F&F DRL-60-12 Скачать руководство пользователя страница 2

- 2 -

»

Laser distance sensor of the ToF (Time of Flight) type;

»

The detection range can be smoothly adjusted in the range of 

0.1 to 2 m;

»

A brightness sensor that prevents the light from being swit-

ched on when the brightness level is high;

»

Adjustable time of keeping the light on;

»

Ability to directly control the 12/24 V lighting circuits (load 

capacity up to 4 A, which can be increased by connecting LED-

AMP amplifiers);

»

Soft start and soft shutdown feature available for controlled 

lighting circuits*;

»

Ability of integration with AS-225 and AS-225D staircase li-

ghting timers;

»

Compact size, can be mounted in a ø60 mm box;

»

LED indicating the operating status of the sensor;

»

Thermal protection against exceeding the acceptable tempe-

rature inside the housing.

*) Soft start and soft shutdown of the lighting works when the support time 

is set to a value greater than zero and when dimmable light sources are 

connected to the sensor.

1. The location of the mounting of the sensor should be selec-

ted in such a way that no fixed obstacles such as floor, wall, 

staircase step, etc. can be found in the detection cone of the 

sensor at the assumed operating distance. The diameter of the 

detection cone, depending on the set operating distance, can 

be read from the following figure:

Features

Mounting

Содержание DRL-60-12

Страница 1: ...or This solution is perfect for switching on lighting circuits for exam ple on open stairs where it is important that the sensor detects presence only on the stairs and ignores everything that happens...

Страница 2: ...25D staircase li ghting timers Compact size can be mounted in a 60 mm box LED indicating the operating status of the sensor Thermal protection against exceeding the acceptable tempe rature inside the...

Страница 3: ...ncorrect operation of the distance and light intensity measurement system 3 Do not mount sensors opposite each other or mirrors as this can lead to unwanted sensor excitation 4 Prepare a hole for the...

Страница 4: ...load of the cable 8 Use the dials to set the operating parameters of the detector detection range level of brightness below which switching will occur and switching time of the light 9 Slide the dete...

Страница 5: ...ensor power supply 0 V OUT Lighting control output The DRL 60 12 is equipped with an open collector type output This means that the lighting to be controlled must be connected between the of the power...

Страница 6: ...ction area 3 TIME 0 10 min Lighting support time The light will switch on when presence is detected in the detection area the countdown time will start when there is no more obstacle in the detection...

Страница 7: ...control a load greater than 4 A the LED AMP 1P signal amplifiers mounting in an installation box 60 or LED AMP 1D mounting on a DIN rail should be used An example connection diagram can be found on th...

Страница 8: ...8 Connection of the AS 225 cascade controllers...

Страница 9: ...the detection area An obstacle in the detection area has been detected The light was not switched on because the brightness level was too high An obstacle in the detection area has been detected The l...

Страница 10: ...power supply 9 27 V DC maximum load current 4 A detection range adjustable 0 1 2 0 m brightness level adjustable 2 500 lx switch on time adjustable 0 10 min detection sensor ToF laser sensor wave len...

Страница 11: ...P declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaratio...

Страница 12: ......