![Famco Hpmont HD3N-L Series Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/famco/hpmont-hd3n-l-series/hpmont-hd3n-l-series_manual_3297124077.webp)
Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameters
HD3N-L Series User Manual V1.0
- 67
-
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F05.13
FDT2
0.0 - 100.0% (F00.02)
90.0%
0.1%
○
F05.14
FDT1 delay level
0.0 - 100.0% (F00.02)
1.0%
0.1%
○
F05.15
FDT2 delay level
0.0 - 100.0% (F00.02)
1.0%
0.1%
○
F05.16
Speed within FAR range
0.0 - 20.0% (F00.02)
1.0%
0.1%
○
F05.17
Over-speed setting
80.0 - 120.0% (F00.02)
115.0%
0.1%
○
F05.18
Over-speed detection time
0.0 - 2.0s
0.2s
0.1s
○
F05.19
Detection value of speed
deviation
0.0 - 30.0% (F00.02)
0.0: Not detect
20.0%
0.1%
×
F05.20
Detection time of speed
deviation
0.0 - 2.0s
0.0: Not detect
1.0s
0.1s
×
F06: Optimize parameters (on pages 32)
F06.19
Brake premature close run
time
0.000 - 1.999s
0.000s
0.001s
×
F07: Motor parameters (on pages 33 - 35)
F07.00
Motor rated power
0.2 - 500.0kW
Depend on
HD3N-L
0.1kW
×
F07.01
Motor rated voltage
0V - controller rated voltage
Depend on
HD3N-L
1V
×
F07.02
Motor rated current
0.0 - 999.9A
0.1A
×
F07.03
Motor rated frequency
1.00 - 100.00Hz
50.00Hz
0.01Hz
×
F07.04
Motor rated RPM
1 - 24000rpm
1440rpm
1rpm
×
F07.05
Motor power facto
0.001 - 1.000
Depend on
HD3N-L
0.001
×
F07.06
Motor parameter auto-tuning
0: No action
1: Static auto-tuning
2: Rotational auto-tuning
0
1
×
F07.07
Motor stator resistance
0.000 - 65.535Ω
Depend on
HD3N-L
0.001Ω
×
F07.08
Motor rotor resistance
0.000 - 65.535Ω
0.001Ω
×
F07.09
Motor leakage inductance
0.0 - 6553.5mH
0.1mH
×
F07.10
Motor mutual inductance
0.0 - 6553.5mH
0.1mH
×
F07.11
Motor Idling excitation
current
0.0 - 999.9A
0.1A
×
F07.12
Motor core saturation
coefficient 1
0.00 - 0.50
0.50
0.01
×
F07.13
Motor core saturation
coefficient 2
0.00 - 0.75
0.75
0.01
×
F07.14
Motor core saturation
coefficient 3
0.00 - 1.20
1.20
0.01
×
F07.15
Motor torque boost
0.1 - 30.0%
0.1%
0.1%
○
F07.16
Motor manual torque boost
end-point
0.1 - 50.0% (F07.03)
2.0%
0.1%
○
F07.17
Motor slip compensation
gain
0.0 - 300.0%
100.0%
0.1%
○