4
MOUNTING:
This product is intended for indoor installation, into locations already fitted with switched, pre-wired power outlets.
When selecting a mounting location, please consider the following:
•
Unit must be installed into a horizontal location, and is not suitable for wall mount or raked ceilings.
•
Prior to installation, inspect the ceiling cavity to check for hidden beams, structures and concealed electrical
cabling.
•
In applicable cases, the product should not be installed where the switch can be touched by someone within
a bath or shower.
•
Position fan in as central location as possible, to maximise ventilation to all areas.
•
Ensure that air is ventilated to an outside location via the use of a duct/grill assembly (not provided). Air
should not be ventilated into a sealed roof cavity.
•
Do not install the exhaust fan within 1m distance from a ceiling or wall mounted heat source.
•
There is a minimum installation depth of 220mm. Ensure there is at least 100mm clearance around and
above the exhaust fan once it is installed in the ceiling cavity.
INSTALLTION:
This fan comes in two sizes, and with or without light. Please ensure you are following the directions for the correct
installation.
1.
Cut off power supply and make preparations in the room to install a fan.
2.
Unpack the fan carefully and place it on a clean, flat surface.
3.
Remove the front fascia by gently pulling on it against the springs.
4.
Gently squeeze the springs, and remove them from their respective housing slots.
FOR LIGHT MODELS
: Before removing the fascia completely, reach in and unplug the light cable connector.