4
B-2) Explanation of Programming Options
01) Chirp confirmation on/off: Factory default = On
The siren will chirp once to enter armed mode and twice to enter disarmed mode when
programmed as on. The siren will not chirp if programmed as off.
02) Shock Sensor Bypass: Factory default = Disabled
When programmed as Disabled: The shock sensor will work normally
When programmed as First: The 1
st
stage shock sensor will be bypass after 3 continual triggers
When programmed as Both: Both stages of the shock sensor will be bypassed after 3 continual
triggers.
03) Passive Arming: Factory default = Disable
When programmed as Disabled: The feature will not be activated
When programmed as Enabled: The LED will flash rapidly and system will enter the armed
mode automatically after 30 seconds of turning the ignition off and closing the last opened door,
the bonnet and boot. The siren will chirp and parking lights flash once to confirm and the
immobiliser turns on.
04) Passive Locking: Factory default = Disabled
When programmed as Disabled: The doors will not be locked when the passive arming feature is
activated.
When programmed as Enabled: The doors will be locked when the passive arming feature is
activated.
05) Ignition lock: Factory default = Disabled
When programmed as Disabled: The doors will not be locked when turning the ignition on and
will not be unlocked when the ignition is off
When programmed as Enabled: The doors will be automatically locked 15 seconds after the
ignition is turned on and the doors will be unlocked immediately upon the
ignition being turned off
When programmed as Lock Only: The doors will be locked 15 seconds after turning the ignition
on but will not be unlocked after turning the ignition off.
06) Door lock time: Factory default = 1 Pulse
When programmed as 1 Pulse: The system will send one 1 second pulse when locking or
unlocking the doors.
When programmed as 2 Pulse: The system will send one 1 second pulse when locking the doors
and two 1 second pulses when unlocking the doors.
When programmed as 4 sec.: The system will send one 4 second pulse when locking or
unlocking the door.
07) Siren/Horn: Factory default = Siren
When programmed as Siren: The system will send a constant output
When programmed as Horn: The system will send an intermittent output with a 0.5 second
interval between each output. An extra relay should be added if Horn is selected.
08) Alarm condition cycle duration: Factory default = 30 seconds.
To program the alarm time as 30 or 60 seconds.
09) Interior light delay: Factory default = Disabled
If the vehicle has a delay on turning off the interior light when closing the door, set the Interior
Light Delay to 15 or 40 Secs.