background image

SECTION 4 - SPARE PARTS

When ordering spares, always quote the appliance type

and serial number. 

This information will be found on the data plate.

3.3  THERMOSTAT

To remove thermostat, proceed as follows:-

a) Tilt griddle plate up and remove thermostat phial as

detailed in Section 3.1.2.

b) Undo nut fixing burner feed pipe to control.

c) Remove thermocouple nut.

d) Remove pilot pipe from control.

e) Remove bolts retaining control to float rail.

f ) Manoeuvre control to removal pilot tubing nut.

g) Withdraw thermostat and phial.

Replace thermostat and re-assemble in reverse order.

When replacing control, ensure sealing gasket is in a

serviceable condition and check for gas tightness.

To clean and lubricate tap, proceed as follows:-

Note

- Plugs and bodies are machined in pairs and are

therefore not interchangeable. Always clean one tap at a

time.

g)  Remove front securing plate fixings while holding plate

against internal spring pressure.

h) Withdraw plate carefully, complete with operating

spindle.

j)  Withdraw exposed rod, spring, brass washer and

sealing washer, taking care not to lose any small parts.

k)  Withdraw plug and clean with a soft rag. Also wipe

mating hole in control body. Ensure grease does not

block plug hole and in particular the holes within tap

body as this may reduce gas rate. 

Sparingly regrease plug with an approved heat resistant

grease. Re-assemble strictly in reverse order, taking care

with central pin assembly i.e. fit spring to pin first then

brass washer and finally rubber sealing washer.

When inserting into plug, ensure sealing washer fits

snugly into recess in bottom of hole in plug.

When reassembling operating spindle, ensure niting pin

engages in plug slot. When replacing control, ensure

sealing gasket is in a serviceable condition and check for

gas soundness. Take care not to bend thermocouple

capillary to less than 12mm radius.

3.7  GOVERNOR

This applies to NATURAL GAS APPLIANCES ONLY.

The type of governor supplied is maintenance free.

Check blue dust cap that covers vent is fitted and in good

condition as this protects breather hole.

Содержание G3441

Страница 1: ...uld be handed over to the User having had a demonstration of the operation and cleaning of the Appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING T...

Страница 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Страница 3: ...rface counter top or alternatively on the purpose made stand supplied by Falcon Installation should be made in accordance with local and or national regulations applying at the time A competent instal...

Страница 4: ...Model Natural Gas Propane Gas G3441 No 36 No 19 G3641 No 36 No 19 G3941 No 36 No 19 1 9 1 Natural Gas Burner Pressure Natural gas appliances are supplied with an adjustable governor this should be se...

Страница 5: ...mergency is demonstrated Advise User that unit and installation should be SERVICED and INSPECTED REGULARLY as recommended on title page of this document SECTION 2 ASSEMBLY and COMMISSIONING 2 1 ASSEMB...

Страница 6: ...ntrol panel as detailed in Section 3 1 b Undo fixings for griddle plate capping channel and remove capping channel c Lift griddle from seal and pull it forward approx 50mm d Tilt front of plate up and...

Страница 7: ...thdraw plate carefully complete with operating spindle j Withdraw exposed rod spring brass washer and sealing washer taking care not to lose any small parts k Withdraw plug and clean with a soft rag A...

Страница 8: ......

Отзывы: