F&F DRL-60-12 Скачать руководство пользователя страница 4

- 4 -

6. Attach the mounting frame to the box using screws or claws.

7. Connect the DRL-60-12 according to the selected wiring 

diagram.

When selecting the cable cross-section in low-voltage 

installations, it is necessary to take into account the vol-

tage drop on the cables related to the length and load 

of the cable.

8.  Use the dials to set the operating parameters of the detector: 

detection range, level of brightness below which switching will 

occur and switching time of the light.

9. Slide the detector into the box and press it onto the mounting 

frame. The magnets in the detector will prevent the detector 

from pulling out automatically.

The sensor is designed for the voltage supply of 12/24 

V DC. Connecting the 230 V mains voltage will destroy 

the device.

Description of control terminals

Содержание DRL-60-12

Страница 1: ...or This solution is perfect for switching on lighting circuits for exam ple on open stairs where it is important that the sensor detects presence only on the stairs and ignores everything that happens...

Страница 2: ...25D staircase li ghting timers Compact size can be mounted in a 60 mm box LED indicating the operating status of the sensor Thermal protection against exceeding the acceptable tempe rature inside the...

Страница 3: ...ncorrect operation of the distance and light intensity measurement system 3 Do not mount sensors opposite each other or mirrors as this can lead to unwanted sensor excitation 4 Prepare a hole for the...

Страница 4: ...load of the cable 8 Use the dials to set the operating parameters of the detector detection range level of brightness below which switching will occur and switching time of the light 9 Slide the dete...

Страница 5: ...ensor power supply 0 V OUT Lighting control output The DRL 60 12 is equipped with an open collector type output This means that the lighting to be controlled must be connected between the of the power...

Страница 6: ...ction area 3 TIME 0 10 min Lighting support time The light will switch on when presence is detected in the detection area the countdown time will start when there is no more obstacle in the detection...

Страница 7: ...control a load greater than 4 A the LED AMP 1P signal amplifiers mounting in an installation box 60 or LED AMP 1D mounting on a DIN rail should be used An example connection diagram can be found on th...

Страница 8: ...8 Connection of the AS 225 cascade controllers...

Страница 9: ...the detection area An obstacle in the detection area has been detected The light was not switched on because the brightness level was too high An obstacle in the detection area has been detected The l...

Страница 10: ...power supply 9 27 V DC maximum load current 4 A detection range adjustable 0 1 2 0 m brightness level adjustable 2 500 lx switch on time adjustable 0 10 min detection sensor ToF laser sensor wave len...

Страница 11: ...P declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaratio...