SECTION 3 - SERVICING

BEFORE ATTEMPTING ANY MAINTENANCE,

ISOLATE THE APPLIANCE AT THE MAIN SWITCH

AND TAKE STEPS TO ENSURE THAT IT IS NOT

INADVERTENTLY SWITCHED ON.
3.1 CONTROL PANEL - TO REMOVE
a) Drain pan by inserting drain pipe over a suitable

receptacle then pull out drain lever and move it to

the right.

b) Remove knob at drain valve lever end using a 6mm

spanner on lever and a 10mm spanner on knob.

c) Remove two screws in upper flange of facia panel

i.e. below front hob.

d) Move panel slightly forward at top until clear of hob

then lift panel slightly upward thus releasing lower

fixing and to remove panel.

3.2 CONTROL THERMOSTAT

and INDICATOR LAMPS

If these prove faulty they are not normally repairable

and must be replaced using the following procedures:
3.2.1 Control Thermostat
In order to replace control thermostat, it will be

necessary to remove unit from stand or table location.

Adopt the following procedure :
a) Drain pan(s).
b) Remove control panel as detailed in Section 3.1.
c) Note positions and remove wires.
d)

Using a 'stubby' pozi screwdriver, remove

thermostat from control panel.

e) Disconnect supply connections and remove fryer

from location to enable it to be turned on its side

later.

f) Remove element as detailed in Section 3.3.
g) Remove cover plate from element hinge block

through which thermostat capillary tube passes.

Manoeuvre tube and phial through moving hinge

tube.

h) From front, remove two fixings which secure base

plate and remove plate.

j)

Turn unit on to its side. Feed capillary tube and

phial through hole in base of hinge block and

remove thermostat.

k) Replace in reverse order. Take care that capillary

tube is well clear of element terminals.

m) Replace elements (see Section 3.3). Also replace

base and control panels.

n) Fill pan with oil and heat it up.

Carry out installation tests.

Note
When replacing a cotrol thermostat, fit existing

insulating sleeving over capillary tubing. Ensure that

no portion of tubing is exposed to possible contact

with live parts. Coil excess tube by wrapping it around

a suitable mandrel of approximately 25mm diameter.
3.2.2 Indicator Lamps
Remove control panel as detailed in Section 3.1.
Pull off lamp connections and undo nut that secures it

at rear. Remove lamp and replace in reverse order.

3.3 ELEMENT
To replace heating element proceed as follows:
a) Drain pan.
b) Remove basket support bar from element and fully

raise element.

c) Remove 10 pozidriv screws in underside of

element terminal box.

d) Remove element terminal box bottom cover plate.

This can be effected by prising up lower edge with

a screwdriver.

e) Lower element and remove element guard (4

screws). Also undo clips that secure thermostat

phial to element assembly.

f) Remove push-on element connections, first noting

their locations.

g) Remove two hex-headed screws which secure

element assembly to terminal box. Remove

element, taking care not to kink or otherwise

damage thermostat capillary tube.

Replace element in reverse order ensuring that oil

resistant gasket is fitted under element mounting

plate.
Note that thermostat phial is fitted in third hairpin of

element from left, clamps being applied to centres

of three element sheaths.

3.4 SAFETY THERMOSTAT
3.4.1 To Reset
In the event of a control thermostat failure that results

in overheating of oil, safety thermostat will interrupt

and switch off all power to elements.
To re-establish circuit, it will be necessary to reset

safety thermostat.
First allow fryer to cool, then remove control panel as

detailed in Section 3.1.
On single pan fryer (E350/38), safety thermostat is

reset by depressing tubular rod situated immediately

below drain valve.
In the case of the double pan fryer (E350/39), two

safety thermostats are located at rear of unit between

two pans.
Reach in and depress red reset button (left and right

thermostats appropriate to left and right pans).