Active energy consumed  

AE+ 

[kWh]

The indicator has a pulse output. This allows you to connect a 

pulse meter-reading pulses generated by the counter. For proper 

operation of the indicator is not required to connect additional 

devices. 

The meter is marked with individual serial number allowing its 

unambiguous identification. The marking is laser engraved and 

cannot be removed).

Measured value

Pulse output

Meter number

Содержание LE-02d

Страница 1: ...agrożenie dla środowiska oraz zdrowia ludzi LE 02d Electric energy meter 3 phase MID Directive 2014 32 EU Certificate 0120 SGS0169 The LE 02d is a static electronic indicator calibrated electricity three phase alternating current in the system directly A special electronic system under the influence of current flow and applied voltage in each phase generates pulses in propor tion to the electricit...

Страница 2: ... reading pulses generated by the counter For proper operation of the indicator is not required to connect additional devices The meter is marked with individual serial number allowing its unambiguous identification The marking is laser engraved and cannot be removed Measured value Pulse output Meter number ...

Страница 3: ... 3 The meter has sealable input and output terminal covers to pre vent any attempts to bypass the meter Sealing ...

Страница 4: ... 4 Wiring diagram ...

Страница 5: ...remove the front shield meter terminals 4 Connect the voltage controlled phase following the indica tions to terminals 1 L1 3 L2 5 L3 5 N wire connect to terminal 7 Do not tighten the terminals without an inserted wire This may damage the clamping mechanism or the plastic cover of the terminal 6 Additional pulse receiver connected to terminals 20 21 The terminals are located under the top shell me...

Страница 6: ...tection class II housing PC material own power consumption 10 VA 2 W indication range 0 999999 99 kWh constant 800 pulses kWh current consumption signalling 3 red LED read out signalling red LED pulse output type open collector maximum voltage 27 V DC maximum current 27 mA pulse time 35 ms working temperature 25 55 C terminal 16 mm screw terminals dimensions 4 5 module 75 mm mounting on TH 35 rail...

Страница 7: ...clares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE and MID Declaration of Conformity along with the refe rences to the standards in relation to which conformity is decla red can be found www fif com pl on the product subpage Dimensions Warranty CE declaration ...

Страница 8: ...d overvoltage circuit breakers Before connecting the power supply make sure that all cables are connected correctly It is essential to observe the operating conditions of the meter supply voltage humidity temperature To avoid electric shock or damage to the meter turn off the power supply whenever the connection is changed Do not make any changes to the unit yourself Doing so can re sult in damage...

Отзывы: