Falcon G2962 Скачать руководство пользователя страница 3

OFF

HEAT

TILT

Manual operation handle

(G2965/95 only)

Manual operation

mechanism

(G2965/95 only)

Piezo igniter

Gas control

HAND TILTING

UP

DOWN

Tube

Tilt Switch
A safety tilt switch operates when pan is raised from

fully horizontal position to shut off gas to main burner.

If main burner comes on or remains on when pan is

raised, the unit should be serviced by a qualified

engineer.
Tilt Operation (G2962 and G2994 only)
Use handwheel on front control panel to raise and

lower pan.
Tilt Operation (G2965 and G2995 only)
Change Over Switch
The switch controls operation or tilting of pan.

Figure 4
Foot Bellows
Two foot bellows are located on a swinging arm under

unit for raising or lowering pan. Pressure on either

bellows sends a signal to a pneumatically operated

microswitch which in turn operates lifting device.
Note: The drop down door must be closed to operate

the bellows.

FIgure 5

Electric Operations (see Figure 5)
The bellows are marked UP and DOWN and are

located below unit. The foot bellows should be swung

out to the front and allowed to drop to the floor.
The change-over switch should be set to tilt and pan

can then be raised o r lo wered by pressing the

appropriate bellow.
Light pressure is sufficient to operate the bellows.
Pressure should be removed from the UP bellow

when pan is fully raised and from the DOWN bellow

when fully lowered. Maintaining pressure under such

circumstances can cause excessive clutch wear.
When tilting pan to empty, watch that contents pour

from the lip and stop raising to stall pouring. Pouring

can be stopped by slightly lowering the pan.
The mechanism is fitted with a thermal overload.

Excessive raising and lowering will cause this to cut

out. The overload is self re-setting and the

mechanism will be operational within approx.

1 minute. The overload should not cut out during

normal operation of the mechanism.

Hand Operation (See Figure 6)
The unit is equipped with a means of raising or

lowering pan by hand in the event of an electrical

failure of the tilting mechanism.
A handle is located behind the drop down door and

this should be inserted along the tube located to the

RH side behind door. Once handle engages in clutch,

anti-clockwise rotation will raise and clockwise lower

the pan.
This method of tilting is only intended for use in an

emergency and because of the high gearing, is slow.
Note: Electric tilting is not possible with drop down

door open.

Figure 6

SECTION 2 - LIGHTING and OPERATION

LIGHTING INSTRUCTIONS
The gas control valve is fitted with a safety interlock.

After pressing the OFF button on control, a period of

3 minutes will elapse before it is possible to light

burner.
Warning: If pilot flame is extinguished either

intentionally or otherwise, NO ATTEMPT should be

made torelight gas until at least 3 minutes have

elapsed.
1. Switch ON electricity supply topan. Ensure pan is

fully lowered. On G2965/95 models only,

set changeover switch to heat.

2. Press and hold gas control pilot button in while

repeatedly pressing and releasing igniter button

until pilot lights. Check through sight hole.

3. Keep pilot button pressed in fully for a further

20 seconds before release. Pilot should remain lit

but if it goes out, push gas control OFF button in

and wait for three minutes. Repeat from Step 2.

4. Push gas control main burner button to right.
5. Set thermostat to desired setting. Main burner will

now light

Отзывы: