background image

5. Close battery pocket door, snapping it into place. 
6. Position smoke alarm to mounting plate and turn

tamper-resist

properly positioned in base. 

7. Push test button to test smoke alarm. 
    See TESTING THE SMOKE ALARM. 

TESTING THE SMOKE ALARM 

1. Test each smoke alarm to be sure it is installed correctly 

and operating properly.  

2. The push-to-test button accurately tests functions. Do not 

use an open 

fl

ame to test this smoke alarm. You may 

ignite and damage the smoke alarm or your home.  

3. Test smoke alarms weekly and upon returning from 

vacation or when no one has been in the household for 
several days.  

4. Stand at arm’s length from the smoke alarm when testing. 

clockwise to lock into place. To engage 

feature, insert pin into notch on edge of smoke alarm 
after alarm is 

THREE YEAR LIMITED WARRANTY

Master Distributors Pty Ltd warrants to the original 
consumer purchaser that each new smoke alarm is free 
from defects in material and workmanship under normal 
use and services for a period of three(3) years from the date
of purchase. Master Distributors Pty Ltd agrees to repair
or replace, at its option, any defective Smoke Alarm
provided it is returned personally or by prepaid delivery with
a copy of proof of purchase. Do not post.  
This warranty does not cover damage resulting from
accidents, misuse or abuse or lack of reasonable care
of the product. The purchaser's attention is drawn to rights
it may have under the Trade Practices Act 1974 and similar
state and territory legislation which cannot be excluded.
Subject to those non-excluded rights and provisions and
the above warranty, Master Distributors Pty Ltd, will not be
liable for any injury to persons or damage to property or
for any special direct or indirect or consequential loss or 
damage whatsoever and whether as a result of negligence
or fault on the part of Master Distributors Pty Ltd. or its
servants, agents, suppliers and contractors or otherwise
arising out of or resulting from, whether directly or
indirectly, the use, installation or maintenance of the
smoke alarm and any warranties or representations are
excluded unless given by  Master Distributors Pty Ltd in
writing. 
The 9 volt battery included with this Smoke Alarm is
excluded from the Master Distributors Pty Ltd, 3 year
Limited Warranty. If this Smoke Alarm is installed for 
use by others, please leave this document or a copy for
the end user.

TEST ALL SMOKE ALARMS WEEKLY

WITH THE FOLLOWING STEPS:

2. If smoke alarm does not sound, please retest the
     smoke alarm. 

DANGER:

If the alarm sounds, and smoke alarm is not
 being tested, the smoke alarm is sensing 

smoke. 

MAINTENANCE AND CLEANING 

In addition to weekly testing, this smoke alarm requires
yearly battery replacement and periodic cleaning to 
remove dust, dirt, and debris. 

BATTERY REPLACEMENT 

Replace battery at least once a year or immediately when
the low battery signal sounds once a minute. 

Batteries should be replaced regularly as necessary.   

WARNING: 

Do not use any other type of battery, other 
than as speci

fi

ed in this manual.   

Do not use rechargeable batteries. 

CAUTION

:

If the battery is incorrectly replaced, the smoke
 alarm will not operate and may cause damage.   

Please use high quality batteries to ensure long term
performance.
1. Turn smoke alarm counterclockwise to detach it from the
    mounting plate.   

2. Gently pull down smoke alarm.   

3. Remove battery from the compartment.   
4. Insert a new 9-volt battery to connector. NOTE THE 
     POLARITY OF CONNECTIONS.   

Ensure the metal tab is fully depressed when the battery
has been 

fi

tted. 

5. Reattach the smoke alarm to the mounting plate by
    turning smoke alarm clockwise until it snaps into place. 

6. Test the smoke alarm using “TEST” button.

See

 “TESTING THE SMOKE ALARM”

CHOOSING A REPLACEMENT BATTERY: 

The unit requires one standard 9V battery. The following
batteries are acceptable as replacements;
Golden Power #6F22, Megaton #6F22; New Leader #6F22;
Gold Peak #1604; Eveready #522, #1222 or equivalent
quality model available from electrical or hardware stores.  

CLEANING 

Clean the smoke alarm at least once a month to remove
dust, dirt, or debris. Using the soft  brush or wand

sure all the vents are free of

IMPORTANT: 

Do not attempt to remove the cover to 

void your warranty.   

THE SOUND OF THE ALARM HORN REQUIRES YOUR
IMMEDIATE ATTENTION AND ACTION. 

attachment from a vacuum cleaner, vacuum all sides and
cover of smoke alarm. Be 

debris. If necessary, use a damp cloth to clean smoke
alarm cover. 

clean inside the smoke alarm. This will 

PRACTICE FIRE SAFETY  

If the smoke alarm sounds its alarm horn, and you have
not pushed the test button, it is warning of a dangerous
situation. 

family escape plans, discuss them

1. Expose everyone to the sound of a smoke alarm and 
     explain what the sound means. 

2. Determine two exits from each room and an escape
     route to the outside from each exit. 
3. Teach all household members to touch the door and
     use an alternate exit if the door is hot. Instruct them 
     not to open the door if the door is hot. 
4. Teach household members to crawl along the 

fl

oor to

     stay below dangerous smoke, fumes and gases. 
5. Determine a safe meeting place for all members 
     outside the building. 

WHAT TO DO IN CASE OF FIRE  

1. Do not panic, stay calm.   
2. Leave the building as quickly as possible. Touch doors
    to feel if they are hot before opening them. Use an 

3. Meet at a pre-arranged meeting place outside the building. 

4. Call the 

fi

re department from outside the building. 

5. Do not go back inside a burning building. Wait for the 

fi

re

     department to arrive.     

These guidelines will assist you in the event of a 

fi

re. 

However, to reduce the chance that 

fi

res will start, 

practice 

fi

re safety rules and prevent hazardous situations. 

TROUBLESHOOTING 

WARNING:

 DO NOT disconnect battery to silence an 
 unwanted alarm. This will remove your 

protection. Ventilate the unit or open a 
window to remove smoke or dust. 

PROBLEM

SOLUTION

Smoke alarm does not sound
when tested. 

NOTE: Push test button for at
least 

fi

ve seconds while testing! 

1. Remove smoke alarm from mounting plate and check that

battery is properly attached to connector. 

2. Clean smoke alarm. 

Smoke alarm beeps about once a 
minute. 

Replace battery. See battery replacement in the maintenance and 
cleaning section. 

Smoke alarm sound unwanted 
alarms intermittently or when 
residents are cooking, taking 
showers, etc. 

1. Clean smoke alarm. See “CLEANING” in the maintenance and

cleaning section 

2. Move smoke alarm to a new location. See SMOKE ALARM 

PLACEMENT 

The alarm sounds di

erent than 

I’m used to. It starts and stops. 

The alarm is operating correctly. This alarm features the 
internationally recognised horn signal for evacuation. The alarm 
sound pattern is 3 short beeps followed by a 2 second pause and
then repeats. 

Your immediate response is necessary. To prepare for such
occurrences, develop 
 with all household members, and practice them regularly. 

alternate exit if necessary. Crawl along the 

fl

oor, and do

not stop to collect anything. 

AS3786

 Lic 21554

SAI Global

OPERATING YOUR SMOKE ALARM 

Once the smoke alarm has been installed A RED indicator
light (LED) should 

fl

ash approximately once a  minute to

If smoke is detected, the unit will emit a loud

fl

ashing quickly until the air is clear.   

The “HUSH” feature can mute the detector if it has
been inadvertently triggered by holding down the 
“TEST/HUSH” button for a few seconds. 
The smoke alarm will be muted 10 minutes and then 
reset into normal mode after this period.   
NOTE- If the smoke density increases during this time the

smoke alarm will be triggered into alarm again. 

indicate the battery is healthy and the unit is operating
properly.  
pulsating alarm and a RED indicator light (LED) will be 

NUISANCE ALARMS 

If there is a nuisance alarm simply press the test/hush
button on the alarm to silence the unit for 10 minutes. 
If, when the alarm goes o

, there is no sign of smoke,

heat or noise to indicate that there is a 

fi

re, you should get 

your family into a safe place, before you start investigating.  
Check the house carefully in case there is a small 

fi

re

smouldering somewhere. Check whether there is some 
source of smoke or fumes, for example cooking fumes
being drawn past the smoke alarm by an extractor. 
If there are frequent nuisance/false alarms it may be
necessary to re-locate the device away from the source 
of the fumes. If for some reason the alarm continues to
sound without smoke or heat being present (due to insect 
infestation or contamination build-up for example) the
unit can be silenced by disconnecting power and 
removing the unit for cleaning.  See “CLEANING”.

HUSH FEATURE 

This smoke alarm has a combined Test/Hush button to
help you control nuisance false alarms. 
1. To cancel a false

     smoke from a nearby 

fi

re will override the Hush on the

     smoke alarms). This condition allows unwanted alarms to
     be silenced for a period of approximately 10 minutes.  

The unit will 

fl

ash the red light every 10 seconds (instead

of the normal 40 seconds) to indicate the sensitivity is
reduced.  

On interconnected alarms, pressing the Test/Hush button
on the one sensing smoke (i.e. the one with the red light 

 

fl

ashing every second) will silence all alarms. Pressing the

 Hush Button on any other alarm will  not cancel the alarm. 

2. The unit will reset to normal sensitivity at the end of the
     silenced period. If additional silenced time is required,
     simply push the Test/Hush button again. 

alarm, press the Test/Hush button 

     located on the cover. The alarm will automatically switch
     to a reduced sensitivity condition (very large levels of 

Test & Hush

Button

1. Firmly push the TEST/HUSH button, and the smoke alarm
     will sound a loud beep.  The alarm will stop sounding after

 releasing the TEST/HUSH button. 

Отзывы: