Electrical and Structural Requirements

Your new ceiling fan will require a grounded electrical 
supply line of 120 volts AC, 60 Hz, 15 amp circuit.  The 
outlet box must be securely anchored and capable of 
withstanding a load of at least 50 lbs.  Figure 1 depicts 
different structural con

fi

 gurations that may be used for 

mounting the outlet box.

If your fan is to replace an existing light 

fi

 xture,  turn 

electricity off at the main fuse box at this time and remove 
the existing light 

fi

 xture.

1.   

To prevent damage to housing and/or blade, leave 

the Ceiling Fan Assembly in its original packing during 
installation of lower cover assembly, down rod, ceiling 
canopy and motor coupling cover.

NOTE: 

 Do not set Ceiling Fan Assembly on 

fl

 oor or hard 

surface.

2.

  Prior to assembly, set aside and save the hardware 

bag(s) packed in the packing.

3.

  Assemble the Lower Cover Assembly by connecting 

the 2-pin (black & white wires) socket connector to 
the plug connector (blue & white wires). Be sure the 
connector wires are inside the Control Housing before 
assembling the Lower Cover Assembly. (Figure 1)

4.

  Locate and loosen two Indexing Screws located on the 

Control Housing. (Figure 1)  Line up the indexing holes 
over the screws, secure by twisting the Lower Cover 
Assembly clockwise and tighten the two indexing screws. 
(Figure 2)

5.

  Turn the Ceiling Fan Assembly (in package) top-side 

up for installing down rod, ceiling canopy and motor 
coupling cover.

How to Assemble Your Ceiling Fan

Figure 1

Control 

Housing

Index Screw (2 places)

2-pin 

connector

2

˝

 x 4

˝

Ceiling

Joists

Ceiling

Outlet

Box

Figure 1

WARNING

To avoid fire or shock, follow all wiring instructions 

carefully.  Any electrical work not described in these 

instructions should be done or approved by a licensed 

electrician.

WARNING

Turning off wall switch is not sufficent.  To avoid 

possible electrical shock, be sure electricity is turned 

off at the main fuse box before wiring.  All wiring must 

be in accordance with National and Local codes and the 

ceiling fan must be properly grounded as a precaution 

against possible electrical shock.

Figure 2

Indexing 

Holes

(2 places)

WARNING

To reduce the risk of fire, electrical shock, or personal 

injury, mount fan to outlet box marked acceptable 

for fan support of 22.7 kg (50 lbs) or less. Use screws 

supplied with outlet box.  Most outlet boxes commonly 

used for support of light fixtures are not acceptable for 

fan support and may need to be replaced.  Consult a 

qualified electrician if in doubt.

Содержание Enigma FP2120 Series

Страница 1: ...Enigma Ceiling Fan Suitable for use with Solid State Speed Controls WARNING Support Directly From Building Structure Net Weight 38 lbs or 17 3 kg For Canada this fan must be secured directly to the b...

Страница 2: ...onjunction with product use or performance except as may otherwise be accorded by law This warranty gives you special legal rights and you may also have other rights that vary from state to state 10 A...

Страница 3: ...32 threaded rods Two 5 32 lockwashers Two 5 32 knurled knobs Support Cable bag Ceiling Support Cable Cable Clamp x 2 lag bolt flat washer Lower Cover Assembly Lower Cap C4 Fan Light Remote Control Rem...

Страница 4: ...Control Housing Figure 1 Line up the indexing holes over the screws secure by twisting the Lower Cover Assembly clockwise and tighten the two indexing screws Figure 2 5 Turn the Ceiling Fan Assembly...

Страница 5: ...e straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed...

Страница 6: ...an be made later 4 Carefully lift the fan and seat the downrod hanger ball assembly on the hanger bracket that was just attached to the ceiling joist Be sure the groove in the ball is lined up with ta...

Страница 7: ...not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician 2 Installing Receiver in Hanger Bracket Slide remote Receiver into the Hanger Bracket Figure...

Страница 8: ...page 7 NOTE Supply wires and fan wires omitted for clarity 1 To install lower cap screw in lower cap into bulb socket until tight Figure 3 3 Restore power Figure 2 WARNING To avoid possible fire or s...

Страница 9: ...tch wire connections in the switch housing 3 Dead battery in remote control 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections i...

Страница 10: ...eaded Rods 2 5 32 External Lockwashers 2 Knurled Knobs 2 Wire Connectors 3 Support Cable Bag Containing HWBSCABLE Ceiling Support Cable Cable Clamp Flat Washer x 2 Lag Bolt 9 Receiver Unit RECAN34 10...

Страница 11: ...2a 2b 2c 2d 2 8 7 6 4 5 3 9 1 10 11 NOTE The illustration shown is not to scale or its actual configuration may vary Wires partially removed for clarity Exploded View The Enigma FP2120 Figure 1...

Страница 12: ...10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Visit Our Website www fanimation com Copyright 2007 Fanimation 2007 08...

Отзывы: