![Faller 161651 Скачать руководство пользователя страница 68](http://html.mh-extra.com/html/faller/161651/161651_instruction-manual_540502068.webp)
68
Traffic-Control
EN
Program 11
Fig. 16: DIP configuration Program 11
This program is used to distribute different vehicles depending on their actual
speed. That speed may vary depending on the capacity of the rechargeable
battery. The speed is measured between E1 and E3 (sensors built into the
roadway). Depending on the result of the measurement slow vehicles will
be steered to parking places via branch-off junctions and thus singled out
of the moving traffic. The other inputs will allow to clear the parking bays
again, at the modeller’s request. E5 to E8 will additionally switch on outputs
A5 to A8 for a given period of time.
Possible use
Timing
Distribution on traffic lanes depending
on vehicle speed/capacity of battery
Sensor/But-
ton at input
E1, E3
E2
E4
activates
AB 1
AB 2
P/FR 1
P/FR 2
at output
A1
A3
A2
A4
for the
period of
Poti 1
2 s
3 s
2 s
2 s
Possible use
X 1
X 2
X 3
X 4
Sensor at
input
E5
E6
E7
E8
activates
K
K
K
K
at output
A5
A6
A7
A8
for the
period of
Poti 2
1 s
15 s
20 s
Table 16: Program 11
X
Set the DIP as required, see Fig. 16.
X
Connect the components, see Table 16.
X
If necessary, set the desired period using the potentiometers.
Содержание 161651
Страница 1: ...161651 161654 Traffic Control Traffic Light Control Bedienungsanleitung Instruction Manual DE EN ...
Страница 82: ...82 Notizen Notes EN 11 Notizen Notes DE ...
Страница 108: ...108 Notizen Notes EN DE 12 Notizen Notes ...
Страница 109: ...109 Notizen Notes EN DE 13 Notizen Notes ...
Страница 110: ...110 Notizen Notes EN 14 Notizen Notes DE ...
Страница 111: ...111 Notizen Notes EN 15 Notizen Notes DE ...