Falcon E3900i Скачать руководство пользователя страница 5

5

01

Pan 

detection

error

Use of unsuitable wok material

Re-set required

Defective coil

Use suitable wok. 

Switch unit off for 10 seconds, then on.

Engineer required.

User

Engineer

02

No coil 

current

Re-set required

Coil failure

Switch unit off for 10 seconds, then on.

Engineer required.

User

Engineer

03

Excessive

generator

temperature

Re-set required

Air flow / filter blocked

Excessive ambient temperature

Generator error

Switch unit off for 10 seconds, then on.

Clean filter/remove obstruction.

Ventilate working area.

Switch off. Allow to cool. Replace generator.

User

Engineer

04

Excessive

cooking 

zone 

temperature 

Re-set required

Wok empty or too hot

Wok base damaged

Faulty temperature sensor

(constantly recording ambient)

Switch unit off for 10 seconds, then on.

Check wok has not boiled dry or is empty.

Check/replace wok. 

Engineer required.

User

Engineer

05

Control 

failure

Faulty control or incorrect wiring

Switch unit off for 10 seconds.

Check control connections to generator.

Replace control assembly.

User

Engineer

06

Internal

temperature

of generator

excessive

Re-set required

Switch unit off for 10 seconds, then on.

Refer to Fault 03.

User

Engineer

07

Cooking

zone 

temperature

sensor

Reset required

Switch unit off for 10 seconds, then on

Check sensor connections. Replace coil

assembly. Refer to Fault 04.

User

Engineer

08

Mains supply

failure

Re-set required

Fault with mains supply

Switch unit off for 10 seconds, then on.

Check mains supply.

User

Engineer

09

N/A

N/A

N/A

Code

Error

Cause

Action

U / E