Turn off gas control tap, remove pressure gauge and
replace the test point sealing screw ensuring a gas
tight joint is made.
Re-assemble all panels and components removed
during installation and commissioning, also place drip
tray, wire grid and brander plate in position.
2.6 INSTRUCTION TO USER
Hand over the User's Instructions and ensure that the
user understands the instructions for lighting,
cleaning and correct use of the appliance. Point out
the location of the gas isolating cock which may
require to be used in an emergency.
Advise the User that the grill unit and its installation
should be serviced and inspected regularly as
recommended by the local Gas Region, for
continuing safe and efficient operation.
Inform the User also, that any smell emitted from the
new appliance should disappear quickly.
It is also be pointed out that overhead extraction unit
filters and their respective drip trays must be
maintained in good condition. Excessive fat deposits
which collect are a serious fire risk to underlying units
as hot fat may drip down and catch fire.
SECTION 3 - SERVICING and
COMMISSIONING
General Note
Before carrying out any inspection, servicing or
exchange of gas carrying components, TURN OFF
GAS AT THE ISOLATING COCK and remove the
brander plate and toast grid.
When re-assembling, replace the parts in the reverse
order to dismantling, unless otherwise specified.
After carrying out any servicing or exchange of gas
carrying components -
ALWAYS TEST FOR GAS SOUNDNESS.
3.1 GAS CONVERSION CHECK LIST
To convert from NATURAL to PROPANE gas -
Change Injectors
Adjust Low Flame setting
Remove the governor and adjust the inlet pressure
accordingly
Change Data Plate
To convert from PROPANE to NATURAL gas -
Change Injectors
Adjust the low flame setting
Add the governor and adjust the inlet pressure
accordingly
Change Data Plate
For detailed procedures, refer to the appropriate
sections of this document.
3.2 REMOVAL OF PANELS
3.2.1 Control Panel
Undo the fixing at the panel base and ease the panel
outward at the bottom then downward to release the
top locating pins. Replace in reverse order.
3.2.2 UpperFront Facia
This is removed by taking away the control panel as
detailed in Section 3.2.1.
Undo the two fixings at the panel base and ease it
outward before raising to clear the top edge. Replace
all parts in reverse order.
3.2.3 Top and RH OuterSide Panel
Remove the three fixings located at the rear of the
flue outlet grille. Lift the panel slightly at the rear and
withdraw rearward from the front locating pins.
Replace in reverse order.
To remove the RH side, undo the two top and bottom
fixings and withdraw.
3.2.4 RearPanel and Chamber
a) Remove the top panel as detailed in Section 3.2.3.
b) Undo the internal top fixings and those in the lower
exterior to remove the outer panel.
c) The lower inner panel will slide out toward the rear.
d) Replace in reverse order.
3.3 BURNERS
3.3.1 To Remove The Main Burner
a) Remove the top panel as detailed in Section 3.2.3.
b) Lift out the burner flue guide.
c) Unhook the plaque guard noting that the guard is
not symmetrical with respect to locating hooks.
d) Undo the three fixings which secure the burner
tube to the back plate. Take care to retain the
aluminium sealing rings.
e) Pull the burners forward so the burner retaining
clips clear the fixing within the front burner support.
f) Replace all components in reverse order. Ensure
that the burner retaining clips are correctly loacted
at the front end.
3.3.2 To Remove The
Cross Lighting Burner (G1528 only)
a) Remove the top panel as detailed in Section 3.2.3.
b) Disconnect compression joint on gas supply pipe
to cross-lighter.
c) Undo the fixings which secure the cross-lighter
bracket to the back plate. Remove the burner.
d) Pull out the jet.
e) Replace in reverse order.
3.4 TO REMOVE MAIN BURNER INJECTOR
a) Remove the burner as detailed in Section 3.3.1.
b) Unscrew the injector and withdraw.
All manuals and user guides at all-guides.com