SECTION 1 -
GENERAL DESCRIPTION
This group of products consists of the following models.
G3150 Fusion Burner Range
G3150D Fusion Burner Range
G3150 Fusion Burner Boiling Top
Units are fitted with flame failure devices to shut off gas
supply to burners if flames are extinguished.
The oven is thermostatically controlled.
Controls
All taps are the safety type with fixed HIGH and LOW
settings. The markings are illustrated below.
Open Top & Fusion Burner Gas Tap
Figure 1
Oven Burner Tap
Figure 2
Each tap may be identified with the corresponding
burner.
Note
Spark ignition button is located on control panel.
SECTION 2 -
LIGHTING and OPERATIONS
Open Top
1. Ensure mains gas is turned on.
2. Press and turn knob to full flame position.
3. Light burner using taper or match and continue to hold
knob in for a further 20 seconds before release.
4. Burner should remain lit; if burner goes out return to
Step 1 and repeat ignition procedure.
5. When burner remains lit, turn knob to required
position.
To Shut Open Top Burner OFF
Turn knob to OFF position.
Using the Fryplate Accessory
Figure 3
The oven is thermostatically controlled.
Control knob markings are in degrees
celcius and the control is identified by
this symbol.
Figure 4
Figure 6
Important Note - Caution
This should only ever be used with hob burners on low
flame setting.
The plate locates across any of the 3 banks of front and
rear burners of the pan support casting.
A drain slot is located at plate front and a drainage tray
slides below this from either side.
Allow plate to cool prior to any handling. To remove or
replace fryplate, lift it on and away from desired location
as appropriate.