If the equipment is sold or transferred to another per-

son, make sure that the booklet is also supplied so 

that the new user can be made aware of the hood's 

operation and relative warnings. 
After the stainless steel hood has been installed, it 

will need to be cleaned to remove any residues re-

maining from the protective coating as well as any 

grease and oil stains which, if not removed, can cause 

irreversible damage to the hood surface. To properly 

clean the unit, the manufacturer recommends using 

the supplied moist wipes, which are also available 

sold separately. 
Insist on original spare parts.

State of California Proposition 65 Warning (US 

only) 

WARNING 

This product contains chemicals known to the Sta-

te of California to cause cancer and birth defects or 

other reproductive harm. 

For more information go to www.P65Warnings.ca.gov

INTENDED USE

The equipment is solely intended to be used to 

extract fumes generated from cooking food in 

non-professional domestic kitchens: any other 

use is improper. Improper use can cause damage 

to persons, things, pets and exempts the Manu-

facturer from any liability.

The equipment can be used by children over the age 

of 8 and by persons with reduced physical, sensory 

and mental abilities, or with no experience or knowl-

edge, as long as they do so under supervision or after 

having received relative instructions regarding safe 

use of the equipment and understanding of the dan-

gers connected to it.

Children are not to play with the equipment. Clean-

ing and maintenance by the user must not be carried 

out by children without supervision.

USE AND CLEANING WARNINGS

Before cleaning or carrying out mainte-

nance operations, disconnect the equip-

ment by removing the plug or switching off the 

main switch.

Do not use the hood with wet hands or bare feet.
Always check that all electrical parts (lights, extractor 

fan) are off when the equipment is not being used. 
The maximum overall weight of any objects placed 

or hung (if applicable) on the hood must not exceed 

3lb 5oz  (1.5 Kg).
Always supervise the cooking process during the use 

of deep-fryers: Overheated oil can catch fire.

Do not leave open, unattended flames under the 

hood.
Do not prepare food over an open flame under the 

hood.
Never use the hood without the metal anti-grease 

filters: in this case, grease and dirt will deposit in the 

equipment and compromise its operation.
Accessible parts of the hood can be hot when used at 

the same time as the cooking appliances.
Do not carry out any cleaning operations when parts 

of the hood are still hot.
There can be a risk of fire if cleaning is not carried out 

according to the instructions and products indicated 

in this booklet.
Disconnect the main switch when the equipment is 

not used for long periods of time.

If other appliances that use gas or other fu-

els are being used at the same time (boiler, 

stove, fireplaces, etc.), make sure the room where 

the fumes are discharged is well-ventilated, in 

compliance with the local regulations.

 INSTALLATION

 Intended only for qualified personnel

Before installing the hood, carefully read the section  'SAFETY 

INSTRUCTIONS AND WARNINGS'.

TECHNICAL FEATURES

The technical specifications are exhibited on the labels located inside the hood.

POSITIONING

The minimum distance between the highest part of the cooking equip-

ment and the lowest part of the hood is indicated in the installation in-

structions. 

Should the instructions for the gas cooker specify a greater distance, this must 
be taken into consideration.
Do not install the hood outdoors and do not expose it to outdoor environment 
(rain, wind, etc.).

ELECTRICAL CONNECTION

(Intended only for qualified personnel)

Disconnect the equipment from electrical mains power supply be-

fore carrying out any operations on the hood.

Ensure that the wires inside the hood are not disconnected or cut:

in the event of damage, contact your nearest Servicing Department.

Refer to qualified personnel for electrical connections.

Connection must be carried out in compliance with the provisions of law 

in force.

Before connecting the hood to the electrical mains power supply, check that:

• 

voltage supply corresponds with what is reported on the data plate located 
inside the hood;

• 

the electrical system is compliant and can withstand the load (see the techni-
cal specifications located inside the hood);

• 

the power supply plug and cable do not come into contact with temperatu-
res exceeding 158°F (70 °C);

• 

the power supply system is effectively and properly connected to earth in 
compliance with regulations in force;

• 

the socket used to connect the hood is within reach.

Содержание FFPLN36W5FS

Страница 1: ...CTIONS BOOKLET falmec com M A D E I N V I T TO R I O V E N E TO T V I TA LY EN INSTRUCTIONS BOOKLET FR MODE D EMPLOI ES MANUAL DE INSTRUCCIONES IT LIBRETTO ISTRUZIONI Plane Top wall FFPLN36W5FS FFPLN4...

Страница 2: ...m 2 3 8 60 mm 35 3 8 898 mm 5 7 8 150 mm min 23 5 8 600 mm 2 3 8 60 mm 13 3 8 340 mm 33 4 95mm 12 5 8 322 mm 1 27 mm 5 7 8 1 5 0 m m 10 3 8 265 mm 500 cfm 41 lb 19 kg Plane Top 36 Cod FFPLN36W5FS 120V...

Страница 3: ...m 2 3 8 60 mm 47 1 8 1198 mm 5 7 8 150 mm min 23 5 8 600 mm 2 3 8 60 mm 13 3 8 340 mm 33 4 95mm 12 5 8 322 mm 1 27 mm 5 7 8 1 5 0 m m 10 3 8 265 mm 500 cfm 55 lb 25 kg Plane Top 48 Cod FFPLN48W5FS 120...

Страница 4: ...omienda instalar la campana en este rango para optimizar el rendimiento Se recomienda no exceder 35 890mm para la dimensi n A ya que las campanas montadas por encima de sta pueden ser dif ciles de alc...

Страница 5: ...ntage du tuyau d aspiration 3 ES Fijaci n de la campana 1 instalaci n de la v lvula antirretorno 2 y montaje del tubo de aspiraci n 3 IT Fissaggio cappa 1 installazione valvola di non ritorno 2 e mont...

Страница 6: ...6 G H 1 V3 x6 2 4 L H 1 4 V4 x2 5 L H V5 x2 3 L 2 1 4 6 mm 1 4 6 mm 1 4 6 mm 5 EN Flue assembly FR Montage de la chemin e ES Montaje de la chimenea IT Montaggio camino...

Страница 7: ...7 7 EN Assembly of optional filter FR Montage du filtre en option ES Montaje del filtro opcional IT Montaggio filtro opzionale 1 2 3 4 5 6 3 2 1 7 1 2 2 8 MAGNET...

Страница 8: ...ose it to atmospheric elements rain wind etc ELECTRICAL SAFETY The electrical system to which the hood is to be connected must be in accordance with local standards and supplied with earthed connectio...

Страница 9: ...food over an open flame under the hood Never use the hood without the metal anti grease filters in this case grease and dirt will deposit in the equipment and compromise its operation Accessible part...

Страница 10: ...off function which will allow the hood to turn off automatically after 15 minutes of operation WHICH SPEED IS TO BE SELECTED 1st speed maintains the circulation of clean air with low electricity consu...

Страница 11: ...al and electronic equip ment accordingly it must not be disposed of with regular unsort ed waste i e with mixed household waste but it must be disposed of sepa rately so that it can undergo specific p...

Страница 12: ...ieur et ne pas l expo ser des agents atmosph riques pluie vent etc S CURIT LECTRIQUE Le circuit lectrique auquel est reli e la hotte doit tre aux normes et muni d un raccordement la terre conform ment...

Страница 13: ...c der toute op ration de nettoyage ou d entretien d sactiver l ap pareil en enlevant la fiche ou en agissant sur l in terrupteur g n ral Ne pas utiliser la hotte avec les mains mouill es ou les pieds...

Страница 14: ...cher les retours d air de l ext rieur un clapet de non retour est install en pr sence des moteurs avec 500 CFM ou sup rieurs HOTTE RECIRCULATION INT RIEURE FILTRANTE Dans cette version l air passe tr...

Страница 15: ...erse L air pur est ainsi renvoy dans la pi ce Les filtres au charbon actif doivent tre remplac s en moyenne tous les 3 4 mois dans des conditions d utilisation normales Pour le remplacement des filtre...

Страница 16: ...tmosf ricos lluvia viento etc SEGURIDAD EL CTRICA La instalaci n el ctrica a la cual se conecta la campana debe respetar las normas co rrespondientes y tener obligatoriamente una co nexi n a tierra se...

Страница 17: ...dos o colgados cuando est previsto en la campana no debe superar los 1 5 kg Controle las freidoras mientras las est usando El aceite recalentado podr a inflamarse No encienda llamas libres debajo de l...

Страница 18: ...a campana puede instalarse en diferentes configuraciones Las fases de montaje generales valen para todas las instalaciones mientras que para la instalaci n espec fica deben seguirse las indi caciones...

Страница 19: ...umo y una vida til prolongada en condiciones de uso normales Si es necesario sustituir la bombilla siga los pasos ilustrados en la figura 12V 3 1 2 ELIMINACI N AL FINAL DE LA VIDA TIL El s mbolo del c...

Страница 20: ...ropee sull antidi sturbo radio Prima di installare la cappa verificare che la tensione di rete corrisponda a quella riportata dalla targhetta posta all interno della cappa La presa usata per il colleg...

Страница 21: ...mettendone il funzio namento Parti accessibili della cappa possono essere calde se utilizzate insieme con apparecchi di cottura Non effettuare operazioni di pulizia quando parti del la cappa sono anco...

Страница 22: ...fino a completa aspirazione di tutti i vapori e odori con la funzione Timer possibile impostare l autospegni mento della cappa dopo 15 minuti di funzionamento QUALE VELOCIT SCEGLIERE I velocit mantie...

Страница 23: ...che possono essere riciclate Lo smaltimento corret to di questo prodotto contribuir a salvare preziose risorse ed evitare potenziali effetti negativi per la salute umana e per l ambiente che potrebbe...

Страница 24: ...Code 110033056 Ed 01 2020 Codice Code Matricola Serial Number Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com...