background image

- 6 -

power supply 

195÷253 V AC 

maximum load current (AC-1) 

5 A

contact 

separated 1×NO

contact status signalling 

red LED

receipt/programming signalling 

green LED

radio frequency 

868 MHz

power consumption 

0.8 W

working temperature 

-25÷50°C

terminal 

4×LY 1 mm², l= 10 cm

dimensions 

ø55, h= 21 mm

mounting 

for ø60 flush-mounted box

ingress protection 

IP20

Technical data

Содержание RS-407B

Страница 1: ...ter releasing the button Thanks to this even the shortest activation function is the full frame of data transmissions Data transmission from the remote control is indicated by flashing of red LED on t...

Страница 2: ...factors among others on the weather humidity terrain cha racteristics reflection placement of the receiver and transmit ter and all kinds of obstacles such as walls Perform tests before final assembl...

Страница 3: ...nformation During one open programming session the receiver can be attributed to many control remotes The non volatile memory can save up to 32 remotes There is a possibility of cooperation between ma...

Страница 4: ...blinks Receiving data from remote controls Learning red LED is flashing at the same time Long blink Memorization of button functions Short blink Button is already stored in the me mory 3 blinks Full m...

Страница 5: ...th the markings L phase wire to black conductor N neutral wire to blue conductor 3 The controlled receiver should be connected in series to the terminals X1 and X2 of the relay brown wires 4 Pair the...

Страница 6: ...1 NO contact status signalling red LED receipt programming signalling green LED radio frequency 868 MHz power consumption 0 8 W working temperature 25 50 C terminal 4 LY 1 mm l 10 cm dimensions 55 h 2...

Страница 7: ...ouncil of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repe aling Directive 1999 5 EC The CE Declaration of...

Страница 8: ......

Отзывы: