SG Series

TM

UPS PLUS

®

1kVA to 3kVA

22

 

Model Number  

SG1KRM -1TU 

SG1KRM -2TU 

SG2KRM -1TU 

SG2KRM-2TU 

SG3KRM-1TU 

SG3KRM-2TU 

Nominal VA  

1000 

2000 

3000 

        

 

Electrical Input

 

Nominal AC Voltage 

120V 

230V 

120V 

230V 

120V 

230V 

AC Voltage Range  

87-140V 

170-275V 

87-140V 

170-275V 

87-140V 

170-275V 

Current-Amps   

6.9 

3.6 

14.2 

7.5 

21.4 

11.2 

Frequency

 

50/60 Hz  ± 5% (Auto–Tracking)

 

Power Factor Correction

 

> 0.95

 

Efficiency  (Typical)

 

> 89% 

> 86% 

 

Electrical Output  

Watts 

700 

700 

1400 

1400 

2100 

2100 

AC Voltage    
(Switchable ) 

100V 
110V 
115V 
120V 

200V 
220V 
230V 
240V 

100V 
110V 
115V 
120V 

200V 
220V 
230V 
240V 

100V 
110V 
115V 
120V 

200V 
220V 
230V 
240V 

Frequency

 

50/60 Hz (Auto Tracking )

 

Frequency Stability

 

± 0.3% (Battery Mode)

 

Voltage Regulation

 

±

 2%

 

Step Load Change

 

± 

7% for 100% load variation

 

Harmonic Dis tortion

 

< 3% Linear Load, < 5% Non -Linear Load

 

Overload

 

105% load for 50 Seconds

 

Crest Ratio

 

3:1

 

 

Battery 

DC Voltage  

48V 

72V 

96V 

Type

 

12V, 7AH Sealed  Lead Acid  Maintenance -Free

 

Back Up Time         @ Full Load  

                               @ 1/2 Load  

6 Minutes  

19 Minutes

 

7 Minutes  

20 Minutes

 

5.5 Minutes  

15 Minutes

 

Recharge Time

 

8 Hours to 90%

 

Battery times are approximate.  

 

Transfer Time  

Line Fails/Recovers  

Zero 

UPS to Bypass or Reverse  

< 4ms 

After Overload  

Auto Transfer to UPS  

 

Electrical Connecti ons 

Input 

6’ Cord with  

5-15P 

6’ Cord with  

Schuko or  

6-15P 

6’ Cord with  

L5-20P 

6’ Cord with  

Schuko or   

6-15P 

6’ Cord with  

L5 -30P 

6’ Cord with  

Schuko or  

 L6-20P 

Output 

(4) 5-15R 

(4) IEC320  

(4) 5-15R 

(4) IEC 320  

(4) 5-15R 

(4) IEC 320 

Contact the factory fo r other input/output options. . 

 

Environmental  

Operating Temperature  

0º C - 40º C (32º F to 104º F)  

Humidity  

10% to 95% Non  – Condensing  

Altitude  

7,000 Feet  

Cooling 

Low Velocity Forced Air Fans  

Audible Noise @ 1  Meter 

< 55dBA  

 

Controls and Indicators  

LED 

Line, Inverter, Battery Reserve, Load, Bypass, Alarm, Crest, Battery

 & Load Capacity Level  

Audible Alarms  

DC Mode, Low Battery, Over/Under Voltage, Over/Under Frequency,  High Temp. , Over Load, Fault Alarm  

Communications  

RS-232 Serial Port    (Bundled  UPSilon 2000 Software)  

 

Mechanical  

UPS Module  Dimensions  
Battery Pack Dimensions  

 H x W x  D                 Inches (mm)

 

3.51 x 16.8 x 17.7   (89 x 426.7 x 449.5)  

Internal to UPS Module  

3.51 x 16.8 x 17.7    (89 x 426.7 x 449.5)  

3.51 x 16.8 x 17.7   (89 x 4 26.7 x 449.5)   External to UPS Module  

2kVA & 3kVA are (2) cabinet configuration, Hot Swappable  Batteries  

UPS Module Weight       lb. (kg)  

Battery Pack Weight      lb. (kg)

 

39  (18) 

Internal 

29   (13) 

53  (24) 

29   (13) 
64   (29) 

Agency Listing  

UL 1778, CU L, 

FCC Class A  

CE

 available with 

Schuko plug only  

UL 1778, CUL,  

FCC Class A  

CE 

available 

with Schuko 

plug only

 

UL 1778, CUL,  

FCC Class A  

CE 

available 

with Schuko 

plug only

 

www.falconups.com - email: [email protected]

©

2003 Falcon

®

Electric, Inc.  All rights reserved. Falcon

®

and the Falcon Electric logo are registered trademarks of Falcon Electric, Inc.

All other brand names and trademarks are the property of their respective owners.
The information and specifications stated in this document are subject to change without notice. 

MD44010-1F      08-05-03

 

Available Options    

Option A  

60 Hz to 50 Hz Frequency Conversion

 

Option B  

50 Hz to 60 Hz Frequency Conversion  

Option C 

SNMP/HTTP Network Card (Internal)  

Option D 

Standard Contact Closure Interface Card  

External Battery Packs  

Extended Run Time Battery  Packs (minutes to hours)  

Slide Rails  

Heavy Duty Roller Bearing Slide Rails for side mounting  

Falcon Electric, Inc. -  5116 Azusa Canyon Rd. -  Irwindale, CA91706 -  800.842.6940 Fax 626.962.7720

All manuals and user guides at all-guides.com

Содержание UPS Plus SG Series

Страница 1: ...reserved All other brand names and trademarks are the property of their respective owners The information stated in this document is subject to change without notice 2007 03 20 Falcon Falcon Electric...

Страница 2: ...ion Description 10 Audible Alarms 12 Category One Alarms 12 Category Two Alarms 12 Chapter 4 Front Rear Panel Details 13 Front Panel Overview 13 SG1KRM 1TU Rear Panel Overview 13 SG1KRM 2TU Rear Panel...

Страница 3: ...erior Brownout Surge and Transient Protection Internal System Bypass Eliminates Generator Frequency Voltage Drift Microprocessor Control RS 232 Communications UPSILON Monitoring Shutdown Software Opti...

Страница 4: ...wledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing the UPS batteries use the same number and type of batteries Allow at least 24 hours...

Страница 5: ...Series UPS incorporates advanced microprocessor technology This technology makes possible a high level of internal UPS control and management With the supplied UPSILON software all SG Series UPS mode...

Страница 6: ...time of order verify for proper configuration 3 RACKMOUNT UPS MOUNTING INSTRUCTIONS IMPORTANT a NEVER MOUNT THE UPS OR ANY ASSOCIATED BATTERY BANKS USING ONLY THE FRONT PANEL MOUNTING EARS AS DAMAGE...

Страница 7: ...voltage This will assure a close matching voltage in the event the UPS is placed on bypass b Dip switch 3 enables or disables the Green Mode function The UPS is shipped from the factory with the switc...

Страница 8: ...battery fuse 8 If additional extended battery modules are to be installed perform the following a Perform the preperation outlined in preceding paragraphs 3a 3b abd 3c b Connect the supplied battery i...

Страница 9: ...ollowed by the bypass LED and after several seconds the inverter LED 13 Turn on the connected equipment and verify the UPS does not go into overload by observing the front panel load indicator LEDs 14...

Страница 10: ...for each module All 1kVA UPS models will only require one slide kit Slide Installation Instructions NOTE Only use the referenced lenght screws when mouning the slides to the sides of the UPS and batt...

Страница 11: ...25 Min 300 Min RUN TIME 500W 24 Min 55 Min 95 Min 135 Min 180 Min RUN TIME 700W 17 Min 40 Min 70 Min 100 Min 140 Min RUN TIME 1000W 11 Min 25 Min 42 Min 60 Min 80 Min RUN TIME 1400W 7 Min 16 Min 26 Mi...

Страница 12: ...the battery level is above the low battery warning Level The first LED is lit when the battery level is above the battery cutoff voltage 3 LINE SITE WIRING FAULT INDICATOR LED For models configured fo...

Страница 13: ...s the different modes of operation for this button a Depressing this button when the UPS is off and the utility voltage is not present or with the UPS input circuit breaker in the off position will ca...

Страница 14: ...rating range SG UPS OUTPUT VOLTAGE IS OUT OF PROPER RANGE b Four short beeps indicate the SG UPS output frequency is out of proper operating range The UPS must be repaired SG UPS OUTPUT FREQUENCY IS O...

Страница 15: ...Fan RS 232 Port Output Receptacles 4 IEC320 Power Cord Inlet 200 240Vac only Output Voltage Select Switch Battery Fuse 30A Extended Battery Connector Primary Battery Inside UPS shown with cover plate...

Страница 16: ...acles Primary Battery Connector shown with cover plate removed Cooling Fans RS 232 Port Output Receptacles 4 IEC320 Power Cord Inlet 200 240Vac only Output Voltage Select Switch Output Fuse Primary Ba...

Страница 17: ...e propriatary pin out of the RS 232 port There are communications options that WILL DISABLE the RS 232 port and render it inoperable The options are as follows a Internal SNMP HTTP agent option instal...

Страница 18: ...ommon only PIN JUMPER ASSIGNMENT FOR THE FALCON UA88374 RELAY OPTION BOARD no on bypass signal PIN JUMPER ASSIGNMENT FOR THE FALCON UA88376 RELAY OPTION BOARD with on bypass signal DB 9F PIN JUMPER AS...

Страница 19: ...n for pins 2 3 5 5 Low Battery N O Closes at low battery 6 Remote Shutdown Applying a 5 12Vdc voltage level for 500ms while the UPS is on battery will shutdown the UPS 7 Not Used 8 Not Used 9 Not Used...

Страница 20: ...see page 20 for contact information Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servicing of batteries should be performed or supervised...

Страница 21: ...cause interference to radio and television reception All models covered in this manual have been tested and found to comply with the limits for a Class A computing device in accordance with the specif...

Страница 22: ...d when returning any SG Series product Falcon Electric will not assume any responsibility for shipping damage In the event of shipping damage you will be notified of the damage and be instructed to fi...

Страница 23: ...OF MERCHANTABILITY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND EXPRESS WARRANTIES THAT THIS PRODUCT WILL CONFORM TO ANY AFFIRMATION OR PROMISE FOR THIS PRODUCT AND THE USER AGREES THAT IN...

Страница 24: ...oling Low Velocity Forced Air Fans Audible Noise 1 Meter 55dBA Controls and Indicators LED Line Inverter Battery Reserve Load Bypass Alarm Crest Battery Load Capacity Level Audible Alarms DC Mode Low...

Отзывы: