background image

Turn off gas control tap, remove pressure gauge and

replace the test point sealing screw ensuring a gas

tight joint is made.
Re-assemble all panels and components removed

during installation and commissioning, also place drip

tray, wire grid and brander plate in position.

2.6 INSTRUCTION TO USER
Hand over the User's Instructions and ensure that the

user understands the instructions for lighting,

cleaning and correct use of the appliance. Point out

the location of the gas isolating cock which may

require to be used in an emergency.
Advise the User that the grill unit and its installation

should be serviced and inspected regularly as

recommended by the local Gas Region, for

continuing safe and efficient operation.
Inform the User also, that any smell emitted from the

new appliance should disappear quickly.
It is also be pointed out that overhead extraction unit

filters and their respective drip trays must be

maintained in good condition. Excessive fat deposits

which collect are a serious fire risk to underlying units

as hot fat may drip down and catch fire.

SECTION 3 - SERVICING and

COMMISSIONING

General Note
Before carrying out any inspection, servicing or

exchange of gas carrying components, TURN OFF

GAS AT THE ISOLATING COCK and remove the

brander plate and toast grid.
When re-assembling, replace the parts in the reverse

order to dismantling, unless otherwise specified.
After carrying out any servicing or exchange of gas

carrying components -
ALWAYS TEST FOR GAS SOUNDNESS.

3.1 GAS CONVERSION CHECK LIST
To convert from NATURAL to PROPANE gas -
Change Injectors
Adjust Low Flame setting
Remove the governor and adjust the inlet pressure

accordingly
Change Data Plate
To convert from PROPANE to NATURAL gas -
Change Injectors
Adjust the low flame setting
Add the governor and adjust the inlet pressure

accordingly
Change Data Plate
For detailed procedures, refer to the appropriate

sections of this document.

3.2 REMOVAL OF PANELS
3.2.1 Control Panel
Undo the fixing at the panel base and ease the panel

outward at the bottom then downward to release the

top locating pins. Replace in reverse order.
3.2.2 UpperFront Facia
This is removed by taking away the control panel as

detailed in Section 3.2.1.
Undo the two fixings at the panel base and ease it

outward before raising to clear the top edge. Replace

all parts in reverse order.
3.2.3 Top and RH OuterSide Panel
Remove the three fixings located at the rear of the

flue outlet grille. Lift the panel slightly at the rear and

withdraw rearward from the front locating pins.

Replace in reverse order.
To remove the RH side, undo the two top and bottom

fixings and withdraw.
3.2.4 RearPanel and Chamber
a) Remove the top panel as detailed in Section 3.2.3.
b) Undo the internal top fixings and those in the lower

exterior to remove the outer panel.

c) The lower inner panel will slide out toward the rear.
d) Replace in reverse order.

3.3 BURNERS
3.3.1 To Remove The Main Burner
a) Remove the top panel as detailed in Section 3.2.3.
b) Lift out the burner flue guide.
c) Unhook the plaque guard noting that the guard is

not symmetrical with respect to locating hooks.

d) Undo the three fixings which secure the burner

tube to the back plate. Take care to retain the

aluminium sealing rings.

e) Pull the burners forward so the burner retaining

clips clear the fixing within the front burner support.

f) Replace all components in reverse order. Ensure

that the burner retaining clips are correctly loacted

at the front end.

3.3.2 To Remove The

Cross Lighting Burner (G1528 only)

a) Remove the top panel as detailed in Section 3.2.3.
b) Disconnect compression joint on gas supply pipe

to cross-lighter.

c) Undo the fixings which secure the cross-lighter

bracket to the back plate. Remove the burner.

d) Pull out the jet.
e) Replace in reverse order.

3.4 TO REMOVE MAIN BURNER INJECTOR
a) Remove the burner as detailed in Section 3.3.1.
b) Unscrew the injector and withdraw.

All manuals and user guides at all-guides.com