Gnd
5
g
Settings
I/O address
Control type
I/O
adrr.
DIP 1 DIP 2 DIP 3 DIP 4 DIP 5
DIP 6 DIP 7
DIP 8 Control type
AN
On
On
On
On
On
On
On
On
CentralFlow (ATM with DSR)
1
Off
On
On
On
On
On
On
Off
AT(M) without DSR
2
On
Off
On
On
On
On
Off
On
NatuFlow / ProFlow direct
(analog output direct with
DSR-feedback)
3
Off
Off
On
On
On
4
On
On
Off
On
On
On
Off
Off
NatuFlow / ProFlow direct with
inverted manual operation
(analog output 10-0V direct
with DSR-feedback)
5
Off
On
Off
On
On
6
On
Off
Off
On
On
7
Off
Off
Off
On
On
8
On
On
On
Off
On
Off
On
On
Energy saving mechanical
9
Off
On
On
Off
On
Off
On
Off
Energy saving mech. & natural
10
On
Off
On
Off
On
Off
Off
On
Traditional mechanical
11
Off
Off
On
Off
On
Off
Off
Off
Mechanical several units
12
On
On
Off
Off
On
13
Off
On
Off
Off
On
Adjustment
14
On
Off
Off
Off
On
DIP 9* DIP
10*
15
Off
Off
Off
Off
On
On
On
No adjustment (working position)
16
On
On
On
On
Off
Off
On
Adjust control input
17
Off
On
On
On
Off
On
Off
Adjust 1% fan control output
18
On
Off
On
On
Off
Off
Off
Adjust max. revolutions
19
Off
Off
On
On
Off
* Change dipswitch settings 9 and 10 one at the time and
not simultaneously!
20
On
On
Off
On
Off
21
Off
On
Off
On
Off
22
On
Off
Off
On
Off
23
Off
Off
Off
On
Off
24
On
On
On
Off
Off
25
Off
On
On
Off
Off
26
On
Off
On
Off
Off
27
Off
Off
On
Off
Off
28
On
On
Off
Off
Off
29
Off
On
Off
Off
Off
30
On
Off
Off
Off
Off
31
Off
Off
Off
Off
Off