3.5 FLAME FAILURE THERMOCOUPLE
The sensing tip should be mounted 2.5mm (max.) below burner plaques for robust
operation. The tip must not touch any nearby surface.
a) Remove upper front facia and control panel as detailed in Sections 3.2. 1 and 3.2.2.
b) Undo nut that secures thermocouple to bracket.
c) Undo nut that secures thermocouple to gas tap.
d) Withdraw thermocouple and replace.
3.6 GAS TAP
3.6.1 Servicing
To Remove the control, proceed as follows:
a) Pull control knobs off and remove control panel as detailed in Section 3.2.1.
b) Undo nut securing burner feed pipe to control.
c) Remove bolts that secure control to gas pipe.
d) Manoeuvre control to enable thermocouple to be removed.
e) Withdraw control. When replacing, ensure sealing gasket is in a serviceable condition and
check gas soundness.
To Clean and Re-grease
f) Remove fixings which retain niting cover. At same time, hold cover against internal spring
pressure.
g) Carefully withdraw niting cover complete with operating spindle.
h) Withdraw exposed rod, spring, brass and sealing washer. Be careful not to lose any parts.
j) Withdraw plug and clean with a soft rag. Also clean mating surfaces in control body.
Sparingly re-grease plug with an approved heat resistant grease.
Re-assemble in reverse order taking care with central pin assembly. Fit spring to pin first,
then brass washer and finally sealing washer.
Ensure sealing washer fits snugly into recess plug bottom and when re-fitting operating
spindle, that niting pin engages in plug slot.
3.6.2 Adjusting Low Flame Setting
The LOW FLAME setting is adjustable by means of a screw on front of control. If it is
necessary to adjust flame, adopt the following procedure.
a) Turn adjusting screw fully clockwise as far as it will go and unscrew it a quarter to a third
of a turn.
b) Light one pair of burners. Turn control to LOW FLAME setting. Consult User instructions
for lighting procedure.
c) Carefully adjust screw for satisfactory operation. Turn screw anti-clockwise to increase
flame and clockwise to decrease it.
d) Pressures for low flame settings are indicated in table below. The test points located
closest to burner injectors should be used. These can be found directly behind rear panel.
Note
These values refer to a condition with only one burner (pair) lit in LOW position.
MODEL
Natural
Propane
G1528
7 mbar
20 mbar
Refer to Section 1.9 for full flow pressure.
Low flame Setting Screw
Содержание STEAKHOUSE PLUS G1528
Страница 6: ...Figure 1 ...