background image

11

ENGLISH

 SAFETY INSTRUCTIONS

 AND WARNINGS

Installation operations are to be carried 

out by skilled and qualified installers in ac-

cordance with the instructions in this booklet and 

in compliance with the regulations in force.
DO NOT use the hood if the power supply cable 

or other components are damaged: 

disconnect 

the hood from the electrical power supply and con-

tact the Dealer or an authorised Servicing Dealer for 

repairs. 

Do not modify the electrical, mechanical or func-

tional structure of the equipment.
Do not personally try to carry out repairs or re-

placements. Interventions carried out by incom-

petent and unauthorised persons can cause seri-

ous damage to the unit or physical and personal 

harm, not covered by the Manufacturer's warran-

ty.

WARNINGS FOR THE INSTALLER

TECHNICAL SAFETY

Before installing the hood, check the integ-

rity and function of each part. Should 

anomalies be noted, do not proceed with installa-

tion and contact the Dealer.

Do NOT install the hood if an aesthetic (or cos-

metic) defect has been detected. Put it back into 

its original package and contact the dealer.
No claim can be made for aesthetic (or cosmetic) 

defects once it has been installed.

During installation, always use personal protective 

equipment (e.g.: Safety shoes) and adopt prudent 

and proper conduct.
The installation kit (screws and plugs) supplied with 

the hood is only to be used on masonry walls: in case 

of installation on walls of a different material, assess 

other installation options keeping in mind the type of 

wall surface and the weight of the hood (indicated on 

spec sheets at the beginning of this manual).
Keep in mind that installations with different types of 

fastening systems from those supplied, or which are 

not compliant, can cause electrical and mechanical 

seal danger.
Do not install the hood outdoors and do not expose 

it to atmospheric elements (rain, wind, etc.).

ELECTRICAL SAFETY

The electrical system to which the hood is 

to be connected must be in accordance 

with local standards and supplied with earthed 

connection in compliance with safety regulations 

in the country of use. It must also comply with lo-

cal standards regarding radio antistatic proper-

ties. 

Before installing the hood, check that the electrical 

mains power supply corresponds with what is report-

ed on the identification plate located inside the hood.

The socket used to connect the installed equipment 

to the electrical power supply must be within reach: 

otherwise, install a mains switch to disconnect the 

hood when required.

Any changes to the electrical system must be carried 

out by a qualified electrician. 

The maximum length of the flue fastening screws 

(supplied by the manufacturer) must be 1/2" (13 mm). 

Use of non-compliant screws with these instructions 

can lead to danger of an electrical nature.

Do not try to solve the problem yourself in the event 

of equipment malfunction, but contact the Dealer or 

an authorised Servicing Department for repairs.

When installing the hood, disconnect the 

equipment by removing the plug or switch-

ing off the main switch.

FUMES DISCHARGE SAFETY

Do no connect the equipment to discharge 

pipes of fumes produced from combustion 

(for example boilers, fireplaces, etc.).

Before installing the hood, ensure that all standards in 

force regarding discharge of air out of the room have 

been complied with.

USER WARNINGS

These warnings have been drawn up for 

your personal safety and those of others. 

You are therefore kindly asked to read the book-

let carefully in its entirety before using the or 

cleaning the equipment.
The Manufacturer declines all responsibility for 

any damage caused directly, or indirectly, to per-

sons, things and pets as a consequence of failing 

to comply with the safety warnings indicated in 

this booklet. It is imperative that this instructions 

booklet is kept together with the equipment for 

any future consultation.

Содержание Prisma FDPRI36W5SB

Страница 1: ...INSTRUCTIONS BOOKLET EN MODE D EMPLOI FR MANUAL DE INSTRUCCIONES ES LIBRETTO ISTRUZIONI IT INSTRUCTIONS BOOKLET Prisma Design FDPRI36W5SB FDPRI36W5SW ...

Страница 2: ...2 mm 45 5 8 1160 mm 4 1 8 105 mm 7 1 8 180 mm 13 3 4 440 mm 7 7 8 200 mm max 48 1220 mm 32 5 8 828 mm 16 7 8 429 mm max 15 380 mm ø5 16 8 mm ø1 8 6 mm 66lb 30 kg PRISMA 46 Cod FDPRI36W5SB FDPRI36W5SW 120VAC 60Hz 280W EN tool required FR outil requis ES herramienta requerida IT Attrezzi necessari ...

Страница 3: ...m the back of the hood FR Sortie alternative arrière le moteur dépasse de l arrière de la hotte de 3 8 10 mm ES Salida alternativa posterior el motor sobresale 3 8 10 mm en la parte posterior de la campana IT Uscita alternativa posteriore il motore sporge dal retro della cappa di 3 8 10 mm EN cable length 5 0ft 1 5m FR longueur de câble 5 0ft 1 5m ES longueur de câble 5 0ft 1 5m IT lunghezza cavo ...

Страница 4: ...nstallation avec sortie verticale Mesures pour l installation 1 Fixation de la hotte 2 ES Instalación con salida vertical Medidas para la instalación 1 Fijación de la campana 2 IT Installazione con uscita verticale Misure per l installazione 1 Fissaggio cappa 2 EN Mandatory safety screws FR Vis de sécurité obligatoires ES Tornillos de seguridad obligatorios IT Viti di sicurezza obbligatorie ...

Страница 5: ...n 3 and suction pipe assembly 4 FR Installation du clapet anti retour 3 et montage du tuyau d aspiration 4 ES Instalación de la válvula antirretorno 3 y montaje del tubo de aspiración 4 IT Installazione valvola di non ritorno 3 e montaggio tubo d aspirazione 4 ...

Страница 6: ...nnement du moteur 6 ES Instalación con salida posterior Medidas para la instalación 5 Reubicación del motor 6 IT Installazione con uscita posteriore Misure per l installazione 5 Riposizionamento motore 6 V7 x6 5 Connettore comandi Panel control connector 2 1 Cavo alimentazione Power cable 3 4 5 6 H 1 14 3 4 374 mm 20 7 8 530 mm 4 ø 5 16 8 mm V1 x2 S 14 3 4 374 mm 2 3 x2 ...

Страница 7: ...7 x4 T 1 Connettore comandi Panel control connector 5 Cavo alimentazione Power cable 6 7 V8 x2 4 T EN Motor repositioning 7 FR Repositionnement du moteur 7 ES Reubicación del motor 7 IT Riposizionamento motore 7 ...

Страница 8: ...nillos de seguridad obligatorios IT Viti di sicurezza obbligatorie EN Check valve installation 8 Hood fastening 9 FR Installation du clapet anti retour 8 Fixation de la hotte 9 ES Instalación de la válvula antirretorno 8 Fijación de la campana 9 IT Installazione valvola di non ritorno 8 Fissaggio cappa 9 ...

Страница 9: ...9 G H V3 x6 2 1 1 2 1 4 Ø1 8 6mm Ø1 8 6mm V4 x2 5 L H V5 x2 3 L 2 13 11 12 EN Optional chimney FR Cheminée en option ES Camino opcional IT Camino opzionale ...

Страница 10: ...15 FR Montage du filtre de série 14 15 ES Montaje del filtro de serie 14 15 IT Montaggio filtro di serie 14 15 EN Assembly of foptional filter 16 FR Montage du filtre en option 16 ES Montaje del filtro opcional 16 IT Montaggio filtro opzionale 16 KACL941 1 2 14 ...

Страница 11: ... not expose it to atmospheric elements rain wind etc ELECTRICAL SAFETY The electrical system to which the hood is to be connected must be in accordance with local standards and supplied with earthed connection in compliance with safety regulations in the country of use It must also comply with lo cal standards regarding radio antistatic proper ties Before installing the hood check that the electri...

Страница 12: ...os it in the equipment and compromise its operation Accessible parts of the hood can be hot when used at the same time as the cooking appliances Do not carry out any cleaning operations when parts of the hood are still hot There can be a risk of fire if cleaning is not carried out according to the instructions and products indicated in this booklet Disconnect the main switch when the equipment is ...

Страница 13: ...nnel The hood can be installed in various configurations The generic assembly steps apply to all installations for each case follow the specific steps provided for the required installation OPERATION WHEN TO TURN ON THE HOOD Switch on the hood at least one minute before starting to cook to direct fumes and vapours towards the suction surface After cooking leave the hood operating until complete ex...

Страница 14: ... the environment The active carbon filters must be replaced on average every 3 4 months under normal conditions of use See assembly instructions to replace the active carbon filters LIGHTING The range hood is equipped with high efficiency low consumption LED spot lights with an extremely long life span under normal use conditions Should the LED spotlight need to be replaced proceed as shown in the...

Страница 15: ...et de tenue mécanique Ne pas installer la hotte à l extérieur et ne pas l expo ser à des agents atmosphériques pluie vent etc SÉCURITÉ ÉLECTRIQUE Le circuit électrique auquel est reliée la hotte doit être aux normes et muni d un raccordement à la terre conformément aux normes de sécurité du pays d utilisation il doit en outre être conforme aux normes européennes sur l antiparasite radio Avant d in...

Страница 16: ...RDE POUR L UTILISATION ET LE NETTOYAGE Avant de procéder à toute opération de nettoyage ou d entretien désactiver l ap pareil en enlevant la fiche ou en agissant sur l in terrupteur général Ne pas utiliser la hotte avec les mains mouillées ou les pieds nus Contrôler toujours que toutes les parties électriques lumières aspirateur soient éteintes lorsque l appa reil n est pas utilisé Le poids maximu...

Страница 17: ...e de la hotte Il est nécessaire d isoler la tuyauterie si elle passe par des endroits non chauf fés Pour empêcher les retours d air de l extérieur un clapet de non retour est ins tallé en présence des moteurs avec 500CFM ou supérieurs HOTTE À RECIRCULATION INTÉRIEURE FILTRANTE Dans cette version l air passe à travers les filtres au charbon actif pour être purifié et est recyclé dans la pièce Contr...

Страница 18: ...ainsi renvoyé dans la pièce Les filtres au charbon actif doivent être remplacés en moyenne tous les 3 4 mois dans des conditions d utilisation normales Pour le remplacement des filtres au charbon actif voir les instructions de mon tage ÉCLAIRAGE La hotte est équipée d un éclairage par des spots LED à haute efficacité basse consommation et durée très élevée en conditions d utilisation normale S il ...

Страница 19: ...gentes atmosféricos lluvia viento etc SEGURIDAD ELÉCTRICA La instalación eléctrica a la cual se conecta la campana debe respetar las normas corres pondientes y tener obligatoriamente una conexión a tierra según las normas de seguridad del país de uso ademásdeberespetarlasnormativaseuropeas sobre la protección contra interferencias radio Antes de instalar la campana controle que la tensión de red c...

Страница 20: ...El aceite recalentado podría inflamarse No encienda llamas libres debajo de la campana No cocine con llamas libres debajo de la campana No use nunca la campana sin los filtros metálicos an tigrasa en este caso la grasa y la suciedad se deposi tarían en el equipo perjudicando su funcionamiento Las partes accesibles de la campana pueden estar ca lientes cuando se usan con equipos de cocción No reali...

Страница 21: ...os vapores y los olores con la función Temporizador es posible configurar el apagado automático de la campana después de 15 minutos de funcionamiento QUÉ VELOCIDAD SELECCIONAR I velocidad mantiene el aire limpio con bajos consumos de energía eléctrica II velocidad condiciones normales de uso III velocidad presencia de olores fuertes y de vapores IV velocidad eliminación rápida de olores y vapores ...

Страница 22: ...ue eliminar por separado siguiendo las operaciones correspondientes para su reciclaje o someterse a un tratamiento específico para eliminar de forma segura las sustancias dañinas para el medio ambiente y extraer las materias pri mas que se pueden reciclar La eliminación correcta de este producto contribu ye a salvar importantes recursos y evitar potenciales efectos negativos para la salud humana y...

Страница 23: ...rme di sicu rezza del Paese di utilizzo deve essere inoltre conforme alle normative Europee sull antidistur bo radio Prima di installare la cappa verificare che la tensione di rete corrisponda a quella riportata dalla targhetta posta all interno della cappa La presa usata per il collegamento elettrico deve es sere facilmente raggiungibile con l apparecchiatura installata in caso contrario preveder...

Страница 24: ...asso grasso e sporco in questo caso si depositereb bero nell apparecchio compromettendone il funzio namento Parti accessibili della cappa possono essere calde se utilizzate insieme con apparecchi di cottura Non effettuare operazioni di pulizia quando parti del la cappa sono ancora calde Se la pulizia non è condotta secondo le modalità e i prodotti indicati nel presente libretto è possibile un risc...

Страница 25: ...o In questa versione valvola di non ritorno non deve essere montata ri muoverla se presente sul raccordo di uscita aria del motore ISTRUZIONI DI MONTAGGIO parte riservata solo a personale qualificato La cappa ha la possibilità di essere installata in varie configurazio ni Le fasi di montaggio generiche valgono per tutte le installazioni seguire invece dove specificato le fasi corrispondenti all in...

Страница 26: ...ENTO A FINE VITA Il simbolo del cestino barrato riportato sull apparecchiatura in suo pos sesso indica che il prodotto è un RAEE cioè un Rifiuto derivante dal le Apparecchiature Elettriche ed Elettroniche e pertanto non deve essere gettato nella spazzatura indifferenziata cioè insieme ai rifiuti urbani misti ma deve essere gestito separatamente così da essere sottoposto ad ap posite operazioni per...

Страница 27: ...27 NOTES ...

Страница 28: ...Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com Codice Code Matricola Serial Number Code 110033058 Ed 01 2022 ...

Отзывы: