11
the electronic control panel is correctly regulated (see setting the
cell temperature);
the device is neither in the defrosting phase or the post-defrosting
phase;
the condenser is not blocked with dust;
the device is not located near heat sources or its condensing unit is
not well-aired;
the stored foods or other objects do not inhibit the proper closing of
the door of the unit;
the device is not working in anomalous conditions (overloaded,
loaded with hot food, or loaded in a way that prevents proper air
circulation).
If the device leaks water (R, R S/S and RG models only) make sure
that:
the water elimination device is not damaged, that the discharge
has been well channeled, and that is not blocked;
the device has been positioned at a flat level.
It the device is making a lot of noise make sure that:
does not have loose screws or bolts;
the device has been correctly leveled and the feet are fixed in a
stable position.
If after all these controls the malfunctioning continues, it is advisable to
contact the technical assistance, indicating the model trade name, the
serial number (both can be found on the technical data plate) and the
alarm codes appearing on the display of the control panel.
9. DUTIES TO BE PERFORMED BY QUALIFIED ENGINEERS
Replacement of spare parts
Before commencing any maintenance work, disconnect the power plug
from the mains.
10. DEMOLITION
The scrapping of the cabinet has to be performed by a specialized
company, licensed by the local authorities, and observing local laws and
statutes.
The cabinet consists of:
structure in steel plate;
electrical components and cables;
electrical compressor;
plastic materials;
refrigerant fluid which must not be discharged into the atmosphere.
ALL THE RESPONSIBILITY FOR THE FAILURE TO RESPECT THE