OFF
HEAT
TILT
Manual operation handle
(G2965/95 only)
Manual operation
mechanism
(G2965/95 only)
Piezo igniter
Gas control
HAND TILTING
UP
DOWN
Tube
Tilt Switch
A safety tilt switch operates when pan is raised from
fully horizontal position to shut off gas to main burner.
If main burner comes on or remains on when pan is
raised, the unit should be serviced by a qualified
engineer.
Tilt Operation (G2962 and G2994 only)
Use handwheel on front control panel to raise and
lower pan.
Tilt Operation (G2965 and G2995 only)
Change Over Switch
The switch controls operation or tilting of pan.
Figure 4
Foot Bellows
Two foot bellows are located on a swinging arm under
unit for raising or lowering pan. Pressure on either
bellows sends a signal to a pneumatically operated
microswitch which in turn operates lifting device.
Note: The drop down door must be closed to operate
the bellows.
FIgure 5
Electric Operations (see Figure 5)
The bellows are marked UP and DOWN and are
located below unit. The foot bellows should be swung
out to the front and allowed to drop to the floor.
The change-over switch should be set to tilt and pan
can then be raised o r lo wered by pressing the
appropriate bellow.
Light pressure is sufficient to operate the bellows.
Pressure should be removed from the UP bellow
when pan is fully raised and from the DOWN bellow
when fully lowered. Maintaining pressure under such
circumstances can cause excessive clutch wear.
When tilting pan to empty, watch that contents pour
from the lip and stop raising to stall pouring. Pouring
can be stopped by slightly lowering the pan.
The mechanism is fitted with a thermal overload.
Excessive raising and lowering will cause this to cut
out. The overload is self re-setting and the
mechanism will be operational within approx.
1 minute. The overload should not cut out during
normal operation of the mechanism.
Hand Operation (See Figure 6)
The unit is equipped with a means of raising or
lowering pan by hand in the event of an electrical
failure of the tilting mechanism.
A handle is located behind the drop down door and
this should be inserted along the tube located to the
RH side behind door. Once handle engages in clutch,
anti-clockwise rotation will raise and clockwise lower
the pan.
This method of tilting is only intended for use in an
emergency and because of the high gearing, is slow.
Note: Electric tilting is not possible with drop down
door open.
Figure 6
SECTION 2 - LIGHTING and OPERATION
LIGHTING INSTRUCTIONS
The gas control valve is fitted with a safety interlock.
After pressing the OFF button on control, a period of
3 minutes will elapse before it is possible to light
burner.
Warning: If pilot flame is extinguished either
intentionally or otherwise, NO ATTEMPT should be
made torelight gas until at least 3 minutes have
elapsed.
1. Switch ON electricity supply topan. Ensure pan is
fully lowered. On G2965/95 models only,
set changeover switch to heat.
2. Press and hold gas control pilot button in while
repeatedly pressing and releasing igniter button
until pilot lights. Check through sight hole.
3. Keep pilot button pressed in fully for a further
20 seconds before release. Pilot should remain lit
but if it goes out, push gas control OFF button in
and wait for three minutes. Repeat from Step 2.
4. Push gas control main burner button to right.
5. Set thermostat to desired setting. Main burner will
now light