F&U PAH-1029 Скачать руководство пользователя страница 3

I.

 

Notes 

Notes: 

 

The air conditioning is only suitable for indoor use, and not suitable for other applications. 

 

Follow local grid interconnection rules while installing the air conditioning and ensure 
that it is properly grounded. If you have any question on electrical installation, follow the 
instructions of the manufacturer, and if necessary, ask a professional electrician to install 
it.   

 

Place the machine in a flat and dry place and keep a distance of above 50cm between the 
machine and the surrounding objects or walls. 

 

After the air conditioning  is  installed, ensure that the power plug  is  intact and firmly 
plugged into the power outlet, and place the power cord orderly to prevent someone from 
being tripped or pulling out the plug. 

 

Do not put any object into the air inlet or outlet of the air conditioning. Keep the air inlet 
and outlet free from obstructions.   

 

When drainage pipes are installed, ensure that the drainage pipes are properly connected, 
and are not distorted or bended. 

 

While adjusting the upper and lower wind-guide  strips of the air outlet, pluck  it with 
hands gently to avoid damaging wind-guide strips. 

 

When moving the machine, make sure that it is in an upright position.   

 

The  machine  should  stay  away  from  gasoline,  flammable  gas,  stoves  and  other  heat 
sources.   

 

Don't disassemble, overhaul and modify the machine arbitrarily, otherwise it will cause a 
machine malfunction or even bring harm to persons and properties. To avoid danger, if a 
machine failure occurs, ask the manufacturer or professionals to repair it. 

 

Do not install and use the air conditioning in the bathroom or other humid environments.   

 

Do not pull the plug to turn off the machine. 

 

Do not place cups or other objects on the body to prevent water or other liquids from 
spilling into the air conditioning. 

 

Do not use insecticide sprays or other flammable substances near the air conditioning. 

 

Do not wipe or wash the air conditioning with chemical solvents such as gasoline and 
alcohol. When you need to clean the air conditioning, you must disconnect the power 
supply, and clean it with a half-wet soft cloth. If the machine is really dirty, scrub with a 
mild detergent.   

 

The appliance can be used by children aged from 8 years and above and persons with 

Содержание PAH-1029

Страница 1: ...INSTRUCTIONS MANUAL PAH 1029 PORTABLE AIR CONDITIONER Read and save these instructions for future reference ...

Страница 2: ...nd Adjustment IV Control Setting V Drainage Instructions VI Maintenance VII Troubleshooting VIII Appendix Thank you for choosing this luxurious and elegant portable air conditioning Please keep the manual for later review and read the manual carefully before use ...

Страница 3: ...nd lower wind guide strips of the air outlet pluck it with hands gently to avoid damaging wind guide strips When moving the machine make sure that it is in an upright position The machine should stay away from gasoline flammable gas stoves and other heat sources Don t disassemble overhaul and modify the machine arbitrarily otherwise it will cause a machine malfunction or even bring harm to persons...

Страница 4: ...treamlined machine With cooling heating dehumidification and fan function Continuous Water Drainage Function Control panel with LED display The machine is beautiful and elegant Product is equipped with high quality remote control for easy operation It adopts a user friendly remote control design Outdoor interface is set high to facility assembly and keep the smooth flow of the heat pipe Air filtra...

Страница 5: ...ng process ensure that the air conditioning is in the upright position and placed on a flat surface Do not install and use the air conditioning in the bathroom or other environments where humidity is present 1 1 Install the heat pipe assembly as shown in Fig 1 screw the heat pipe assembly exhaust fitting end into the exhaust port on the rear panel Exhaust Pipe Assembly Window Sealing Plate Assembl...

Страница 6: ...distance to bring both ends of the assembly into contact with the window frame and fix various components of the assembly 1 3 Install the body 1 Move the machine with installed heat pipe and fittings before the window making sure that the distance between the body and walls or other objects shall be least 50 cm as shown in Fig 4 2 Elongate the exhaust pipe and snap the flat end of the exhaust pipe...

Страница 7: ...l be 280 1 500mm and this length is based on the specifications of the air conditioning Do not use extension tubes or replace it with other different hoses otherwise it may cause malfunction Exhaust host must be not blocked otherwise it may cause overheating IV Control Panel Setting I Operating instructions LED Control Panel is as follows 1 Power Key 2 Mode Selection Key 3 Sleep Key 4 Down Key 5 U...

Страница 8: ...r press the up key or down key to select the required time 6 Wind Speed Selection Key In cooling and fan mode press the key to select high or low wind speed operation In heating mode press the key to select high medium and low wind speed operation Limited by anti cold conditions under certain conditions it may not run according to the set wind speed This key in dehumidifying mode is invalid and th...

Страница 9: ... press to increase temperature and timing set value 6 Fan press to select high low wind speed 7 Sleep Mode Press to turn on the sleep mode III A Variety of Protection Functions 3 1 Frost Protection Function In cooling dehumidifying or economic power saving mode if the temperature of the exhaust pipe is too low the machine will automatically enter into protection status if the temperature of the ex...

Страница 10: ...1 When the machine stops after the water is full turn off the machine power and unplug the power plug Notes Please move the machine carefully so as not to spill the water in the water pan at the bottom of the body 2 Place the water container below the side water outlet behind the body 3 Unscrew the drainage cover and unplug the water plug the water will automatically flow into the water container ...

Страница 11: ...age Optional only applicable to cooling dehumidifying mode as shown in figure 1 Unscrew the drainage cover and unplug the water plug 2 Set the drainage pipe into the water outlet 3 Connect the drainage pipe to the bucket ...

Страница 12: ...ing block of the EVA filter screen frame with hands Force down from the outside to remove the EVA filter screen frame Unscrew four screws fixing the EVA filter screen and the rear housing to remove the EVA filter screen as shown in the above figure 2 Put the EVA filter screen into warm water with neutral detergent about 40 104 and dry it in the shade after rinsing clean Unit Storage 1 Unscrew the ...

Страница 13: ...urn it on after connecting it to a socket with electricity The overflow indicator displays FL Discharge the water inside The ambient temperature is too low or too high Recommend to use the machine in at the temperature of 7 35 44 95 In cooling mode the room temperature is lower than the set temperature in heating mode the room temperature is higher than the set temperature Change the set temperatu...

Страница 14: ...control is not aligned with the direction of the remote control receiver Batteries are dead Replace batteries Displays E1 The pipe temperature sensor is abnormal Check the pipe temperature sensor and related circuitry Displays E2 The room temperature sensor is abnormal Check the room temperature sensor and related circuitry Note If problems not listed in the table occur or recommended solutions do...

Страница 15: ...parate collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY Herewith Amiridis Savvidis S A states that this product complies with the requirements of below directives EMC Directive 14 30 EU Low Voltage Directive 14 35 EU ErP Directive 09 125 EC CE Marking 93 68 EEC RoHS Directive 11 65 EU The detailed declara...