background image

Model

 

kW

 

Btu/hr

 

G1808X Fryer

 

16.7

 

57,000

 

G1838X Fryer

 

30

 

102,360

 

G1848X Fryer

 

2 x 16.7

 

2 x 57,000

 

 

SECTION 1 - INSTALLATION

 

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER 

ARE NOT TO BE ADJUSTED BY THE INSTALLER.

 

1.1 MODEL NUMBERS, NETT WEIGHTS 

and DIMENSIONS

 

 

Model

 

Width

 

(mm)

 

Depth

 

(mm)

 

Height

 

(mm)

 

Weight

 

(kg)

 

G1808X Fryer

 

300

 

850

 

925

 

64

 

G1838X Fryer

 

600

 

850

 

925

 

92

 

G1848X Fryer

 

600

 

850

 

925

 

116

 

 

 

1.2 SITING

 

The unit should be installed on a level, fireproof surface 

in a well lit, draught free position. A clear space of 150mm 

should be left between the rear and sides of the fryer and 

any combustible wall.

 

If  the  floor  is  constructed  of  combustible    material, 

then local fire requirements should be checked to ensure 

compliance.

 

Important

 

If appliance is to be installed in suite formation with other 

matching  units,  the  instructions  for  all  models  must  be 

consulted to determine the necessary clearances to any 

combustible rear wall or overlying surface. Some models 

require  greater  clearances  than  others  and  the  largest 

figure  quoted  in  individual  instructions  will  therefore 

determine  clearance  of  complete  suite  adjoining 

appliances.

 

 

1.3 VENTILATION

 

Adequate ventilation must be provided to supply sufficient 

fresh air for combustion. This should allow easy removal 

of combustion products which may be harmful to health.

 

Recommendations for Ventilation of Catering Appliances 

are given in BS5440:2.

 

For multiple installations, the requirements for individual 

units require to be added together. Installation should be 

carried  out  in  accordance  with  local  and/or  national 

regulations which apply at the time. A competent installer 

MUST be employed.

 

1.4 GAS SUPPLY

 

The incoming service must be of sufficient size to supply 

full rate gas without excessive pressure drop. A gas meter 

is  connected  to  the  service  pipe    by    Gas    Supplier. 

Any existing meter should be checked by the supplier to 

ensure  that  it  is  of  adequate  capacity  to  pass  required 

rate  of  gas  for  the  unit,  in  addition  to  any  other  gas 

equipment that has been installed.

 

The  multifunctional  control  has  no  in-built  governor 

therefore an external device must be fitted to natural gas 

models.

 

Installation pipework should be fitted in accordance with 

IGE/UP/2.  This  should  not  be  smaller  than  gas  inlet 

connection.

 

G1808X 

- Rp½ 

(½" BSP) 

G1838X 

- Rp¾ 

(¾" BSP) 

G1848X 

- 2 x Rp½ 

(½" BSP)

 

An  inlet  manifold  is  supplied  with  the  G1848X  to  enable 
c o n n e c t i o n   t o   1  x  Rp¾ 

(¾"  BSP) 

mains  inlet  (if 

required). 

If flexible tube is used, the gas supply tubing or hose shall 

comply  with  national  requirements  in  force.  These 

should  be  periodically  examined  and  replaced  as 

necessary.

 

An  isolating  cock  must  be  located  close  to  the  unit  to 

allow  shutdown  during  an  emergency  or    servicing. 

The installation should be checked for gas tightness and 

purged as specified in IGE/UP/1.

 

 

1.5 ELECTRICAL SUPPLY

 

Not applicable to these units.

 

 

 

1.6 WATER SUPPLY

 

Not applicable to these units.

 

 

1.7 TOTAL GAS RATES - 

NATURAL and PROPANE GAS

 

Содержание G1808X

Страница 1: ...left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the...

Страница 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Страница 3: ...of Catering Appliances are given in BS5440 2 For multiple installations the requirements for individual units require to be added together Installation should be carried out in accordance with local...

Страница 4: ...are used these must be fitted with a brake or locking device This should be accessible to operator from front or side 2 3 CONNECTION TO A GAS SUPPLY Gas supply piping and unit connection must be inst...

Страница 5: ...Burner Isolate main gas supply to unit Disconnect pilot supply pipe compression nut and remove pipe from pilot burner Withdraw injector Undo thermocouple retaining nut and remove thermocouple from pi...

Страница 6: ...ay now be removed Undo nuts that secure thermostat capillary to pan front From inside pan gently remove two nuts that secure safety thermostat bracket to pan base Release safety thermostat bulb from m...

Страница 7: ...SECTION 4 SPARES When ordering spare parts always quote unit type and serial number This information will be found on data badge on upper panel behind door...

Отзывы: