Warranty Policy Shortlist 

 

Warranty 

does not

 cover the following:- 

• Correcting faults caused by incorrect installation of a product. 

• Where an engineer cannot gain access to a site or a product. 

• Repeat commission visits. 

• Replacement of any parts where damage has been caused by misuse. 

• Engineer waiting time will be chargeable. 

• Routine maintenance and cleaning. 

• Gas conversions i.e. Natural to Propane gas. 

• Descaling of water products and cleaning of water sensors where softeners/ conditioners 

are not fitted, or are fitted and not maintained. 

• Blocked drains 

• Independent steam generation systems. 

• Gas, water and electrical supply external to appliance. 

• Light bulbs 

• Re-installing vacuum in kettle jackets. 

• Replacement of grill burner ceramics when damage has been clearly caused by misuse. 

• Where an engineer finds no fault with a product that has been reported faulty. 

• Re-setting or adjustment of thermostats when appliance is operating to specification. 

• Cleaning and unblocking of fryer filter systems due to customer misuse. 

• Lubrication and adjustment of door catches. 

• Cleaning and Maintenance  

• 

Cleaning of burner jets 

• 

Poor combustion caused by lack of cleaning 

• 

Lubrication of moving parts 

• 

Lubrication of gas cocks 

• 

Cleaning/adjustment of pilots 

• 

Correction of gas pressure to appliance. 

• 

Renewing of electric cable ends. 

• 

Replacement of fuses 

• 

Corrosion caused by use of chemical cleaners. 

Содержание Dominator Plus G3800

Страница 1: ...USERS INSTALLATION AND SERVICING INSTRUCTIONS GAS BRATT PAN G3800 and G3800DX T100753 Rev 3 Published 04 10 2012 DATE PURCHASED MODEL NUMBER SERIAL NUMBER DEALER SERVICE PROVIDER...

Страница 2: ...01438 363 000 SYMBOLS PLEASE READ THIS MANUAL This manual should be read carefully before operating installing or servicing the appliance WARNING Please pay particular attention to sections of the man...

Страница 3: ...Technical Data 9 6 0 DIMENSIONS CONNECTION LOCATIONS 10 7 0 INSTALLATION 11 7 1 Unpacking 11 7 2 Siting Clearances 11 7 3 Ventilation 12 7 4 Gas Supply Connection 12 7 5 Electric Supply Connection 12...

Страница 4: ...0 INTRODUCTION This appliance has been CE marked on the basis of compliance with the Gas Appliance Low Voltage and EMC Directives for the heat inputs gas pressures and voltages stated on the data pla...

Страница 5: ...is the responsibility of the Supervisor or equivalent to ensure that users wear SUITABLE PROTECTIVE CLOTHING and to draw attention to the fact that some parts will by necessity become VERY HOT and wi...

Страница 6: ...6 2 0 OPERATION 2 1 Controls...

Страница 7: ...er neon will go out and the ignition sequence begins again repeat this stage as necessary 6 When the desired temperature is reached the green neon will go out 7 If cooking a liquid based food ensure i...

Страница 8: ...ON Failure due to lack of proper cleaning is not covered by warranty BEFORE ANY CLEANING IS UNDERTAKEN ENSURE THE APPLIANCE IS UNPLUGGED FROM THE MAINS SUPPLY AND CANNOT BE INADVERTENTLY TURNED ON WAR...

Страница 9: ...atural Propane Injector diameters 3 3mm 2 0mm Pilot Injectors SIT 31 2 SIT 25 Supply Pressure mbar 20 37 Inches w g 8 14 8 Operating Pressure mbar 10 34 Inches w g 4 13 6 TECHNICAL DATA TABLE B HEAT I...

Страница 10: ...10 6 0 DIMENSIONS CONNECTION LOCATIONS...

Страница 11: ...igure given for individual appliances instructions If a Gully is used in the premises ensure there is a gap of 200mm between the gully and front of the appliance DO NOT directly connect the flue to an...

Страница 12: ...ith IGE UP 2 The pipe work should be of adequate size but not smaller than unit gas inlet connection i e Rp B S P An isolating cock must be located close by to allow shut down during an emergency or s...

Страница 13: ...elevant figures refer to section 5 2 1 Turn appliance on and ensure red neon illuminates 2 Turn water tap on and ensure it is working correctly without any leakage 3 Ensure the pan tilting handle is f...

Страница 14: ...TE Ensure gas supply is disconnected before commencing Only reconnect gas supply after all conversion work has been completed Burner and pilot Injectors a Remove front panel b Remove burner injector c...

Страница 15: ...ENSURE THAT IT PERFORMS CORRECTLY AND CARRY OUT ANY NECESSARY ADJUSTMENTS AS DETAILED IN COMMISSIONING Symbols on drawings denotes a pozi head screw requires removal denotes a flat head screw requires...

Страница 16: ...16 5 6 7 When removing the front fascia care should be taken not to damage the neon cables...

Страница 17: ...G THERMOSTAT The operating thermostat is located on the pan underside To replace remove the phial clamp from the underside of the pan by removing the two nuts Pull out thermostat phial and feed it dow...

Страница 18: ...TAT Safety thermostat is located on the underside of the pan Push the button protruding out from the bottom of the box to reset To replace remove as per the operating thermostat Pull out phial then re...

Страница 19: ...S Lift pan fully up to get access to the burner Access to the burner pipe is from the front of the appliance while the front panel is removed To replace the burner first the pipe must be removed The p...

Страница 20: ...20 9 1 Wiring Diagram...

Страница 21: ...21 9 2 Circuit Diagram...

Страница 22: ...r and clean if dirty Low mains gas pressure Check with gas supplier Gas supply isolated off Restore supply Check with gas supplier Amber neon lighting multiple times Air in gas pipes happens after dis...

Страница 23: ...s appliance we would recommend that a maintenance contract be arranged with SERVICELINE Visits may then be made at agreed intervals to carry out adjustments and repairs A quotation will be given upon...

Страница 24: ...ms Gas water and electrical supply external to appliance Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an...

Отзывы: