When ordering spares, please quote the model

number, serial number and voltage, as stated on

the data plate.

3.1 CONTROL PANEL - To Remove
Remove fat drawer, located below control panel.
Remove two fixings in upper flange of facia panel.
Allow panel to drop down slightly to release lower

fixings. Remove panel.
Replace in reverse order.

3.2 THERMOSTAT - To Replace
Remove control panel as detailed in Sectuon 3.1.
In controls compartment top, there are a number of

fixings that secure plate in position, 2 on E350/34 and

4 on E350/35. Remove these and raise plate from

front. Prop it up with a suitable piece of wood.

Take care not to strain thermostat capillary tube.
Undotwofixings that secure thermo

stat phial

clamping plate and release phial.
Pull off connections to thermostat, noting locations

according to wire numbers. Pull off thermostat knob

and remove fixings below to release thermostat from

panel.
Feed capillary tube and phial forward through rear of

control compartment and remove assembly.
Replace in reverse order, taking care to fit insulating

sleeving over capillary before fitting thermostat.
Ensure that earth bonding connection is replaced

behind thermostat fixing lug. After fitting thermostat,

test unit using a low setting and check that amber

light goes out as thermostat opens.
Pull off connections to thermostat, noting locations.

3.3 PILOT LAMPS - To Replace
a) Remove control panel as detailed in Section 3.1.
b) Pull off lamp connections.
c) Remove nut securing lamp at rear and remove

lamp.

3.4. HEATING ELEMENTS - To Replace
a) Remove control panel as detailed in Section 3.1.
b) Prop up hotplate as described in Section 3.2.
c) Remove element connections.
d) Remove nuts securing element lagging boxes.
e) Remove clamping plates securing element.
When fitting a new element, ensure that it is properly

fixed to underside of hotplate, located by various

projections cast into plate.
Ensure that element earth connections are exactly as

they were before replacing element.