Elevator Application Guidance
It is recommended that you thoroughly analyze the actual application requirements before designing
the electrical schematic and wiring of the elevator system.
The basic configuration of the elevator system consisting of MONT72 is shown in Figure 7-1.
Figure 7-1 Elevator system
7.1
Basic Commissioning Procedures
7.1.1
Set Basic Parameters
1
Correctly set F00.00 (Motor type) and F00.01 (Control mode) according to motor type.
2
Set Group F07 for the asyn. motor, set Group F10 for the syn. motor.
3
Set F00.02 (Rated speed of elevator) and F00.04 (Mechanical parameters of motor) according to the
elevator requirement and motor parameters.
4
Set encoder relevant parameters of Group F11 according to the encoder configured to motor.
5
Set digital I/O terminal parameters of Group F12 according to the actual wiring.
6
Set the parameter according to the actual running mode:
Terminal MS running mode:
•
Set MS parameters of Group F05 according to the actual requirement of elevator and the controller.
Set Acc. / Dec. curve parameters of Group F03 according to the elevator speed.
Terminal analogue running mode:
•
Set analogue curve parameters of Group F04 and analogue I/O terminal parameters of Group F13
according to the actual requirement of elevator and the controller.
•
The bigger Acc. / Dec. curve parameters of Group F03 are set, the quicker MONT72 catch the speed
command of elevator controller.
7.1.2
Motor Auto-tuning
Note:
The crane car is needed for the rotary auto-tuning but not for the stationary auto-tuning.
Asyn. motor parameter auto-tuning
1
Manually open the brake (rotary auto-tuning).
2
Set F07.06 as 1 (stationary auto-tuning) or 2 (rotary auto-tuning), then press
key to start parameter
auto-tuning. The motor will rotate at rotary auto-tuning, while it will not rotate at stationary auto-tuning.
MCCB
U
V
W
L1
L2
L3
R
S
T
M
MONT72
Car
Counter
weight
Input
terminal
Output
terminal
Elevator
Controller
Three-phase
power supply
380V 50/60Hz
Contactor
Weigh signal feedback
Speed feedback
PG
7
Содержание MONT72 Series
Страница 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Страница 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Страница 7: ......
Страница 9: ......
Страница 15: ......
Страница 43: ......
Страница 81: ......
Страница 99: ......