INSTALLATION INSTRUCTIONS
1.
Loosen screws ‘A’ and ‘B’.
2.
Turn screw ‘D’ anti-clockwise to extend
the outer spring bracket.
3.
Insert the rangehood into the cut out.
Ensure spring brackets are positioned on top
of cupboard base.
4.
Turn screw ‘C’ clockwise to align rangehood
with cupboard base. Do not over tighten.
5. Tighten screw ‘A’ by turning clockwise to lock
fixing bracket.
6.
Fit off ductwork as required.
7. To remove rangehood, turn screw ‘D’ clockwise.
8. An accessible 10A GPO is to provided near the
top RHS of the Rangehood for connection.
MODEL
MOTOR BOX SIZE
HOOD BASE SIZE
CUPBOARD BASE
MIN.
CUT OUT SIZE
FALUC801
235 x 780mm
275 x 800mm
290 X 810mm
245 x 785mm
FALUC1002
235 x 980mm
275 x 1000mm
290 x 1010mm
245 x 985mm
CUPBOARD CUT OUT DIMENSIONS
FALUC801 & FALUC1002
MOUNTING OPTIONS