![FALMEC KRISTAL Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/falmec/kristal/kristal_instruction-booklet_3746138021.webp)
ENGLISH
21
Phase
C1
page 5
Only for version with external exhaust (suction):
if required by the selected height (
H1
), it is possible to install the hood using only the trellis (
T1
)
and the flue (
G
).
r
Attach the extension supporting elements (
SP
) to the trellis (
T1
) using the 8 self-threading screws (
V4
) through the pre-drilled holes (Fig.
1
)
r
Mark 4 drilling points on the ceiling (also identified on page
3
), drill (Fig.
2
) Put in 4 x ø 8mm expansion bolts and secure the extension sup-
porting elements (
SP
) to the ceiling by the relative screws (
V1
) (Fig.
3
).
With false ceilings, the extension supporting elements (SP) must always be bolted to the false ceiling: said false ceiling must be reinforced
or somehow fitted with a solution that can guarantee safely attaching the hood to it, taking into account the strength of the used materi-
als and the weight of the hood (reported on page.
2
).
The fixing kit (screws and plugs) supplied with the hood can only be used on masonry walls:
should it be necessary to install the
hood onto walls in a different material, assess other fixing systems keeping the wall resistance and weight of the hood in mind (indicated
on page
2
).
EXTERNAL EXHAUST HOOD VERSION (SUCTION)
r
If you wish, install the check valve (
M
)(
Phase
D
page 5
); if the connection is installed (
ERM
) take it down (Fig.
1
), install the check valve (
M
)
as illustrated in the figures (Fig.
2
-
3
-
4
-
5
) and put the previously removed connection back in (
ERM
) (Fig.
6
).
r
Find the best length for the flexible (recommended) or rigid pipe to discharge the fumes and connect it suitably to the connection (
Phase
E
page 5
).
HOOD VERSION WITH INTERNAL RECIRCULATION (FILTERING)
r
Ensure that the active carbon filters are assembled onto the hood, if not, install them as indicated in the instructions
Q
on page
9
.
r
If installed, remove the connection (
ERM
) and any check valve (
M
) installed on the hood's air outlet fitting (perform, in reverse order, the opera-
tion described in the instructions
D
page 5
).
INSTALLATION ON CEILING
Phases
F
-
G1
-
H
-
I
-
L
INSTALLATION ON CEILING WITH FALSE CEILING
Phases
F
-
G2
-
H
-
I
-
L
INSTALLATION ON CEILING WITHOUT EXTENSION (H) AND TRELLIS (T)
Phases
M
-
N
Phase
F
page 6
r
Insert the extension (
H
) into the flue (
G
) and secure them together with masking tape.
r
With external exhaust (suction) versions, it is possible to insert extension (
H
) with the slots facing downwards so that they are not visible when
the installation height allows it.
Phase
G1
page 6 (only for installations on ceiling WITHOUT false ceiling)
r
Raise the assembly (
H+G
) until it is touching the ceiling (Fig.
1
).
r
Attach the assembly (
H+G
) to the trellis (
T
) with 4 screws (
V3
) without tightening them all the way (Fig.
2
).
Phase
G2
page 6 (only for installations on ceiling WITH false ceiling)
Attach the extension supporting elements (
SP
) to the trellis (
T
) with 8 self-threading screws (
V4
) being sure to press it up against the false ceiling
Fig.
1
).
r
Raise the assembly (
H+G
) until it is touching the false ceiling (Fig.
2
).
r
Attach the assembly (
H+G
) to the extension supporting elements (
SP
) with 4 screws (
V3
) without tightening them all the way (Fig.
3
).
Phase
H
page 7
r
Raise the hood so that it is near the trellis that is already attached to the ceiling (Fig.
1
).
r
Centre the 4 metric screws, (
V5
) that are pre-screwed onto the trellis, (
T1
) (Fig.
2A
) on the holes on the hood; shift the hood sideways and tighten
the 4 metric screws definitively (
V5
) (Fig.
2B
).
Phase
I
page 7
r
Remove the masking tape that was temporarily holding the flue (
G
) and extension (
H
) (Fig.
1
)
r
Take out the 4 screws (
V3
) that attach the extension (
H
) to the trellis (
T
) (Fig.
2A
) or, with false ceilings, to the extension supporting elements (
SP
)
(Fig.
2B
) and slide the extension (
H
) downwards (Fig.
3
). Keep the removed (
V3
) screws.
r
By lowering the extension (
H
) it is possible to connect the pipe (
F
) to the external discharge pipe (with the suction version)(Fig.
4
).
r
Set up the electric connection only once the electric power supply has been cut off.
Phase
L
page 7
r
When the electrical connection is set up, as well as the discharge connection, raise the extension (
H
) (Fig.
1
) and re-attach it to the trellis (
T
) (Fig.
2A
) or, with false ceilings, to the extension supporting elements (
SP
) (Fig.
2B
) by the 4 screws (
V3
).
r
Attach the flue (
G
) to the hood by 2 self-threading screws (
V6
) (Fig.
3
).
INSTALLATION ON CEILING WITHOUT EXTENSION (H) AND TRELLIS (T)
Phase
M
page 8
r
Attach the flue (
G
) to the hood by 2 self-threading screws (
V6
) (Fig.
1
).
Phase
N
page 8
r
Raise the hood towards the trellis (Fig.
1
).
r
Set up the connection with the external discharge pipe and the electrical connection, performing the latter after disconnecting the electrical
power supply.
r
Centre the 4 metric screws, (
V5
) that are pre-screwed onto the trellis, (
T1
) (Fig.
2A
) on the holes on the hood; shift the hood sideways and tighten
the 4 metric screws definitively (
V5
) (Fig.
2B
).
Содержание KRISTAL
Страница 2: ...2 40 597 600 320 max 572 318 625 898 255 121 258 466 8 max 1212 8 mm KRISTAL ISOLA 30 KG 800 m3 h...
Страница 9: ...9 3 1 2 O 12V 1 2 3 1 2 2 Q P...
Страница 42: ...42 t t r r 2 r r r r r r r r 13 r t t r t t t Il l t r t r 8...
Страница 43: ...43 r r r r 1 5 r r r r r r r r t 42 A 4 65 25 6 EN60335 2 31 11 07 2002 TC61 7 12 1 15 10 11 r r r 70 C r r III...
Страница 46: ...46 15 30 3 4 47 15 30 3 Q 9 1 2 3 4 4 7 3 1 2 3 Q 9...
Страница 47: ...47 15 Magic Steel 1 55 C O 9 3 4 O 9 P 9 RAEE RAEE...