9
ENGLISH
MAINTENANCE
Before cleaning or carrying out maintenance operations, disconnect the
equipment by removing the plug or switching off the main switch.
Do not use detergents containing abrasive, acidic or corrosive substances
or abrasive cloths.
Regular maintenance guarantees proper operation and performance over time.
Special attention is to be paid to the
metal anti-grease filters
: frequent cleaning of the
filters and their supports ensures that no flammable grease is accumulated.
CLEANING OF EXTERNAL SURFACES
You are advised to clean the external surfaces of the hood
at least once every 15 days
to
prevent oily substances and grease from sticking to them. To clean the brushed stainless
steel hood, the Manufacturer recommends using "Magic Steel" wipes.
Alternatively
and for all the other types of surfaces
, it can be cleaned using a damp cloth,
slightly moistened with mild, liquid detergent or denatured alcohol.
Finish off cleaning by rinsing well and drying with soft cloths.
Do not use too much water next to the push button control panel and
lighting devices in order to prevent humidity from reaching electronic
parts.
The glass panels can only be cleaned with specific, non-corrosive or non-abrasive deter-
gents using a soft cloth.
The Manufacturer declines all responsibility for failure to comply with these instructions.
CLEANING OF INTERNAL SURFACES
Do not clean electrical parts, or parts related to the motor inside the hood,
with liquids or solvents.
For the internal metal parts, see the previous paragraph.
LIGHTING
The range hood is equipped with high efficiency, low consumption LED light.
DISPOSAL AFTER END OF USEFUL LIFE
The crossed-out trash or refuse bin symbol on the appliance means that
the
product is WEEE
, i.e.
“
Waste electrical and electronic equipment'', accordingly
it
must not be disposed of with regular unsorted waste
(i.e. with ''mixed house-
hold waste''), but it must be disposed of separately so that it can undergo specif-
ic processing for its re-use, or a specific treatment, to remove and safely dispose of any
substances that may be harmful to the environment and remove the raw materials that can
be recycled. Proper disposal of these products contributes to saving valuable resources and
avoid potential negative effects on personal health and the environment, which may be
caused by inappropriate disposal of waste.
You are kindly asked to contact your local authorities for further information regarding the
designated waste collection points nearest to you. Penalties for improper disposal of such
waste can be applied in compliance with national regulations.
INFORMATION ON DISPOSAL IN EUROPEAN UNION COUNTRIES
The EU WEEE Directive was implemented differently in each country, accordingly, if you wish
to dispose of this appliance we suggest contacting your local authorities or dealer to find
out what the correct method of disposal is.
INFORMATION ON DISPOSAL IN NON-EUROPEAN UNION COUNTRIES
The crossed-out trash or refuse bin symbol is only valid in the European Union: if you wish
to dispose of this appliance in other countries, we suggest contacting your local authorities
or dealer to find out what the correct method of disposal is.
WARNING!
The Manufacturer reserves the right to make changes to the equipment at any time and
without prior notice. Printing, translation and reproduction, even partial, of this manual are
bound by the Manufacturer's authorisation.
Technical information, graphic representations and specifications in this manual are for in-
formation purposes and cannot be divulged.
This manual is written in Italian. The Manufacturer is not responsible for any transcription
or translation errors.
DUCTING & EXTRACTION LEVELS
(REMOTE MOTORS ONLY)
The Flexi ducting is designed to ensure optimum performance for your rangehood.
Please follow the installation instructions carefully.
Every FALMEC rangehood must be ducted to the external or in-roof motor unit by the use
of non-flammable ducting. The rangehood must not be ducted into a wall cavity or a ceiling
space where a build-up of grease can occur and become a potential fire risk.
Ensure the external outlet on the motor unit unit is not covered and the air flow is not
restricted in any way as this may result in reduced performance.
The duct must at all times have a cross sectional surface area equivalent to the hood outlet.
The hood outlet has a circular cross section of 200 mm in diameter or an approximate area
of 31,400 mm². Do not reduce the duct size at any time and avoid sharp bends. If the duct
run is longer than five (5) metres, it may be necessary to enlarge the duct size to ensure
optimum performance. The manufacturer does not guarantee performance when the duct
length is greater than five (5) metres.
THE RECOMMENDED DUCT LENGTH (INSTALLATION DISTANCE) IS 4 METERS.
THE MINIMUM INSTALLATION DISTANCE IS 3 METERS.
GENTLE BENDS IN THE DUCTING ARE RECOMMENDED AS IT ASSISTS IN MUFFLING
NOISE FROM THE EXTERNAL FAN UNIT.
SERVICING
The installation and fitting of the external or in-roof motor should be done in such a way
that will allow the unit to be removed if service is required. Additional costs incurred in the
removal, such as damage to walls and roofs, are not covered under warranty.
The external and in-roof motors unit should be checked regularly to ensure that nothing is
obstructing the air flow from the housing. We also recommend a routine inspection of the
remote units every 12 months to ensure optimum performance.
As part of ensuring the maximum life cycle of the remote motors it is advised to clean the
baffle filters on the rangehood every 4 weeks.
These filters are easily removable and dishwasher safe.
To Rangehood Unit
Gentle Bend
In Ducting
Содержание Treviso 90
Страница 1: ...INSTALLATION MANUAL falmecau com Treviso 90...
Страница 4: ...4 260 max 1079 263 60 519 max 500 898 490 133 2 200 TREVISO 90 FP5TV90S2...
Страница 15: ...15 NOTE NOTES...