Lumina 16
Installer
40
Position lee side
Setting of the compass positions, which represent the lee side of the house. If the wind
comes from this direction (positions) under wind side, the ventilation control may be
influenced.
INSTALLER
VENTILATION
INLETS
tab page
Nat.
Description
Setting of the name of the function.
Temp. inputs
Setting for the addresses of the temperature inputs.
Output address
Setting of the analog output address.
Analog type
Setting indicating the analog control type
During mech.vent.
Setting if the air inlet is open or closed during this phase.
FOLLOW COMBI
: according to the percentage in the combi-table (normal setting).
CLOSED
: close (the curtain at the side of house where the fans are placed must be
closed during mechanical ventilation).
CLOSED UNTIL
: close until a certain combi step, from this step the inlet will follow
the combi-table.
During nat.vent
Setting indicating if the extra inlets have to be open or closed during natural ventilation.
CLOSED
: close (normal setting)
FOLLOW NAT.
: if this air inlet must follow the natural curtain (e.g. tunnel curtains
which also have to open during natural ventilation).
Pre-run time
Setting of the time in which the air inlets go to the required position, before the fans
activate.
Position wind side
Setting of the compass positions, which represent the wind side of the house. If the
wind comes from this direction (positions), the ventilation control may be influenced.
Position lee side
Setting of the compass positions, which represent the lee side of the house. If the wind
comes from this direction (positions) under wind side, the ventilation control may be
influenced.
Combi start/stop
Setting of values between which ventilation is natural.
Damping
Setting of the opening/closing speed of air inlets during natural ventilation.
Min.Wait time
Setting of the minimum wait time for transition. Within this time the controller cannot go
back to natural ventilation.