INSTALLATION CHECK LIST
Flue System
1.
Minimum Flue Height of 4.5 metres.
2.
Appliance should be connected to a minimum of 1.8 metres of 150mm.
flue pipe with a horizontal run not exceeding 150mm.
3.
Appliance should be connected to a chimney of less than 200mm in diameter
(otherwise the chimney must be lined with a 150mm flue liner).
4.
The chimney venting position must be above the apex of the roof or adjacent
outside obstructions.
5.
The chimney serving this appliance should not serve any other appliance.
6.
Access should be provided to the chimney serving the appliance to allow for cleaning.
Location
7.
Clearance to combustible materials must be adhered to as described in the Clearance
to Combustible section.
8.
The stove must be installed on a floor protector that covers the area under the stove
and extends 18” to the front & 6” to the sides and back.
Ventilation & Combustion Air Requirements
9.
The room in which the appliance is located should have an air vent of adequate
size to support correct combustion (see Ventilation & Combustion Air Requirement
Section for specific details).
Tick
11