sent freight prepaid to Fanimation.  The fan to be returned must be properly packed to avoid 
damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging.
9.   It is understood that any repair or replacement is the exclusive remedy available from Fanimation.  There is no other expressed or 
implied warranty.  Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and 
fitness for a particular purpose to the extent permitted by law.  Some states do not allow limitations on implied warranties.  Fanimation 
will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance, 
except as may otherwise be accorded by law.  This warranty gives you special legal rights and you may also have other rights that vary 
from state to state.
10. A certain amount of wobble is normal and should not be considered a problem or a defect.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

Additional Safety Instructions

Important Safety Instructions

WARNING: To avoid fire, shock and serious personal injury, follow these instructions.

1.   To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2.   All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70-1999).  Use the National Electrical Code 
if Local Codes do not exist.  The ceiling fan must be grounded as a precaution against possible electrical shock.  Electrical installation 
should be made or approved by a licensed electrician.
3.   The fan base must be securely mounted and capable of reliably supporting at least 100 lbs (45.36 kg). (fan and accessories not to 
exceed 35 lbs. or 16 kgs.).  Outlet boxes are not acceptable for fan support.  See page 4 of owner’s manual for support requirements.  
Consult a qualified electrician if in doubt.
4.   

CAUTION:

  To reduce the risk of personal injury, mount the fan base to a ceiling joist or structural member using the hardware 

provided with your fan.

WARNING:

  Support Directly from Building Structure.

5.   The fan must be mounted at least 7 feet from the floor to prevent accidental contact with the fan blades.
6.   Follow the recommended instructions for the proper method of wiring your ceiling fan.  If you do not have adequate electrical 
knowledge or experience, have your fan installed by licensed electrician.
7.   Suitable for use with solid-state speed controls.

WARNING:

  To reduce the risk of fire or electric shock, this fan should only be used with Fan Speed Control Part No. UC7074R, 

manufactured by Rhine Electronic Co., Ltd.

WARNING:

  TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL CONTROL/SWITCH.

WARNING:

  This product is designed to use only those parts supplied with this product and/or accessories designated specifically for 

use with this product.  Using parts and/or accessories not designated for use with this product could result in personal injury or property 
damage.

WARNING:

   Do not insert foreign objects in between rotating fan blades.

1.   Read your owner’s manual and safety information before installing your new fan.  Review the accompanying assembly diagrams.
2.   Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power 
from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a warning device, such 
as a tag, to the service panel.
3.   Be careful of the fan and blades when cleaning, painting, or working near the fan.  Always turn off the power to the ceiling fan before 
servicing.
4.   Do not insert anything into the fan blades while the fan is operating.

Содержание Evanesce FP2700 Series

Страница 1: ...NUAL READ AND SAVE THESE INSTRUCTIONS Model No FP2700 Series The Evanesce Ceiling Fan Suitable for use with Solid State Speed Controls WARNING Support Directly From Building Structure Net Weight 75 lb...

Страница 2: ...permitted by law Some states do not allow limitations on implied warranties Fanimation will not be liable for incidental consequential or special damages arising out of or in conjunction with product...

Страница 3: ...fer to exploded view illustration Figure 18 page 13 Check to see that you have received the following parts Evanesce Fan Assembly Hanger Canopy Assembly 80 Chains 2 8 Hanger Rods 4 Hanger Eye Bolts 2...

Страница 4: ...nd Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock If your fan is to replace an existing light fixture turn electricity off at the main fuse...

Страница 5: ...s to the same positions as set on your receiver Figure 3 Replace battery cover on the transmitter 1 Operating Using Remote Transmitter Figure 4 Install 9 volt battery If not using for long periods of...

Страница 6: ...ovided Attach wall plate to the switch control front using the two small screws provided Restore electrical power NOTE In case of weak reception replace battery inside wall control 6 Operating Using W...

Страница 7: ...on 1 Hanger Canopy Mount Figure 8a 1 Place the Hanger Canopy Assembly on the ceiling covering the junction box 2 Attach the assembly to the ceiling using two 5 Lag Bolts Choose any 2 opposing holes in...

Страница 8: ...lack wire from the fan to the black wire in the junction box 7 Attach the white wire from the fan to the white wire in the junction box 8 Attach the green wire from the fan to the green wire in the ju...

Страница 9: ...off any excess lead wire 7 Strip the Black White and Green wires so that inch of bare wire is revealed 8 Attach the black wire from the fan to the black wire in the junction box 9 Attach the white wi...

Страница 10: ...es are not pinched between the cover and the fan assembly Do not over tighten 6 Re install Rubber Plug 7 Install optional shades and light bulbs not included 8 Restore power 9 See pages 5 6 to operate...

Страница 11: ...an is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive and or non abrasive cleaning agents are not required and should...

Страница 12: ...Lag Eye Bolt 2 13 S Hook 4 HDWSH2700 14 8 Hanging Rod 4 HDWHR2700 15 Remote Control 1 C24 16 Wireless Wall Control 1 C25 Before discarding packaging materials be certain all parts have been removed Pa...

Страница 13: ...OTE The illustration shown is not to scale or its actual configuration may vary Wires partially removed for clarity Parts Illustration 7 6 11 13 14 9 10 16 5 4 3 2 The Evansece FP2700 Optional Sold Se...

Страница 14: ...ontrol 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in the switch housings CAUTION Make sure main power is turned off 3 Re...

Страница 15: ......

Страница 16: ...10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com Copyright 2006 Fanimation 2006 02...

Отзывы: