9.1.6.
Prohibited use
•
Only one user working at height, but without the support of a second person able to provide
assistance if needed.
•
More than four persons attached to the lifeline simultaneously.
•
the fall indicator is no longer visible, it has been pulled into the cylinder.
•
An obstacle under the walk way which reduces the clearance specified on the manufacturer’s
label
•
Deposits of ice on the cable and the anchors.
•
Temperatures lower than -30 °C
•
It is strictly prohibited to use the lifeline outside the limits specified in this document or outside
any other situation for which it is designed.
•
The length of the lanyard absorber is limited to 2 meters, except where there is a written
statement to the contrary from the manufacturer for a specific project.
•
It is forbidden to use any another karabiner to attach the lanyard to the glider that provided by
Fallprotec. The function of safety of the glider could be affected if the karabiner used is not
the karabiner supplied by FALLPROTEC.
9.1.7.
Instructions for storage and
maintenance
•
The glider must be stored in a place away from moisture.
•
The SecuRope lifeline must be inspected by a qualified person at least once a year, as well as
after every fall.
•
The safety of the users depends on the maintenance of the effectiveness and the resistance
of the equipment.
•
Reconditioning of the line after a fall requires a re-tensioning of the cable using FALLPROTEC
tools, as well as the repositioning of the guide cables on their support brackets. This work
must be carried out by a qualified person who has received an adequate training by
FALLPROTEC, and is in the possession of the Installer manual.
•
The lubrication of the cable is recommended once a year in order to facilitate the movement
of the glider. This recommendation is applicable only in an environment or installation where
the lifeline can accept oil lubrication.
•
Any modification of or addition to equipment can only be carried out after the prior written
agreement of FALLPROTEC.
•
If the equipment may be in contact with chemical, please contact Fallprotec and tell us the
exact name of the chemical concerned.
•
The correct tightening of bolts and nuts should be checked.
•
Check that the turnbuckle LDV038 is not released, tighten and lock it with Loctite