27
1.
Check main and branch circuit fuses or circuit breakers.
2.
Check line wire connections to fan and switch wire
connections in the switch housings.
CAUTION: Make sure main power is turned off !
CAUTION: Make sure main power is turned off !
3.
Replace with fresh battery.
1.
Attach blades to fan before operating.
2.
Check to make sure all screws in motor housing are
snug (not over-tight).
3.
Check to make sure wire connectors in switch housing
are not rattling against each other or against the interior
wall of the switch housing.
4.
Some fan motors are sensitive to signals from solid-state
variable speed controls. Solid-state controls are not
recommended, choose an alternative control method.
1.
Tighten both setscrews securely in downrod support.
2.
Tighten the setscrew in the downrod/hanger ball
assembly.
3.
Check to be sure screws which attach the fan blade
to the motor assembly are tight.
4.
Tighten the hanger bracket screws to the outlet box,
and secure outlet box.
1.
If possible, consider using a longer downrod (not
included, you can buy the longer downrod from
fanimation.com).
1. FAN WILL NOT START.
2. FAN SOUNDS NOISY.
3. FAN WOBBLES
EXCESSIVELY.
5. NOT ENOUGH AIR
MOVEMENT.
4. REMOTE CONTROL
DOES NOT WORK. THE
CONTROL INDICATOR
LED IS CONSTANTLY
FLASHING.
1.
Fuse or circuit breaker blown.
2.
Loose power line connections to the fan, or loose
switch wire connections in the switch housing.
3.
Dead battery in remote control.
1.
Blades not attached to fan.
2.
Loose screws in motor housing.
3.
Wire connectors inside housing rattling.
4.
Motor noise caused by solid state variable
speed control.
1.
Setscrew in downrod support is loose.
1.
Please replace the battery/batteries.
1.
The battery/batteries are going to run out.
2.
Setscrew in downrod/hanger ball assembly is
loose.
3.
Screws securing fan blade to motor assembly
are loose.
4.
Hanger bracket and/or ceiling outlet box is not
securely fastened.
Troubleshooting
For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.
WARNING
Trouble
Probable Cause
Suggested Remedy