![Family inada HCP-27D Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/family/inada-hcp-27d/inada-hcp-27d_operating-manual_541777002.webp)
[Safety Precautions]
1
2
[Safety Precautions]
Remember to keep this Operating Manual in an easily accessible place.
Safety Precautions: Installation
l
Do not install the chair in an area of high hu-
midity such as a bathroom or sauna.
→
Could result in injury or electrical shock.
l
Do not use the chair outdoors.
Be sure that you have read these SAFETY PRECAUTIONS thoroughly before using your HCP-27D for the first time. The Operat-
ing Manual contains important information about how to use the chair safely and correctly, avoiding possible damage to property
or injury to persons using the chair and others. The symbols shown below are used throughout the Operating Manual to highlight
important safety instructions. Please adhere to all precautions. Descriptions of each chair component can be found on pages 5-8.
This action could result in death or
serious injury.
Warning
This action could result in personal
injury or damage to property.
Caution
l
Only install on a flat, level surface.
→
Chair could tip over accidentally if placed on an uneven surface.
Required Action
Prohibited
Types of Symbols and Description
Safety Precautions: While Using The Chair
Caution
Required Action
Required Action
Prohibited
Prohibited
Warning
Required Action
Caution
Safety Precautions: Before Using
Display Warnings
Caution
Safety Precautions: Before Using
Required Action
Warning
Prohibited
Prohibited
Safety Precautions
l
The following persons must not use this massage chair:
l
Don't use the chair with anything other than 220 V - 240 V power source.
→
May result in fire or electric shock.
l
Do not use with any type of transformer device.
→
Injury or electrical shock could result.
l
Do not use if power cord or outlet is damaged, or if power outlet is loose.
→
May result in electrical shock, short circuit or combustion.
→
Using the chair with holes or tears in the chair covering could result in injury or electric shock.
l
Be sure that the main POWER switch on the chair is OFF before plugging the power cord into the wall outlet.
→
Injury or electrical shock could result.
l
Be sure that the plugs on the power cord are inserted fully into connector and outlet.
→
May result in electrical shock, short circuit or combustion.
l
Before using the chair for the first time, turn on all the power switches in order as indicated in this
manual to check that the chair is operating properly.
l
Before using, raise the reclining seat back to its fully upright position. Then recline the seat back
slowly to the most comfortable position, remembering to start off with a lighter massage.
→
Starting with a deep massage can result in injury. Elderly people and persons with weak bones should be especially
careful when selecting massage intensity.
l
When sitting down in the chair, do so slowly, ensuring that the spinal rollers are in the correct posi-
tion at either side of the spine, so that the backbone lies comfortably between the rollers without
having to turn or twist the body.
l
Do not sit, stand or lean on the footrest unless you are sitting in the chair or getting up from the chair.
→
Personal injury or damage to the chair could occur if chair tips over.
l
If you have not used this chair for a period of time, read this Operating Manual again to ensure correct usage.
l
Do not use the chair in any way not prescribed by the Operating Manual. Do not use the chair to-
gether with any other therapeutic device or electric blanket.
→
May result in injury or have a negative effect on health.
l
Do not move the chair while someone is in it.
→
Accident or injury could result if the chair tips over.
l
Do not wrap the power cord or the remote control cord around the chair, or place the chair on top of either
cord. Do not scratch, tear, treat, unduly twist, stretch or bend the power cord or the remote control cord.
→
Cord may fray or tear, resulting in fire or electric shock.
l
Do not spill or drop water on the chair or the remote control.
→
May result in electrical shock, short circuit or combustion.
l
Children, persons who are unable to communicate, and persons who are physically challenged should
not be allowed to use the chair. Do not allow children or pets to play near the chair (especially behind
the reclining seat back or under the seat or footrest), climb on the chair or sit in the chair.
→
May result in accident or injury.
l
Do not use if chair covering is torn. Unplug the power cord from the wall outlet.
→
May result in injury, accident or electrical shock. Contact the store where you purchased the chair for repairs.
l
Do not place fingers or objects in between the footrest units, in between the footrest and the chair.
Be careful not to get hands caught when raising the footrest by hand.
l
Do not use the chair with wet body or wet hands.
→
Could result in injury or electrical shock.
l
Be sure that there is nobody (especially children), no pet or no object around this chair before reclining seat
back or lowering footrest. Be careful when reclining the seat back not to catch any parts of the body or ob-
jects behind the seat back.
Be careful not to catch feet or objects in between the footrest units when activating the foot slide function.
l
Do not use the chair unclothed.
l
Do not use the chair for purposes other than massage, or other than the ordinary uses of a chair.
→
May result in accident or injury.
l
Do not use the chair to massage the head, chest, stomach and joints (knees, elbows). Do not place
hands, feet or arms in between the rollers.
→
May result in nausea or injury. Place a soft towel behind your neck if you want to avoid intense stimulation of the area.
l
Do not place hands or feet into the roller tracks or into the space between the seat back and the
seat or into moving parts. Do not sit wearing hard object like hair accessories.
→
May result in personal injury.
l
Do not place anything other than legs and feet on the footrest.
→
May result in personal injury.
l
Do not operate the massage chair when there is no one in it.
→
May result in accident or injury.
¡
Persons who have been instructed by a doctor to avoid massage therapy. Ex. Thrombosis, severe aneurism, acute
varicosity, or dermatitis and/or skin infection including inflammation of the hypodermis.
¡
Person with suspected acute neck sprain (whiplash injury)
l
Space Requirements
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
l
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with
a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do
not modify the plug provided with the product if it will not fit the outlet, have a proper outlet installed by a
qualified electrician. This product is for use on a nominal 220-240V circuit and has a grounding plug that
looks like the plug illustrated in sketch in figure. Make sure that the product is connected to an outlet having
the same configuration as the plug. No adapter should be used with this product.
l
Persons with any of the following conditions must seek medical advice before using the chair.
¡
Serious heart problem
¡
Mental weakness caused by serious peripheral circulatory disorder due to diabetes and other diseases
¡
Osteoporosis, spinal fractures, acute pain and/or symptoms
¡
Persons with wounds on the parts being treated
¡
High fever (38˚C or higher) Ex. Strong acute inflammation illness caused by fatigue, chills, blood pressure fluctuation, or asthenia
¡
Persons in the early sages of pregnancy, or immediately after delivery of children
¡
Persons who have some electronic medical device(s) easy to be susceptible to electromagnetic interference Ex. pacemaker
¡
Abnormal or curved spine
¡
Persons planning to use chair to treat part of their body that is being or has been treated by a doctor
¡
Persons with malignant tumor(s)
¡
Persons needing bed rest
¡
Persons with acute gastro-intestinal complaints or ailments such as gastritis, enteritis, or hepatitis
¡
Persons under a doctor's care, or those experiencing unusual physical discomfort
¡
Deformed or misshapen joints due to rheumatism, gout, or other diseases
¡
Having such symptoms as qualm, stagger or tinnitus
¡
Inflammation due to sprain or torn muscles
l
Before each use, check for holes or tears in the chair covering (lift back pad to check seat back). Also,
check other part for no torn. Stop using the chair immediately if you find even the smallest tear. Un-
plug the chair and contact the store where you purchased the chair for assistance.
Prohibited
Do not
disassemble
Do not touch
Required action
Unplug the chair
Electrical
grounding
Warning or caution
Do not use in
or near water
such as in a bathroom
Prohibited
Electrical
grounding
GROUNDED OUTLET
GROUNDED OUTLET BOX
GROUNDING PIN