background image

IR.20-150

  

 

4

 

4.  Mounting 

 
Observe the following points when mounting the egg counting system: 
 
1. 

Mount the egg counter in an inclined position above the conveyor using 
the bracket supplied (see Fig. 1). See bracket mounting drawing. 

2. 

The  sensor  is  at  the  bottom  of  the  egg  counter.  Ensure  the  bracket 
does not cover the sensor. 

3. 

For  an  optimal  count  the  eggs  must  be  motionless  on  the  belt.  When 
stopped, the belt should not back wind.  

4. 

When  mounted  on  a  cross  conveyor,  the  egg  counter  should  be 
positioned  where  the  eggs  cannot  move  (sideways).  Moving  eggs 
could be registered more than once. 

5. 

Intense  light,  namely  sunlight  and  fluorescent  light,  can  influence 
accuracy.  Place  the  egg  counter  out  of  direct  (sun)  light,  or  shield  it 
from light. 

6. 

Mount the IR egg counter 2,5 cm above a large egg (no double-yolk).
 

 

 

0,85cm

 

2,5cm

 

β

 = 9°

 

β

 

 

 

Fig. 1: Mounting the egg counter above the cross conveyor (side view).  

Содержание IR.20-150

Страница 1: ...GB IR 20 150 MANUAL EGG COUNTING SYSTEM...

Страница 2: ...rranty must be commenced within one 1 year from the date of the breach Fancom is not bound by representations warranties or promises made by others beyond the terms of the Limited Warranty WARNING Ind...

Страница 3: ...20 IR 30 IR 40 IR 50 IR 150 Satisfies the conditions set out in 1 The Low Voltage Guideline Directive 2006 95 EC According EN 60335 01 2002 2 The EMC Guideline Directive 2004 108 EC Emission accordin...

Страница 4: ...IR 20 150 Table of contents About this manual 1 Introduction 1 2 Technical specifications 2 3 Safety instructions and warnings 3 4 Mounting 4 5 Electrical connection 5 6 Working 6 7 Maintenance 7...

Страница 5: ...y questions please do not hesitate to contact Fancom The subjects discussed in this manual are listed in the table of contents The following symbols are used in this manual Suggestions advice and note...

Страница 6: ...ecially developed for egg counting The eggs are placed on a conveyor belt and pass underneath the egg counter Infrared technology is used to count the eggs The advantage of this technique is that the...

Страница 7: ...s IP54 Dimensions l w h IR 20 230 50 31mm 9 00 1 96 1 22ins IR 30 330 50 31mm 12 90 1 96 1 22ins IR 40 430 50 31mm 16 90 1 96 1 22ins IR 50 530 50 31mm 20 80 1 96 1 22ins step 100mm 3 9ins IR 150 1530...

Страница 8: ...rrect installation and or a non or partially functioning installation 1 Read the safety instructions carefully before mounting and using the IR 20 150 2 After unpacking the IR 20 150 check for any pos...

Страница 9: ...unt the eggs must be motionless on the belt When stopped the belt should not back wind 4 When mounted on a cross conveyor the egg counter should be positioned where the eggs cannot move sideways Movin...

Страница 10: ...f a malfunction 5 Separate high low voltage cables by mounting them in separate cable channels 6 If metal cable channels are used ground them 7 Seal all gland nuts to prevent the entry of moisture Cau...

Страница 11: ...pulse per 10 eggs LED indication The IR 20 150 has several LEDs the IR 20 has 2 leds the IR 30 3 leds the IR 40 4 leds the IR 50 5 leds until IR 150 15 leds These leds indicate the egg counter status...

Страница 12: ...y clean the lens Clean a dirty lens with an antistatic cloth or compressed air preferably once a month If necessary a non aggressive glass cleaner can be used Caution When cleaning the poultry house e...

Отзывы: