![Falcon Elan 110 Dual Fuel Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/falcon/elan-110-dual-fuel/elan-110-dual-fuel_user-manual_3311455041.webp)
39
Australia
11. Technical Data
This cooker is designed for use on Natural Gas, although a conversion for LP (LPG X Propane (2.54kPa)) gas is available.
INSTALLER:
Please leave these instructions with the user.
DATA BADGE LOCATION:
Cooker back. The serial number is repeated on the badge below the left-hand oven door opening.
Country of Destination:
Australia
Test Pressures (quoted on the data badge)
Gas
Electric
Natural gas
1kPa
240V 50Hz
Propane
2.54kPa
Dimensions
Overall height
minimum 898mm
maximum 925mm
Overall width
1100mm
Overall depth
648mm
Minimum space above hotplate
650mm
Connections
Gas
Electric
Rp ½ at rear right
240V 50Hz
Ratings
Natural Gas 1.0kPa
Propane 2.54kPa
Hotplate
Input
Injector
Bypass
Input
Injector
Bypass
Marking
Size Ø
Marking
Marking
Size Ø
Marking
Wok burner
15MJh
-1
internal 112
1.12mm
90
15MJh
-1
internal 66
0.67mm
54
external 164
1.65mm
external 91
0.87mm
Large Burner
12.3MJh
-1
165
1.65mm
80
12.3MJh
-1
89
0.96mm
41
Medium Burners
6.2MJh
-1
115
1.15mm
56
6.2MJh
-1
67
0.68mm
33
Small Burner
3.7MJh
-1
92
0.92mm
48
3.3MJh
-1
48
0.50mm
25
Gas burner inputs based on Gross Calorific Value
Ovens
Left-hand Multi-
function Oven
Right-hand Fan Oven
Fan element
2.72kW
2.72kW
Top element
1.3kW
Browning Element
1.25kW
Bottom element
1.1kW
Grill
2.5kW
Maximum total electrical load at 240V 8.06kW (approximate total including oven lights, oven fan, etc.).
DocAUS.102-0004 - Technical data - 110DF