8.0 CONVERSION
8.1 GAS CONVERSION CHECK LIST
Change burner pressure at valve in accordance with section 5.2.
CHANGE
INJECTORS
CHANGE DATA PLATE
Ensure gas supply is disconnected before commencing. Only reconnect gas supply
after all conversion work has been completed.
Burner and pilot Injectors
a) Remove front panel.
b) Remove burner injector.
c) Unscrew pilot pipe from pilot assembly.
d) Remove pilot injector.
e) Fit new injectors.
f) Return pilot pipe to pilot assembly.
g) Replace front panel.