background image

- 1 -

AS-225D

12-channel 

cascade controller

The AS-225D controller is designed for cascade control of 

12÷24 V staircase lighting, which allows to achieve the effect of 

light following a person walking up or down the stairs.

»

Control of cascading multi-point lighting system;

»

The ability to set the number of controlled light points (from 

3 to 12);

»

The ability to connect controllers in series to increase the num-

ber of controlled circuits;

»

Additional control inputs:

̶

permanent light switching (for example during houseworks);

̶

light switching lock (for example brightness sensor signal);

»

Control of light using a variety of setters including bell buttons, 

motion sensors, optical barriers, pressure sensors, etc.

»

Adjustable 

"

soft start

"

 feature – soft brightening and dimming 

of lighting;

Purpose

Features

F&F Filipowski sp. j.

Konstantynowska 79/81, 95-200 Pabianice, POLAND

phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71

www.fif.com.pl; e-mail: [email protected]

Do not dispose of this device in the trash along with other waste! 

According to the Law on Waste, electro coming from households free of charge and can 

give any amount to up to that end point of collec� on, as well as to store the occasion of 

the purchase of new equipment (in accordance with the principle of old-for-new, regard-

less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the 

environment and human health.

Содержание AS-225D

Страница 1: ...trol of light using a variety of setters including bell buttons motion sensors optical barriers pressure sensors etc Adjustable soft start feature soft brightening and dimming of lighting Purpose Features F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Donotdisposeofthisdeviceinthetrashalongwithother...

Страница 2: ... brightness level when off so that the stairs are never completely dark Installation of the controller on a DIN rail Built in thermal protection The operating parameters of the AS 225D controller are set using the knobs on the front of the unit The operating status is indicated by LEDs Operator panel ...

Страница 3: ...rom 3 to 30 seconds Warning This is the minimum switch on duration of the output If the UP or DOWN input is trig gered for a long time it will increase the output switch on duration accordingly DELAY Delay between switching on subsequent outputs of the controller The setting range 0 100 re fers to the set time of switching on of the output So if for example the switch on duration of a single outpu...

Страница 4: ...cause the controller and the night light feature to work only at the actual low brightness level LED signalling U Controller power indication OUT Output circuit power indication OVER TEMP Signalling that the acceptable temperature inside the controller is exceeded Warning The AS 225D controller is equipped with thermal protection to prevent excessive overloading of the output circuits If the tempe...

Страница 5: ... brightness level limited to 1 2 the maximum value Fast flashing Alarm temperature exceeded output bright ness level limited to 1 8 the maximum value On Persistent exceeding of the alarm temperatu re controller outputs turned off If the thermal protection is tripped normal operation is restored automatically as soon as the temperature falls to a safe level ...

Страница 6: ... 6 Wiring diagram ...

Страница 7: ...ton starts the cascade moving from the bottom to the top The circuits will be switched on starting from OUT 1 OUT 2 OUT 3 and so on until the last controlled output is reached Each of the outputs will be switched on for the time TIME set by the knob on the con troller The delay between switching on subsequent outputs is set on the controller with the DELAY knob Warning If the DOWN button remains p...

Страница 8: ... The delay between switching on subsequ ent outputs is set on the controller with the DELAY knob Warning If the UP button remains pressed the lights remain on for the duration of the press The shutdown sequence of each output will begin when the UP button is released ON Control input Triggering the ON input causes simul taneous activation of all controlled output circuits of the controller The cir...

Страница 9: ... connec tion and the power of the light source Connect the wire of the lights to the OUT terminals and connect the wire directly to the of the power supply according to the installation diagram above The maximum current of a single lamp shall not exceed 4 A while the total current of all lamps switched on at the same time shall not exceed 24 A Warning Provide a power supply unit of sufficient capa...

Страница 10: ...ed with each other and with the terminals of the AS 225D controller Starting another cascade while the previous one is run ning will not interrupt the work of the first one but will start the next one in the set direction The exception here is the situation described in the next comment If during the cascade execution the last light is already switched on and at the same time an input DOWN or UP i...

Страница 11: ...uits exceeds 12 the system can be expanded by connecting several AS 225D controllers in series A sample wiring diagram is shown in the figure below Example of cascade control According to the above scheme any number of control lers can be combined ...

Страница 12: ...24 A maximum voltage 30 V DC input type potential free switch on duration 1 channel 3 30 s delay in switching on the next channel 0 switch on duration power consumption standby 1 W on 4 W terminal 2 5 mm screw terminals tightening torque 0 4 Nm working temperature 15 50 C dimensions 4 modules 52 5 mm mounting on TH 35 rail ingress protection IP20 Technical data ...

Страница 13: ...th us F F Filipowski sp j declares that the device is in conformity with the essential requirements of the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along with the references to the standards in relation to which conformity is declared can be found at www fif com pl on the product page Warranty CE declaration E210721 ...

Страница 14: ......