background image

IR.20-150 

 

 

EC-declaration of compliance 

 
Manufacturer 

: Fancom B.V. 

Address 

: Industrieterrein 34 

City 

: Panningen (the Netherlands) 

 
 
Hereby declares that the: 

IR.20, IR.30, IR.40, IR.50 … IR.150 

 
 
Satisfies the conditions set out in: 

1.  The Low Voltage Guideline (Directive 2006/95/EC) 

According EN-60335-01:2002 

2.  The EMC-Guideline (Directive 2004/108/EC),  

Emission according NEN-EN 61000-6-3:2001 
Immunity according NEN-EN 61000-6-2:2001 

 
Panningen 

14-03-2012 
 

 

 

 

  
Chris van Erp 

  
Wout Hoolboom 
 

Manager Technology 

Project Manager  

 
  
 

Содержание IR.20-150

Страница 1: ...GB IR 20 150 MANUAL EGG COUNTING SYSTEM...

Страница 2: ...rranty must be commenced within one 1 year from the date of the breach Fancom is not bound by representations warranties or promises made by others beyond the terms of the Limited Warranty WARNING Ind...

Страница 3: ...20 IR 30 IR 40 IR 50 IR 150 Satisfies the conditions set out in 1 The Low Voltage Guideline Directive 2006 95 EC According EN 60335 01 2002 2 The EMC Guideline Directive 2004 108 EC Emission accordin...

Страница 4: ...IR 20 150 Table of contents About this manual 1 Introduction 1 2 Technical specifications 2 3 Safety instructions and warnings 3 4 Mounting 4 5 Electrical connection 5 6 Working 6 7 Maintenance 7...

Страница 5: ...y questions please do not hesitate to contact Fancom The subjects discussed in this manual are listed in the table of contents The following symbols are used in this manual Suggestions advice and note...

Страница 6: ...ecially developed for egg counting The eggs are placed on a conveyor belt and pass underneath the egg counter Infrared technology is used to count the eggs The advantage of this technique is that the...

Страница 7: ...s IP54 Dimensions l w h IR 20 230 50 31mm 9 00 1 96 1 22ins IR 30 330 50 31mm 12 90 1 96 1 22ins IR 40 430 50 31mm 16 90 1 96 1 22ins IR 50 530 50 31mm 20 80 1 96 1 22ins step 100mm 3 9ins IR 150 1530...

Страница 8: ...rrect installation and or a non or partially functioning installation 1 Read the safety instructions carefully before mounting and using the IR 20 150 2 After unpacking the IR 20 150 check for any pos...

Страница 9: ...unt the eggs must be motionless on the belt When stopped the belt should not back wind 4 When mounted on a cross conveyor the egg counter should be positioned where the eggs cannot move sideways Movin...

Страница 10: ...f a malfunction 5 Separate high low voltage cables by mounting them in separate cable channels 6 If metal cable channels are used ground them 7 Seal all gland nuts to prevent the entry of moisture Cau...

Страница 11: ...pulse per 10 eggs LED indication The IR 20 150 has several LEDs the IR 20 has 2 leds the IR 30 3 leds the IR 40 4 leds the IR 50 5 leds until IR 150 15 leds These leds indicate the egg counter status...

Страница 12: ...y clean the lens Clean a dirty lens with an antistatic cloth or compressed air preferably once a month If necessary a non aggressive glass cleaner can be used Caution When cleaning the poultry house e...

Отзывы: