background image

 

3.5 FLAME FAILURE THERMOCOUPLE 

The sensing tip should be mounted 2.5mm (max.) below burner plaques for robust 
operation. The tip must not touch any nearby surface. 
a) Remove upper front facia and control panel as detailed in Sections 3.2. 1 and 3.2.2. 
b) Undo nut that secures thermocouple to bracket. 
c) Undo nut that secures thermocouple to gas tap. 
d) Withdraw thermocouple and replace.  
 

3.6  GAS TAP 
 
3.6.1  Servicing 

To Remove the control, proceed as follows: 
a) Pull control knobs off and remove control panel as detailed in Section 3.2.1. 
b) Undo nut securing burner feed pipe to control. 
c) Remove bolts that secure control to gas pipe. 
d) Manoeuvre control to enable thermocouple to be removed. 
e) Withdraw control. When replacing, ensure sealing gasket is in a serviceable condition and 
check gas soundness. 
To Clean and Re-grease 
f) Remove fixings which retain niting cover. At same time, hold cover against internal spring 
pressure. 
g) Carefully withdraw niting cover complete with operating spindle. 
h) Withdraw exposed rod, spring, brass and sealing washer. Be careful not to lose any parts. 
j)  Withdraw plug and clean with a soft rag. Also clean mating surfaces in control body. 
Sparingly  re-grease plug with an approved heat resistant grease. 
Re-assemble in reverse order taking care with central pin assembly. Fit spring to pin first, 
then brass washer and finally sealing washer.  
Ensure sealing washer fits snugly into recess plug bottom and when re-fitting operating 
spindle, that niting pin engages in plug slot. 
 

3.6.2  Adjusting Low Flame Setting 

The LOW FLAME setting is adjustable by means of a screw on front of control. If it is 
necessary to adjust flame, adopt the following procedure. 
a) Turn adjusting screw fully clockwise as far as it will go and unscrew it a quarter to a third 
of a turn. 
b) Light one pair of burners. Turn control to LOW FLAME setting. Consult User instructions 
for lighting procedure. 
c) Carefully adjust screw for satisfactory operation. Turn screw anti-clockwise to increase 
flame and clockwise to decrease it.  
d) Pressures for low flame settings are indicated in table below. The test points located 
closest to burner injectors should be used. These can be found directly behind rear panel. 

Note 

These values refer to a condition with only one burner (pair) lit in LOW position. 
 

MODEL 

Natural  

Propane  

G1528 

7 mbar 

20 mbar 

 
Refer to Section 1.9 for full flow pressure. 
 
 
 

 

 

  

   Low flame Setting Screw 

 
 

 
 
 
 

Содержание STEAKHOUSE PLUS G1528

Страница 1: ...ructions should be left with the Engineer in Charge for reference during servicing Further to this the Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN...

Страница 2: ... Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems due to cus...

Страница 3: ...removal of combustion products and cooking vapours which may be harmful to health This appliance is to be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room which they are installed The fresh air requirement for this appliance at a rate of 1M hour per kW is 13 1 M of fresh air per hour Care must be taken not to...

Страница 4: ...n this appliance 1 7 TOTAL RATED HEAT INPUT Natural I2h Propane I3p Control position Kw nett Btu hr gross Kw nett Btu hr gross G1528 Full 13 1 49 000 13 1 49 000 G1528 Turndown low Per burner pair 4 9 18 400 4 9 18 400 1 8 INJECTOR SIZES NATURAL and PROPANE GAS MODEL Main Burner Nat I2h Main Burner Prop I3p X lighter Nat I2h X lighter Prop I3p G1528 4 x Amal 300 4 x Amal 110 2 x R shaw 22 2 x R sh...

Страница 5: ...l Unit Unpack grill unit and check that all components are undamaged Parts supplied loose 1 off each are as specified in the contents list below Brander Drip Trough Brander Wire Grid Drip Tray Gas Governor Natural Gas Only Flue Diverter Appliance Mounting Accessories The mounting method will have been decided at time of ordering The option chosen will be supplied in a separate pack or carton GRILL...

Страница 6: ...Figure 1 ...

Страница 7: ...Shakeproof Washers 4 D A C B E a Fix both shelves B to end supports A C using M5 screws provided b Fix front skirt D to end supports A C using M5 screws provided c Screw adjustable feet into sockets in end supports and level stand d Lift grill upon stand Secure using four M6 screws provided through holes in front skirt and end support lugs e Holes are provided in stand foot pads to facilitate floo...

Страница 8: ...racket against wall in desired position Ensure top surface is horizontal in both directions Use bracket as a template to mark fixing hole positions Drill and plug wall to accommodate fixture of bracket Having secured bracket in position place unit upon it and secure by locating base holes Secure through bracket into base of grill Diverter prevents droplets falling into burner NO FLUE DIVERTER FITT...

Страница 9: ...ace test point sealing screw ensuring a gas tight joint is made Re assemble all panels and components removed during installation and commissioning Also place drip tray wire grid flue diverter and brander plate in position 2 6 INSTRUCTION TO USER Hand over user instructions and ensure that operator understands the procedure for lighting cleaning and correct use of the grill Point out location of t...

Страница 10: ... slightly at rear and withdraw rearward from front locating pins Replace in reverse order To remove RH side undo two top and bottom fixings and withdraw 3 2 4 Rear Panel and Chamber a Remove top panel as detailed in Section 3 2 3 b Undo internal top fixings and those in lower exterior to remove outer panel c The lower inner panel will slide out toward rear d Replace in reverse order 3 3 BURNERS 3 ...

Страница 11: ...lean with a soft rag Also clean mating surfaces in control body Sparingly re grease plug with an approved heat resistant grease Re assemble in reverse order taking care with central pin assembly Fit spring to pin first then brass washer and finally sealing washer Ensure sealing washer fits snugly into recess plug bottom and when re fitting operating spindle that niting pin engages in plug slot 3 6...

Страница 12: ...spares always quote appliance type and serial number This information will be found on data badge attached to appliance 537210660 Burner Assembly 537210670 Burner Guard 537550360 Control Valve 531880520 Control Knob 531720060 Pilot Burner Assy Nat Gas 537220270 Burner Injector Nat Gas 537220450 Burner Injector Propane 537220330 Thermocouple 531532190 Grid Handle 531532200 Grid Handle Disc 53590001...

Отзывы: